- Select from a variety of cable grades to meet your specific application needs
- Standard lengths 3' (1 m), 4' (1.2 m), 6' (1.8 m). When ordering, replace the x in the part number with the desired cable length in feet
- Custom cable lengths are available; please specify when ordering
- Part numbering prefix indicates connector style for both ends of the cable
- All cables are 50 ohms impedance unless otherwise specified
- Contact us for special or customized cables
Standard
Cable Part Number |
Fits Connector Style |
BCB-58-x | Fits BNC to BNC |
BCB-74-x | Fits BNC to BNC |
BCM-74-x | Fits BNC & Microdot® |
BCMA-74-x | Fits BNC & Microdot without Boot |
BCRM-74-x | Fits BNC & Right Angle Microdot |
BCU-58-x | Fits BNC to UHF |
BCU-62-x | Fits BNC to UHF |
FLCB-74-x | Fits Female Lemo® & BNC |
LCB-74-x | Fits Small Lemo 00 & BNC |
LCM-74-x | Fits Small Lemo 00 & Microdot |
LCU-74-x | Fits Small Lemo 00 & UHF |
L1CB-58-x | Fits Large Lemo 1 & BNC |
L1CM-74-x | Fits Large Lemo 1 & Microdot |
L1CU-74-x | Fits Large Lemo 1 & UHF |
L1CU-74-x | Fits Large Lemo 1 & UHF |
UCM-74-x | Fits UHF & Microdot |
UCU-58-x | Fits UHF to UHF |

Heavy Duty & Waterproof
Heavy Duty Cable & Waterproof Types
- Heavy Duty
- Heavy Duty, Armored Super Flexible Silicone (HDAS)
- Heavy Duty, Armored PVC (HDAP)
- Waterproof
Heavy Duty (HD)
External Teflon ® coating provides flexibility and improved cable performance in industrial settings
Cable Part Numbers
Fits Connector Style
BCB-188-x HD
Fits BNC to BNC
BCM-188-x HD
Fits BNC & Microdot
BCU-188-x HD
Fits BNC to UHF
LCB-188-x HD
Fits Small Lemo 00 & BNC
LCM-188-x HD
Fits Small Lemo 00 & Microdot
Heavy Duty, Armored PVC (HDAP)
Spiral stainless steel jacket with external solid PVC coating makes this cable very durable
Cable
Part Numbers
Part Numbers
Fits Connector Style
BCB-188-x HDAP
Fits BNC to BNC
BCM-188-x HDAP
Fits BNC to Microdot
BCU-188-x HDAP
Fits BNC to UHF
LCB-188-x HDAP
Fits Small Lemo 00 to BNC
LCM-188-x HDAP
Fits Small Lemo 00 to Microdot
Heavy Duty, Armored Super Flexible Silicone (HDAS)
Stainless steel jacket with an external silicone coating makes this cable durable, yet flexible
Cable
Part Numbers
Part Numbers
Fits Connector Style
BCB-188-x HDAS
Fits BNC to BNC
BCM-188-x HDAS
Fits BNC to Microdot
BCU-188-x HDAS
Fits BNC to UHF
LCB-188-x HDAS
Fits Small Lemo 00 to BNC
LCM-188-x HDAS
Fits Small Lemo 00 to Microdot
Waterproof (W)
Specially designed proprietary waterproof UHF connector provides a waterproof connection good to depths of about 150 feet (50 m) in fresh water
Cable Part Numbers
Fits Connector Style
BCM-74-x W
Fits BNC to Waterproof Microdot
BCRM-74-x W
Fits BNC to Waterproof Right Angle Microdot
BCU-58-x W
Fits BNC to Waterproof UHF
BCU-62-x W
Fits BNC to Waterproof UHF
BCU-74-x W
Fits BNC to Waterproof UHF
LCM-74-x W
Fits Small Lemo 00 to Waterproof Microdot
LCU-74-x W
Fits Small Lemo 00 to Waterproof UHF
L1CU-74-x W
Fits Large Lemo 1 to Waterproof UHF
Cables with Handle
- Special 3" (75 mm) long reinforced handle for increased durability and easier grip
- Custom handles can be ordered 6" (152 mm), 9" (229 mm)
Cable Part Numbers
Fits Connector Style
Handle Length
inches
inches
BCMH-74-X
Fits BNC & Microdot
3
LCMH-74-X
Fits Small Lemo 00 & Microdot
3
L1CMH-74-X
Fits Large Lemo 1 & Microdot
3
BCMH6-74-X
Fits BNC & Microdot
6
LCMH6-74-X
Fits Small Lemo 00 & Microdot
6
L1CMH6-74-X
Fits Large Lemo 1 & Microdot
6
BCMH9-74-X
Fits BNC & Microdot
9
LCMH9-74-X
Fits Small Lemo 00 & Microdot
9
L1CMH9-74-X
Fits Large Lemo 1 & Microdot
9
Dual, Double Shielded & SSA
Dual, Armored Stainless Steel (SSA), & Double Shielded (DS) Cable Types
- Dual
- Doubled Shielded (DS)
- Armored Stainless Steel (SSA)
Dual
Single cable design with two connectors at each end to fit dual element transducers
Cable
Part Numbers
Part Numbers
Fits Connector Style
Compatible
With
With
BCMD-74-6
Dual BNC to Microdot
Standard
LCMD-74-6
Dual Small Lemo 00 to Microdot
Dual
L1CMD-74-6
Dual Large Lemo 1 to Microdot
Transducer
BCMD-316-5F
Dual BNC to Microdot
Flush Case Dual
L1CMD-316-5F
Dual Large Lemo 1 to Microdot
Transducer
BCLPD-78-5
Dual BNC to Lepra/Con
MTD-705
L1CLPD-78-5
Dual Large Lemo 1 to Lepra/Con
Transducer
Armored Stainless Steel (SSA)
- Interlocking stainless steel jacket provides flexibility, protection and ruggedness in heavy industrial settings
- Can be ordered in lengths up to 20' (6.1m)
Cable Part Numbers
Fits Connector Style
BCB-188-x SSA
Fits BNC to BNC
BCM-188-x SSA
Fits BNC and Microdot
BCRM-188-x SSA
Fits BNC and Right Angle Microdot
BCU-188-x SSA
Fits BNC to UHF
LCM-188-x SSA
Fits Small Lemo 00 & Microdot
LCRM-188-x SSA
Fits Small Lemo 00 & Right Angle Microdot
Double Shielded (DS)
- Additional grounded shield provides low cable noise for better performance in high frequency applications
- 15 ohm or 25 ohm cable of different lengths may help to optimize high frequency system performance
Cable
Part Numbers
Part Numbers
Fits Connector Style
Impedance
BCM-74-x DS
Fits BNC & Microdot
50 ohms
BCM-15-x DS
Fits BNC & Microdot
15 ohms
BCM-25-x DS
Fits BNC & Microdot
25 ohms