The Race to Innovate—Borescopes Accelerate Automotive Research and Development

may-2022-bayard-morales-banner.jpg

Post Author's Photo

Bayard Morales

May 10, 2022

Modern borescopes, also called a videoscope as it uses an image sensor, are driving efficiency and improving research in the automotive industry.

One example is at the Institute for Advanced Automotive Propulsion Systems (IAAPS), where engineers are using specialized borescope equipment from Evident to perform visual inspections of internal combustion engines (ICEs) and other powertrain subsystems as part of their research and testing projects.

Dr. Andrew Lewis, IAAPS principal engineer, and Dr. Karl Giles, IAAPS senior engineer, recently met with me to discuss the key benefits and importance of using borescopes in automotive engine research and development. Check out our conversation below:

Q: Tell us about the partnership between IAAPS and Evident (now EVIDENT).

Andrew Lewis: It initially started as a regular supplier/customer relationship. We had another version of this type of visual equipment from a different company, which was a lot more basic and was giving us very poor images. One of our automotive clients recommended Evident, and we have been using their borescope since November 2020.

We have been working closely with Bayard and the team at Evident to learn the proper application of the system and how to get the best results out of this type of inspection for the research and testing that we conduct. From Evident's perspective, it is useful to see how a research facility like IAAPS is using their borescope in small, confined spaces such as the combustion chambers of passenger car engines, and it has been a very fruitful partnership so far.

Q: How is borescope inspection utilized within IAAPS and its research projects?

Andrew Lewis: A borescope is a remote optical device designed to assist the visual inspection of tight, difficult-to-reach cavities. It consists of a narrow, flexible probe with an articulating head at one end that houses the lens and image sensor, and a remote control for controlling the position of the articulating head at the other. It is a very capable piece of equipment, and the user has the option to fit a range of forward or side-facing lenses, depending on the requirements of the inspection being carried out.

Our device is 4 mm in diameter, so we can get into the really hard-to-reach places within an engine. The nature of our work means that we are often pushing the boundaries of what the engine can do, so it’s not uncommon for things to break or wear faster than normal. The Evident borescope allows us to observe what is going on inside an engine and detect any damage or wear before a catastrophic failure occurs.

Karl Giles: We predominantly use it for routine inspection of internal combustion engines. Using a borescope for this purpose is pretty standard practice, however it’s rare for engines outside of power generation and aviation to be inspected this way. The engines we work on are tiny in comparison to those used in power generation, which makes it much harder to get the shots you’re after because you’re working in much more confined spaces.

Besides petrol and diesel combustion chambers, we’ve also used the borescope to inspect turbochargers, diesel after-treatment systems, and the sump and heating elements of our new single cylinder rig. Basically, anywhere that’s hard to reach without significant disassembly!

Evident IPLEX™ GX/GT videoscope

Q: What are the benefits of the borescope equipment?

Karl Giles: We have learned a lot from using it. For instance, the results of our inspections have led us to take mitigating action to correct certain undesirable effects, prevent them from getting worse, or to guide the types of testing that we subsequently carry out. Essentially, it helps us identify issues early and take corrective action before anything breaks. The image quality is great, and we’ve never found we needed a higher resolution. The accessory set is pretty comprehensive, too, even though we actually get by with minimum accessories.

Andrew Lewis: The borescope inspection adds a significant visual aspect to our research and can help answer why data from test results may be looking differently or certain phenomena may be happening that we did not anticipate. There is always a trail of evidence that helps us to better understand our findings. Without it, we can only look at the numbers coming off our sensors for temperatures and pressures and so on. But being able to use the borescope gives us a visual indication and helps us interpret the results.

Furthermore, we are making significant efficiency gains and cost savings by using this type of internal inspection. Take the typical use-case of looking inside the combustion chamber itself. To do that without the borescope, you would have to physically strip off the front end of the engine, take all the systems apart, take the cylinder head off, etc. The quickest we could do that—with specialized tools—and rebuild the engine is two days, which is two days of downtime on that engine. However, this allows us to look in and be done within an hour. It’s a huge amount of time saved versus losing two days and potentially not seeing any results.

Q: What does this partnership mean for Evident?

