BondMaster Probe and Standard Kits
Please note that product availability varies by region. Contact your local Evident sales office for more information.
Part Number
U8 Number
Description
9323977
Q6700011
BondMaster Starter Probe and Reference Sample Kit. Contains: External Alarm Booster, VGA Cable, Screen Protectors (10 Pack), 600 Series Soft Instrument & Accesory Case, Couplant, Backing Foam, Probe, Pitch/Catch: S-PC-P14, Probe, MIA: S-MP-3, Probe, Resonance: S-PR-5, Reference Standard: NEC-6433, Reference Standard: NEC-6407, Reference Standard: NEC-6382, Reference Standard: NEC-6384, Teflon Tape (1 inch wide), Cable, Model SBM-CR-P6, Cable, Model SBM-CPM-P11, B600 Kit Case, capable of storing instrument with protective soft cover installed.
BM-KIT-PC1
U8010069
BondMaster probe and Standard Kit for Pitch-Catch Inspections, Contains: NEC-6407 Reference Standard with S-PC-P14 Ptich Catch probe and cable.
BM-KIT-PC2
U8010070
BondMaster probe and Standard Kit for Pitch-Catch Inspections, Contains: NEC-6407 Reference Standard with S-PC-P14 and SPO-5629PHV Pitch Catch probes and cable.
BM-KIT-MIA
U8010071
BondMaster Probe and Standard Kit for MIA Inspections, Contains: Contains: NEC-6407 Reference Standard with S-MP-3 MIA Probe and BMM-H Spring Holder and cable.
BM-KIT-RES-C
U8010072
BondMaster Probe and Standard Kit for Resonance Inspections, Contains: NEC-6382 Compositive Reference Standard with S-PR-4 Resonance probe, couplant and cable.
BM-KIT-RES-A
U8010073
BondMaster Probe and Standard Kit for Resonance Inspections, Contains: NEC-6384 Aluminum Reference Standard with S-PR-4, couplant and cable.
BM-KIT-PMR
U8010074
BondMaster Probe and Standard Kit for Pitch-Catch, MIA and Resonance Inspections, Contains: NEC-6407 Reference Standard, S-PC-P14 and SPO-5629PHV Pitch-Catch Probes, S-MP-3 MIA Probe with BMM-H Spring Holder, NEC-6382 Composite Reference Standard, NEC-6384 Aluminum Reference Standard S-PR-4 REsonance probe, couplant and cables.
Basic Probe Kit
9317813
Contains: S-MP-3 Standard size tip; BMM-H Probe housing; S-PC-P11 Pitch-catch probe; S-PR-4 165 kHz resonance probe; SBM-CPM-P11 Cable (P-C and MIA); SBM-CR-P6 Cable (resonance); Couplant (4 oz) for use with resonance probes; Probe case
Probe Kit
9317814
Contains: S-MP-3 Standard size MIA probe; S-MP-4 Small MIA probe; BMM-H probe housing; S-PC-P11 Pitch-catch probe; S-PR-3 110 kHz resonance probe; S-PR-5 250 kHz resonance probe; SBM-CR-P6 Cable (resonance); Couplant (4 ox) For use with resonance probes; Probe case
Deluxe Probe Kit
9322158
Contains: S-MP-3 Standard size MIA probe; S-MP-4 Small MIA probe; BMM-H Probe housing; S-PC-P11 Pitch-catch probe; S-PC-P12 Pitch-catch probe; S-PR-3 110 kHz resonance probe; S-PR-5 250 kHz resonance probe; SBM-CPM-P11 Cable (P-C and MIA); SBM-CR-P6 Cable (resonance); Probe case
Air Force Probe Kit
9322078
Contains: S-PR-1 35 kHz Resonance probe, S-PR-2 65 kHz Resonance probe, S-PR-3 110 kHz Resonance probe, S-PR-4 165 Resonance probe, S-PR-5 250 kHz Resonance probe, S-PR-6 330 kHz Resonance probe, S-PC-P1 Pitch-catch probe, low voltage; S-PC-P12 Pitch-catch probe, high voltage; S-MP-5 Internal spring MIA probe; SBM-CPM-P11 Cable (P-C and MIA), SBM-CR-P6 Cable (Resonance); Teflon Tape 1/4 in. wide roll; Couplant 4 oz. (For use with Resonance probes)