Magnetic Flux Leakage Probes

Thickness and Flaw Inspection Solutions

Contact Us

TFB - Attached

The magnetic flux leakage probes offer a superior high-saturation optimized magnetic design. Changeable wear rings improve wear resistance. These probes are ideal for air-cooler tubing inspection (with aluminum fins) and for circumferential crack detection.

Features

  • Superior high-saturation optimized magnetic design.
  • Improved wear resistance and changeable wear rings.
  • Can detect outside volumetric defects.
  • Suitable for air-finned coolers.

Faster is better - Available for shortest delivery times

The probes listed below are regularly stocked for quick delivery. If the probe you require is not indicated, consult the "Alternate probe diameter" column in the Tube Inspection Probe Catalog to find an alternate probe diameter.

Part ID

Rowspan=2

Item Number

Rowspan=2

Diameter
mm
in.
TFB-120-N20
U8280231
12
0.472
TFB-132-N20
U8280135
13.2
0.520
TFB-170-N20
U8280137
17
0.669
TFB-179-N20
U8280111
17.9
0.705
TFB-187-N20
U8280246
18.7
0.736
TFB-198-N20
U8280361
19.8
0.780
TFB-242-N20
U8280099
24.2
0.953

Standard/Custom Probes (Made to Order)

Use the nomenclature and the chart below to configure your part number.

Chart TFB

Probe Type

Rowspan=2

Probe Diameter (use mm in part ID)

Colspan=3

Cable Length

Rowspan=2

Part Number Diameter
mm**
in.**

TFB: Magnetic flux leakage probe

Rowspan=11

120*
12.0
0.472

20 m (65 ft)
30 m (100 ft)

Rowspan=11

132*
13.2
0.520
161*
16.1
0.634
170*
17.0
0.669
179
17.9
0.705
187
18.7
0.736
198
19.8
0.780
229
22.9
0.902
242
24.2
0.953
283
28.3
1.114
296
29.6
1.165

* Smaller-diameter probes have less sentitivity to external defects, because the probe core section is much smaller than the tube section. However, the sensitivity to internal defects is still very high.

** These probes have an overall diameter that is slightly larger than the part number reference.

MFL Probe Selection Based on Tube Size

High-Saturation MFL Probe (TFB Model) Selection Guide for Common Carbon Steel Tube Sizes

Warning: If your tubes are dirty, a smaller probe might be required for the inspection. Evident is not responsible if you select a probe that is not compatible with your application. If you require assistance, please contact an Evident representative.

Example: For a one-inch tube with a wall thickness of 2.41 mm, the required probe would be TFB-187-N20. This probe has an overall diameter of 19.4 mm and changeable hardened steel half-rings.

Colspan=3

Probe ID Diameter - mm (in.)

Colspan=11

Tube Dimensions

Colspan=3

12.0 (0.472)
13.2 (0.520)
16.1 (0.634)
17.0 (0.669)
17.9 (0.705)
18.7 (0.736)
19.8 (0.780)
22.9 (0.902)
24.2 (0.953)
28.3 (1.114)
29.6 (1.165)

OD
mm (in.)

Rowspan=2

BWG

Rowspan=2

WT
mm (in.)

Rowspan=2

Overall Diameter (including wear system) - mm (in.)

Colspan=11

12.5
to 12.8 (0.49 to 0.50)
13.7
to 14.0 (0.54 to 0.55)
16.6
to 16.9 (0.65 to 0.66)
18
(0.71)
18.7
(0.73)
19.4
(0.77)
20.5
(0.81)
23.8
(0.94)
25.1
(0.99)
29.2
(1.15)
30.5
(1.20)

19 (0.75)

Rowspan=4

16
1.65 (0.065)
●
14
2.11 (0.083)
●
13
2.41 (0.095)
●
Δ
12
2.77 (0.109)
●

25.4 (1.0)

Rowspan=8

16
1.65 (0.065)
●
15
1.83 (0.072)
●
14
2.11 (0.083)
●
13
2.41 (0.095)
Δ
●
12
2.77 (0.109)
●
11
3.05 (0.12)
●
10
3.40 (0.134)
Δ
●
9
3.76 (0.148)
●

31.75 (1.25)

Rowspan=4

13
2.41 (0.095)
●
12
2.77 (0.109)
●
11
3.05 (0.12)
●
10
3.40 (0.134)
●

38.1 (1.5)

Rowspan=4

12
2.77 (0.109)
●
11
3.05 (0.12)
●
10
3.40 (0.134)
●
9
3.76 (0.148)
●

Wear System

colspan=3

Carbide beads (fixed)

colspan=3

Hardened steel half-rings (changeable)

colspan=8

● This is the recommended probe size.

Δ This size can be used if you do not have the recommended size.