Arvios Operating Software

Arvios is the industry’s first videoscope operating software built specifically for remote visual inspection (RVI). A unified platform powering IPLEX™ One and future IPLEX devices, Arvios brings a consistent experience to every inspection and keeps getting better over time. This is what’s next in remote visual inspection.

Operating Software That Puts the Inspector First

RVI has always demanded more from the people who perform it than from the tools they use. Reproducing conditions from one inspection to the next, tracking defects across dozens of images, and rebuilding context once files leave the device have all taken time away from the inspection itself. Arvios changes that.

https://adobeassets.wabtecint.com/content/dam/tnm/arvios/media/Arvios_16x9_Final_1.mp4

Built for How You Actually Work

Arvios is designed around how RVI actually works—and how much easier it can actually be. The Arvios interface is as simple and intuitive as the smartphone in your pocket, purpose-built for the complexity of real inspection tasks.

  • Friendly Navigation: Created with modern web technology, the Arvios interface uses familiar navigation—icons, color-coded status indicators—adapted for the demands of industrial RVI.
  • Clean, Focused Live View: A virtual joystick and a collapsible drawer menu clear the way for a full-screen live feed. Customize your view and keep your most-used tools one tap away with toolbar shortcuts.
  • Smart Measure: Simply tap a defect and measurement points automatically appear around its boundary along with calculated measurements.
  • Full 3D Measurement Model: 3D Stereo Stitching turns measurable video into a fully rotatable 3D measurement model. Take your target area far beyond what a single field of view can achieve with Full 3D View.
  • Freeze, Tag, and Tell the Full Story: Freeze a frame, annotate it, tag it, and add comments before saving. Adjust frozen image settings and take measurements, and create annotation overlays to mark key details.
  • Spot the Defect: The Focal Tool’s movable zoom window lets you zero in on your inspection target with precision and control.
  • Efficient File Management: Tree structure navigation, file type indicators, and folder-level snapshots make it easy to manage data directly on your device. Your working directory is visible at all times, so you always know exactly where your data is.

Built for Every Device in Your Fleet

Arvios delivers a single, unified inspection experience across your entire operation. Every file carries the full inspection story—on the device, in ViSOL™, and on your PC.

  • Cross-Device Consistency: The same navigation, menu structure, and workflow logic run across every Arvios-powered device. An inspector trained once stays productive as your fleet grows.
  • Settings That Follow the Inspector: Custom scenes save your image settings so you can reuse the same settings the next time you pick up the device. Add, edit, or delete scenes at any time.
  • Inspection Data Continuity: Arvios captures and preserves rich metadata—image settings, tags, annotations, inspection conditions, and measurements—so the full context
of every inspection travels with the data.
  • Seamless Connectivity: Arvios connects directly and securely to ViSOL, Evident Connect, and other approved cloud and desktop apps. When connected, field data syncs automatically and arrives where it needs to be, complete and ready to act on.
  • Online and Offline Security: Security controls and personalization can function without an internet connection, making Arvios fully suited for defense, aerospace, and other restricted-access applications.

Built to Evolve with What Comes Next

Arvios is engineered to advance, keeping your entire fleet current as new updates are released. Agile development allows new capabilities to arrive faster, and security is built in from the ground up so every update is protected.

  • New Updates Every Quarter: New features and improvements arrive over the air for connected devices, or USB for offline sites. Staying current is never a barrier.
  • Secure and Easy Upgrading: Updates and upgrades automatically deploy wirelessly. For offline or restricted environments, a QR code unlocks new features without an internet connection. USB is also available as a fallback.
  • Designed for Every Generation: Beginning with IPLEX One, every device added to your fleet will share the same software foundation. As your fleet grows and technology advances, Arvios ensures that your entire operation moves forward as one.
  • Open Evolution: With an open architecture and a modular software foundation, new features arrive on a predictable cadence so you’re never waiting years for the next hardware generation.

