HST-X04
Die manuellen HST-X04 Scanner von Evident für die Prüfung mit der Laufzeit-Beugungsmethode (TOFD) stellen eine leistungsstarke, kostengünstige und vielseitige Lösung zum Prüfen von Schweißnähten dar.
- Lead Time: 10
Überblick
The Evident HST-X04 time-of-flight diffraction (TOFD) manual scanner offers an efficient, low-cost, and versatile weld inspection solution.
Applications
- Manually deployed single-axis scanner for use on plate, pipe, and curved surfaces
- Applicable to pipes, pressure vessels, storage tanks, and structural components
- Operates in any orientation, either on flat surfaces or on pipes up to 51-mm (2 in.) OD.
Data acquisition
- Permanent record of the results with the OmniScan®
- Ideal for position-related A-scan, B-scan, and echo-dynamic scan data collection
- Suitable for any system with 2 UT channels
Scanner Kit Components
- Scanner with 150-mm frame
- Two 10-MHz (3-mm element diameter) CentraScan™ composite TOFD probes offering signal-to-noise ratio improvement over conventional UT probes
- Three sets of ST1 wedges with carbide wear pins and irrigation holes for 45º, 60º, and 70º operation
- Two LEMO®-Microdot® transducer cables 2.5m long
- Two LEMO®-to-BNC adapters
- Spring-loaded, friction-driven, and water proof Mini-Wheel encoder for X-axis or Y-axis data encoding
- Brackets for flexible encoder positioning
- Additional 250-mm frame for wider probe center separation
- Foam-padded carrying case
This HST-X04 Scanner kit can be further configured to fit the broad range of Evident TOFD and pulse-echo probes and wedges, including the composite product line.
Optional Preamplifier Kit
Part number: 5682-KIT01
The Panametrics 5682 preamplifier kit includes:
- 5682 preamplifier
- 2.5-m LEMO-LEMO cable
- Power cable
- 9 V battery
- Belt case
Preamplifier operates with standard 9 V battery or plugged to OmniScan® with supplied power cable.
Preamplifier specifications
- 30 dB gain
- 50 hours of battery life (continuous discharge)
- Continuous power-level indicator
- 67 dB signal-to-noise ratio
- Weight: 180 g (6.4 oz) with battery
- CE-certified
Merkmale
- Encoded linear-scan (one axis) for TOFD or pulse-echo inspections with appropriate yoke
- Water proof spring loaded encoder with rubber wheel for maximum adherence on inspected surfaces
- Compact, light and versatile
- Cost-effective
- Durable construction
- Can fit a full range of probes and wedges, including the CentraScan™ composite product line
- Probe center separation (PCS) fully adjustable from 17 mm to 180 mm
- Low-profile frame for use in constrained areas
- Tool-free quick release of wedges and probe holders
- Encoder resolution: 12 step/mm
- Compatible with the OmniScan, the TomoScan FOCUS LT (with optional adapter), and other instruments using the appropriate encoder cable (not included).