Anwendungshinweisen
Uranium Exploration, Pathfinders & Light Elements
Evident' DELTA range of Portable X-Ray Fluorescence (XRF) Analyzers continue to lead the way in real time, in-field geochemical analysis. Custom built for exploration and mining specific applications, the DELTA hosts a powerful 4W X-ray Tube coupled with an application optimized anode and silicon drift detector providing the lowest possible Limits of Detection (LOD's) in the shortest possible analysis times. With a workable LOD of 2-4 ppm for both Uranium Thorium, the DELTA provides unparalleled performance for the Uranium Explorer with quantification at or below the same level as the average crustal abundance for Uranium (typically around 2-4 ppm U)
The DELTA's 3-Beam Soil Mode provides both the power and flexibility to tailor your analytical requirements in line with the geochemical signatures of the deposit style you are searching for, with access to a range of over 30 analytes. Whether you are exploring for Calcretes, Phosphorites or Unconformity-related style Uranium mineralization, the DELTA arrives configured with an effective pathfinder element suite which includes P, V, Ni, As, Mo Base Metals plus the ability to analyze Light Elements with the addition of 2-Beam Mining Mode. This added versatility enables analysis of Whole Rock Litho-Geochemistry and Alteration assemblages and can include Mg, Al, Si, P, S, K, Ca in addition to standard Mining Mode elements.
| Summary Geochemical Signatures | |
| Deposit Type | Geochemical Signatures |
| Unconformity-related | Nl, Pb, Co, As, B, Mo |
| Sandstone | Mo, Se, Ti, S, Fe |
| Breccia Complex (IOCG) | Fe, Cu, Au, Ag, Ba, F & REE |
| Quartz-Pebble Conglomerate | Ti, Au, Ag, REE, Fe, S, PGE, Ni, Co |
| Calcretes (Surficial) | V |
| Phosphorite | P, F |
| Other Uranium Deposit Types Include: Vein, Intrusive, Volcanic & Caldera-related, Metasomatic, Collapsed Breccia Pipe, Lignite & Black Shales | |
| Table Source: ioGlobal Geochemistry Workshop - Oct 2008 | |
Ähnliche Produkte
DELTA Professional
Mit einem Silizium-Driftkammer-Detektor (SDD) und einer 4-W-Röntgenröhre sind die DELTA Professional RFA-Handanalysatoren in Bezug auf Geschwindigkeit, Nachweisgrenzen und Elementbereich sehr leistungsfähig. Sie analysieren die chemischen Elemente von Mg bis U in Legierungen und Erzen. Die DELTA Professional RFA-Handanalysatoren sind eine hervorragende wirtschaftliche Lösung.
DELTA RFA-Handanalysatoren für Bergbau und Geochemie
Die DELTA RFA-Handanalysatoren für Bergbau und liefern sofortige Ergebnisse, die helfen, den gesamten Verlauf, von der Erkundung über die Erz-/Verfahrenskontrolle bis zur Umweltnachhaltigkeit, zu bestimmen. Metalle, Mineralien und Verunreinigungen lassen sich so bereits vor Ort identifizieren. GPS-GIS-RFA erleichtert die Kartierung der Metallvorkommen, was Zeit und Kosten spart.