Features

Designed Around the Inspector

Arvios puts advanced RVI capabilities within easy reach. From saved image settings to one-tap area measurement and full 3D models, each Arvios feature was developed to shorten the path from what you image to what you can report. (Feature availability depends on your IPLEX One device grade.)

Request Demo

Custom Scenes

Custom scenes save your image settings, so the right setup is ready the next time you pick up the device. Create a new scene, adjust your image settings, and save your new settings as a scene. Work the way you want, regardless of when or where.

Focal Tool

Focal Tool opens a movable zoom window with live Z distance for highly specific cursor placement. Lock the crosshair and make fine movements within the zoom window without losing your place, ensuring that even the smallest indications get the scrutiny they deserve.

Auto Area

Auto Area automatically detects and places measurement points within a selected region and instantly calculates the affected area. Results can be fine-tuned by adjusting the points for faster and more consistent evaluation of thermal barrier coating (TBC) loss, corrosion, erosion, and gear damage.

3D Stitching

As the scope moves across the target, 3D Stitching combines multiple scans into one complete three-dimensional view so you can analyze the full geometry of parts such as turbine blades. More measurement confidence, better defect documentation, more accurate reports.

Inspection Data Continuity

Arvios turns every inspection image into a complete record. Annotations, tags, comments, and inspection metadata stay attached to the image both on the device and wherever it is shared. Every file leaves the device with complete context and nothing is lost between inspection, review, and reporting.

Applications

Wherever RVI Takes You

Inspection looks different inside a jet engine than it does in a gearbox or refinery pipe. Arvios brings the right tools to the specific challenges of every RVI application, from tracking blade IDs to working without a network connection.

Request Demo

Aviation

Blades don’t always fit in a single image, and defects may sit across multiple frames. Arvios enables faster blade inspections with fewer counting and location errors:

  • Full 3D Measurement Model: Create a complete 3D model of a blade to accurately locate defects beyond a single field of view
  • Smart Measure: Tap a defect, and Arvios places the measurement points and recommends the ideal measurement method
  • Blade Counter: Count and track blades automatically to keep blade IDs and defect locations accurate

Wind Power

Gearbox inspections contend with difficult lighting, inconsistent imaging, and findings that need to reach off-site teams. Arvios delivers repeatable inspections and quicker handoffs to remote engineers:

  • Scenes and Metadata: Save and reproduce optimal imaging conditions for consistent inspections
  • Rich Annotations: Clearly mark and document gearbox defects with visual context
  • Post-Inspection Cloud Sync: Sync inspection data with ViSOL or your own approved cloud applications

Oil and Gas / Chemical

Corrosion and weld defects are hard to capture consistently, document in detail, and measure in the field. Take measurements on the spot and ensure precise records with Arvios:

  • Scenes and Metadata: Improve corrosion visibility and repeat the same conditions from one inspection to the next
  • Tell the Full Story: Document weld and corrosion findings with clear visual references
  • On-Device Pipe Measurement: Measure weld and corrosion indications on the device using cylindrical pipe modeling

Power Generation

Turbine inspections can span hundreds of folders and must stay aligned from planning through reporting. Arvios means less time spent on file administration and a clean line from plan to report:

  • Efficient File Management: Quickly navigate large turbine inspection structures with filtering and sorting tools
  • Seamless Connectivity with ViSOL: Keep inspection plans, findings, and reports aligned throughout the inspection workflow
  • Inspection Data Continuity:Capture detailed findings and transfer inspection context into reporting workflows

Aerospace and Defense

Mission-critical defects can be hairline-thin, and security requirements often rule out a network connection. Arvios enables confident calls, with no compromise in security:

  • Advanced Security Controls: Configure air-gapped operation, storage restrictions, and controlled data access
  • Precision Zoom: Examine hairline cracks and defects with enhanced inspection visibility
  • Rich Annotations and Tags: Maintain detailed documentation and traceability for mission-critical inspections

Experience Arvios for Yourself

Contact us today to schedule a free demo showcasing Arvios operating software on the IPLEX One videoscope.

Schedule Your Demo

Resources