Bayard Morales: For us, the most interesting part is to see how the borescope equipment for engine inspection is used in a research environment such as IAAPS. We can learn what works in its application, what doesn’t, and make changes accordingly. Ultimately, the idea behind the borescope is very simple: to see a part of the machinery without having to disassemble it. But it adds a lot of value to the research process.

Evident is by no means the only provider of this type of equipment, but I would consider ourselves the market leaders. We strive to improve and work closely with our clients so that they get the most out of our equipment. We focus on image quality because, at the end of the day, our customers need to be able to get high-resolution visuals to see inside and make decisions based on their findings. So, having this relationship with the engineers at IAAPS and their feedback is extremely valuable to us.

Q: The collaboration between IAAPS and Evident has resulted in a best practice guide. Can you give more details?

Bayard Morales: I realized that when we supplied IAAPS with the kit, there was no extensive guide on how to use the borescope for this particular application. As IAAPS has the knowledge on engines and we have the know-how on the borescopes, we thought it might be a good idea to start working on a best practice guide.

I spent an afternoon on-site at IAAPS with the engineers to see exactly how they are using it, and from that I took videos and notes, which will form the basis for a short manual. My initial aim was to train my own colleagues. But it turns out that it will be just as useful for IAAPS to have, as it will mean that any new members of staff will be able to quickly get to grips with the equipment, so we can share it between our organizations.

Karl Giles: We currently don’t have any formal instructions in place, and information is passed down via demonstrations, so it will be great to have a guide document or resource that we can point to when we train our colleagues. So far, we have had very positive feedback from our clients on the results of the inspection and the clarity of our photos, which is obviously a credit to Evident and their equipment but also to Bayard and the support that he has provided us. I’m sure the best practice guide will further cement this, and we can continue to build on our capabilities.

Andy Lewis: Let’s be honest, it is a considerable investment to have one of these borescopes, so you definitely don’t want to use it incorrectly because it could cost a lot to fix it. There are a lot of factors to consider to ensure safe operation of the borescope (engine temperature, for instance), so having all of those in one place would be very beneficial.

A close-up look at valves using Evident borescope equipment

Overview image of a piston captured using Evident borescope equipment

Q: As we move toward electrification, will borescope inspections remain relevant?

Karl Giles: Yes, I believe so. Downstream powertrain components, such as gearboxes and transmissions, are going to look quite similar regardless of whether they are being driven by an electric motor or an internal combustion. In an R environment like ours, there will always be a benefit to being able to inspect these subsystems without taking them apart. We haven’t had a huge amount of experience using the borescope in this capacity, but I would expect demand to grow as we see an increase in project work on electrified powertrain systems at the new IAAPS facility.

Andy Lewis: Yes, transmissions are always going to be around. Even if internal combustion engines die, gearboxes and transmissions will still have to work with electric machines, so there will be a requirement for internal inspections. In relation to electric machines, borescope inspection may take the form of physically looking inside a motor to inspect the windings for signs of thermal damage, for example.

As electric motors become increasingly powerful, there is going to be more complicated thermal management around them with integrated cooling galleries, etc. Inspection could therefore involve checking for any residue of coolant leaks or oil leaks within the motor. There is always going to be a need to see inside of a piece of equipment without disturbing it. That way you can be confident what you are seeing is not a result of the disassembly process. The more questions you can answer without disrupting the whole system, the better.

Nowadays, everyone is looking for efficiencies, and the cost of running a powertrain facility is very high. If you’re losing a day to disassemble and reassemble, that’s a huge expense. If you’re doing that every week because you’re breaking and inspecting components, that all adds up. If you can minimize that inspection time to half an hour because you can put a camera in there, well, borescopes will pay for themselves within a couple of weeks’ worth of testing.

Borescopes Drive Innovation in Automotive Research and Testing

Research and development teams in the automotive industry seek to accelerate the pace of innovation and drive the industry forward. This conversation demonstrates how modern borescopes can improve automotive R through high-quality imaging and efficient inspections.

Reposted with permission of IAAPS. View the original story here.

Post Author's Photo

Bayard Morales

Product Marketing Manager, Remote Visual Inspection

Bayard Morales is a product marketing manager at Evident specializing in remote visual inspection (RVI) technology. Bayard has 15 years of experience working with a wide range of industrial applications, including as a project engineer and product specialist in the fields of numerical simulation and industrial lubricants.