Handheld XRF's are used to test drywall quickly and easily without moving or destroying it. Drywall Detectors, LLC2 use Handheld XRF to compare levels of Strontium (Sr) and Sulfur (S) in domestic and imported drywall. They reported results for domestic (gray) drywall at levels less than 1,000 ppm for Strontium and at levels less than 1% for Sulfur; while defective Chinese drywall (blue) had elevated levels of Strontium at levels greater than 2,000 ppm and Sulfur with levels at or greater than 2%. Our Handheld XRF can measure up to 25 elements in a single test, including Sr, S, Fe, Ag, Cu and more.
XRF Testing of Drywall is Simple, Fast and Non-Destructive
Drywall Detectors tested intact drywall, defined as drywall that has undisturbed paper, intact on both sides. Essentially, it is tested as it was manufactured. For accuracy, they recommend testing a one square inch patch clear of paint and/or wallpaper. In most cases vent covers, outlets, attics and other unfinished areas provide testable drywall paper; however, in cases where they are not, the patch can be cleaned by scrapping, sanding or wire brushing.
1. Executive Summary, November 2009
2. www.drywalldetectors.com, Baltimore MD
Related products
DELTA Environmental Handheld XRF Analyzer
DELTA Environmental Handheld XRF Analyzers test for dangerously high levels of RCRA, Priority Pollutant and hazardous metals in seconds. HHXRF is used for soils and sediments according to EPA 6200 and other SOPs, filters per NIOSH or OSHA methods, screening surfaces and measuring dust wipes for Pb, Cd, Cr, As, Hg, and more.
DELTA Professional
Combining a Silicon Drift Detector (SDD) and a 4W optimized X-ray tube, the DELTA Professional provides superior performance in speed, LODs, and elemental range. It analyzes Mg and higher for Alloys and Mining. The DELTA Professional is the best value solution from Evident for handheld XRF.