Conductivity Probes and Standards

Thickness and Flaw Inspection Solutions

Overview of Our Conductivity Probes

Conductivity probes are designed for sorting nonferrous metals and determining heat treatment condition or damage.

Our conductivity probes with Powerlink technology are designed to be used with the following NORTEC 600 series models: 600C, 600S, or 600D.* These NORTEC 600 series instruments measure conductivity and display the results on the screen in either %IACS or MS/m, while simultaneously measuring the coating or lift-off factor in inches or millimeters.

Conductivity probes are available in frequencies of 60 kHz or 480 kHz and are supplied with a 16-Pin LEMO connector enabling Powerlink functionalities.

How do our conductivity probes and standards work?

Our conductivity probes use a system for measuring and certifying electrical conductivity of metals that operate using the four-point DC resistance technique for primary standards. These standards are maintained by Evident at all times and are recertified at set intervals to comply with NIST traceability. The primary standards and test pieces are maintained in a 20 °C (±10 °C) environment and the test pieces are measured using the AC impedance transfer method. The entire system is computer controlled for accuracy and repeatability.

Using this technique of primary standards, our conductivity probes are capable of certifying conductivity standards to a high degree of accuracy:

*Not compatible with the base NORTEC 600 model.

Conductivity Probes

Type
Series
Frequency
Height
Length
Connector
Part number
Item number
Conductivity Probes
Right Angle
60 kHz
19.1 mm (0.75 in.)
25.4 mm (1.00 in.)
16-Pin LEMO
9222340
U8690027
Conductivity Probes
Right Angle
480 kHz
19.1 mm (0.75 in.)
25.4 mm (1.00 in.)
16-Pin LEMO
9222341
U8690028
Conductivity Probes
Straight
60 kHz
7.9 mm (0.31 in.)
69.9 mm (2.75 in.)
16-Pin LEMO
9222360
U8690029
Conductivity Probes
Straight
480 kHz
7.9 mm (0.31 in.)
69.9 mm (2.75 in.)
16-Pin LEMO
9222361
U8690030

Conductivity Standards

Part number
Item number
IACS % Value #1 (tolerance)
IACS % Value #2 (tolerance)
IACS % Value #3 (tolerance)
IACS % Value #4 (tolerance)
IACS % Value #5 (tolerance)
CREF2-04100
U8861784
4.6 (±0.4)
100.0 (±10)
n.a
n.a
n.a
CREF2-1742
U8861881
17.2 (±1.5)
42.7 (±4.4)
n.a
n.a
n.a
CREF2-2932
U8861830
29.3 (±3)
32.0 (±3.3)
n.a
n.a
n.a
CREF3-0129100
U8861910
1.5 (±0.1)
29.3 (±3)
100.0 (±10)
n.a
n.a
CREF3-172942
U8861675
17.2 (±1.5)
29.3 (±3)
42.7 (±4.4)
n.a
n.a
CREF3-172959
U8861822
17.2 (±1.5)
29.3 (±3)
59.9 (±6)
n.a
n.a
CREF3-294259
U8861924
29.3 (±3)
42.7 (±4.4)
59.9 (±6)
n.a
n.a
CREF4-17294259
U8861629
17.2 (±1.5)
29.3 (±3)
42.7 (±4.4)
59.9 (±6)
n.a
CREF4-17294259
U8861629
17.2 (±1.5)
29.3 (±3)
42.7 (±4.4)
59.9 (±6)
n.a
CREF4-173259100
U8861982
17.2 (±1.5)
32.0 (±3.3)
59.9 (±6)
100.0 (±10)
n.a
CREF5-01293242100
U8861902
1.5 (±0.1)
29.3 (±3)
32.0 (±3.3)
42.7 (±4.4)
100.0 (±10)
CREF5-04174559100
U8861929
4.6 (±0.4)
17.2 (±1.5)
45.7 (±4)
59.9 (±6)
100.0 (±10)