Immersion Accessories

Thickness and Flaw Inspection Solutions

Contact Us

Immersion transducer accessories aid in immersion applications and techniques. Accessories include bubblers, immersion tanks, reflective mirrors and search tubes.

Reflective Mirrors

  • Directs sound beam when a straight-on inspection is not possible
  • Standard mirrors provide a 90° reflection of the sound beam
Case Style Incident Angle Part Numbers
(°)
Standard 45 F102
Slim Line 45 F132
Pencil 45 F198

Note: Contact us for other reflected angles.

Bubblers (RBS, Handheld)

  • Allows for immersion testing when complete immersion of parts is not desirable or possible
  • Designed to maintain a consistent, low volume flow of water
Part Numbers Diameter Opening Water Path Case Style Nominal Element Size Opening Type
inches mm inches mm inches mm
MPF-B-0.5 0.300 7.6 1.00 25.4 Standard SU 0.125 3 flat
0.25 6 flat
B103 0.350 8.9 0.775 19.7 Standard SU 0.125 3 V-notch
0.25 6 V-notch
B103A 0.350 8.9 0.475 12.1 Standard SU 0.125 3 flat
0.25 6 flat
B103W 0.550 14 0.775 19.7 Standard SU 0.375 10 V-notch
0.50 13 V-notch
B103AW 0.550 14 0.475 12.1 Standard SU 0.375 0.375 flat
0.50 13 flat
B116 0.100 2.5 variable, min. of: Fits SU/RM case style 0.125 3 flat
0.075 1.9 0.25 6 flat
B117 1.375 34.4 1.400 35.6 Large Diameter 1.00 25.4 V-notch

RBS-1 Immersion Tank

RBS-1 immersion tank is designed to simplify testing measurements using immersion techniques. It consists of a clear acrylic tank, a submersible pump and a transducer fixture in a single, portable unit. The pump feeds an adjustable stream of water to a bubbler mounted in the fixture, providing a water column to couple sound from an immersion transducer into the test piece. It is ideal for offline thickness measurements on metal, glass and plastic products such as small containers, pipe or tubing, sheets or plates or machined parts.

Clear Acrylic Tank

  • 5.5 x 12 x 8 inches (140 x 305 x 200 mm)
  • 0.83 gallon (3.1 liter) capacity

Pump

  • Up to 0.25 gallons (0.9 liters) per minute
  • 115 or 230 V, 30 Watt (voltage range 90 to 135 VAC), 50 to 60 Hz
  • Submersible (ground fault interrupter circuit recommended)

Handheld Bubbler Transducer Assembly

Handheld bubbler transducers are available in either 20 MHz (V316B) or 10 MHz (V312B). They are immersion transducers that screw onto a bubbler assembly (B120) which has a replaceable stainless steel tip and a water feed tube. They offer high resolution and easy access inspection of thin materials. The V316B and bubbler combination can resolve thicknesses down to 0.008" (0.2 mm).

Frequency Nominal Element Size Focal Length Transducer Part Number Bubbler Assembly Replacement Tip Flexible Tip
MHz inches mm inches mm
10 0.25 25 1.00 25 V312B-RM B120 B120-TIP B120-FLEX-TIP
20 0.125 3 0.75 19 V316B-RM B120 B120-TIP B120-FLEX-TIP

Immersion Search Tubes

  • Provides a quick and easy way to fixture and manipulate immersion transducers
Part Numbers Length Fits Connector Styles Outside Diameter
inches mm inches mm
F112 1.5 38 UHF to UHF 0.738 18.75
F113 2 51 UHF to UHF 0.738 18.75
F114 3 76 UHF to UHF 0.738 18.75
F115 6 152 UHF to UHF 0.738 18.75
F116 8 203 UHF to UHF 0.738 18.75
F117 12 305 UHF to UHF 0.738 18.75
F118 18 457 UHF to UHF 0.738 18.75
F119 24 610 UHF to UHF 0.738 18.75
F120 30 762 UHF to UHF 0.738 18.75
F211 12 305 Microdot ® to Microdot 0.312 7.92