Anwendungshinweisen

Kontaktieren Sie uns

Automated ultrasonic testing (AUT) of girth welds with corrosion resistant alloys (CRAs) using the Evident PipeWIZARD

Introduction:

In today’s pipeline industry, corrosion resistant alloys (CRAs) are widely used to help protect pipelines that transport corrosive fluids. Various combinations of CRA materials and thicknesses are used. In many cases, the parent material of the pipe is carbon steel with a layer of CRA bonded to the inside. The weld that joins pipe segments together is also made of the CRA material.

Challenges of CRA weld inspection

When inspecting a weld with phased array pulse-echo or pitch-catch standard configurations, the ultrasonic beam rebounds at the bottom of the part so that the beam’s second leg passes through the weld bevel and cap area. However, when a CRA is bonded to the inside of the pipe, the alloy often has properties, such as grain structure and velocity, that differ from the pipe’s parent material. The layer of CRA creates mode conversions which make data analysis extremely difficult. To avoid the need of a rebound, a phased array probe with longitudinal waves can be set up to pulse on the opposite side of the weld bevel. However, CRAs are generally more attenuating, which results in a decreased signal-to-noise ratio and, consequently, poor beam penetration. In addition, the upper portion of the weld, with potential surface and sub-surface indications, remains uninspected.

Solution: Dual linear array probes to inspect CRA welds with the PipeWIZARD system

A dual linear phased array (DLA) probe can be fixed to the PipeWIZARD scanner and used to inspect the dissimilar welds (Figure 1). The required equipment includes:




Figure 1: Evident dual linear array probe configuration.

Advantages of the technique

DLA probe with the PipeWIZARD enables the complete and accurate inspection of welds in CRA clad pipelines. The chief advantages of this technique include:

Natural Gas Service Line Inspection Using Videoscopes
Figure 2: S-scan imaging of an indication in a CRA weld.

Conclusion

A dual linear phased array probe in quad configuration can be fixed to the PipeWIZARD scanner for efficient inspection of CRA pipelines with dissimilar girth welds. The probe and wedges enable complete coverage of the weld in one pass with simultaneous inspection on both sides. The data quality is improved since the weld is inspected using only the ultrasonic beam’s first leg, eliminating the need for rebound to inspect the weld. This also results in a better signal-to-noise ratio and better penetration.

Since various combinations of materials and thicknesses can be used for CRA, the optimum inspection technique must always be defined for each project. Detection and sizing accuracy limits can only be determined by trials, so we recommended performing tests on a calibration block of the same material as the pipeline that is going to be inspected. Evident will continue to provide advanced tools to support new challenges in the pipeline industry.

Verwandte Produkte

PipeWIZARD System

Das PipeWIZARD System ist ein automatisiertes Prüfsystem für Rundschweißnähte, das mit Phased-Array und konventionellem Ultraschall prüft. Es ist speziell für die Schweißnahtprüfung vor Ort unter extremen Bedingungen bestimmt, ob Offshore oder Onshore.