Miniature Angle Beam Transducers and Wedges are used primarily for testing of weld integrity. Their design allows them to be easily scanned back and forth and provides a short approach distance. Angle beam transducers are single element transducers used with a wedge to introduce a refracted shear wave or longitudinal wave into a test piece.
Advantages:
- Three-material design of our Accupath wedges improves signal-to-noise characteristics while providing excellent wear resistance
- High temperature wedges available for in-service inspection of hot materials
- Wedges can be customized to create nonstandard refracted angles
- Available in interchangeable or integral designs
- Contouring available
- Wedges and integral designs are available with standard refracted angles in aluminum
Applications:
- Flaw detection and sizing
- For time-of-flight diffraction transducers see page 25
- Inspection of pipes, tubes, forgings, castings, as well as machined and structural components for weld defects or cracks
Miniature Screw-In Transducers
- Screw-in design 303 stainless steel case
- Transducers are color coded by frequency
- Compatible with Short Approach, Accupath, High Temperature and Surface Wave Wedges
Transducer Dimensions (in inches)
| Nominal Element Size | (A) | (B) | (C) | Thread Pitch |
| 0.50 | 0.71 | 0.685 | 0.257 | 11/16 - 24 |
| 0.375 | 0.58 | 0.65 | 0.257 | 9/16 - 24 |
| 0.25 | 0.44 | 0.55 | 0.22 | 3/8 - 32 |
(MHz)
U8435024
U8431027
U8435016
U8436018
U8431036
U8431030
U8435019
U8436021
U8431037
U8435025
U8436027
U8431028
U8435017
U8436019
U8431034
U8435023
U8436025
U8431038
U8435026
U8436028
U8431033
U8435022
U8436024
U8431031
U8435020
U8436022
U8431039
U8435027
U8436029
U8431029
U8435018
U8436020
U8431032
U8435021
U8436023
U8431040
U8436030
U8431035
U8436026
Accupath & Short Approach Wedges
Accupath Wedges
- Small wedge footprint
- Pointed toe design allows transducer rotation even when the nose is touching a weld crown
- Special wedge design for use with 10 MHz transducer
Miniature Screw-In Wedges for 10 MHz Transducers
Nominal Element Size
Colspan=2
Wedge Part Numbers
Colspan=2
*Accupath Wedges are available in standard refracted shear wave angles of 30°, 45°, 60°, and 70° in steel at 10 MHz.
Short Approach Wedges
- Smallest footprint
- Short approach distance allows for inspection closest to the weld crown
0.5
Colspan=4
0.375
Colspan=4
0.25
Colspan=4
Wedge Configurator
Transducer Configurator
This wedge configurator contains only 1-5 MHz Miniature Screw-in Short Approach, Accupath, High Temp, Very High Temp, and Surface Wave wedges.
*Accupath Wedges are available in standard refracted shear wave angles of 30°, 45°, 60°, and 70° in steel at 10 MHz.
Nominal Element Size
Colspan=2
Temperature Range °F
colspan=2