RTIS: Rotating Tube Inspection System

The rotating tube inspection system (RTIS) is a turnkey solution that uses phased array probes integrated into a fully automated testing system to meet stringent requirements for volume and surface inspections. Key benefits include:

The rotating tube inspection system (RTIS) is a turnkey solution that uses phased array probes integrated into a fully automated testing system to meet stringent requirements for volume and surface inspections. Key benefits include:

  • Minimize your dependency on operator skill with automatic calibration
  • Detect defects at production speed with calibration check
  • Familiar to major oil companies
  • Detects oblique defects to meet current and pending industry standards
  • Get the most out of the system with 2D mapping and end-of-tube inspection capabilities

Designed to be an easy-to-use solution for helping ensure the quality of seamless and electric resistance welded tubes, the system includes:

  • Dedicated project management
  • Instruments, probes, and mechanical equipment
  • Water management system
  • Software
  • Commissioning, training, and after-sales support

https://adobeassets.wabtecint.com/content/dam/tnm/videos/RTISFSW_V1-4.mp4

Full Body Tube Inspection

Inspect for longitudinal, transverse, oblique, and lamination defects, and measure wall thickness.

Longitudinal

Transverse

Oblique

Maximize Your Productivity

The system is adaptable and can be configured to suit different types of inspections.

Automatic Calibration

To achieve a thorough inspection, each phased array probe must be calibrated. During calibration, the apertures of each probe pass over a known defect, and the probe’s gain level is automatically adjusted. This feature enables users to easily perform and validate a precise calibration of each focal law, saving time without relying on the user’s skill.

  • All probes can be calibrated in a single automatic sequence
  • Calibration check performed under normal production conditions
  • Each reference defect is validated to help ensure they’re detected above the alarm level
  • Results are displayed in an easy-to-interpret strip chart and weld mapping view

Software and Acquisition Unit

The combination of phased array probes, a powerful acquisition unit, and advanced software work together to deliver a powerful, easy-to-use inspection system.

Phased Array Acquisition Unit

The QuickScan™ PA 32:256 module meets IP55 standards and is designed to easily integrate into industrial environments.

Easy Setup

QuickView software makes it easy to setup the system and acquire and manage data.

The software’s wizard makes it simple to create setups for each part size. The inspection configuration and calibration parameters for each pipe diameter are saved and easily retrievable. The final results are merged and displayed to clearly differentiate between accepted and rejected tubes.

  • Quickly access predefined inspection setups
  • Software wizard makes it simple to create new setups
  • Restrict access to certain users to help minimize operator errors
  • Calibration and inspection info are stored for traceability
  • Acquisition files are created for every inspected tube, and these data can be stored locally or remotely
  • Custom reporting and advanced process control tools

Clear Results

When the inspection is complete, the results are merged and displayed to clearly differentiate between accepted and rejected tubes.

  • Easy-to-interpret inspection results with real-time strip chart displays
  • Quickly reconfigure when changing pipe sizes
  • Detailed alarms and data reporting
  • Supervisor software that merges and archives data in one common database and centralizes results and displays on a single work station
  • Easily interfaces with two production line systems

Specifications

Standard Product Range
Diameter
60 mm to 508 mm (2 3/8 in. to 20 in.)
Wall Thickness
4 mm to 75 mm (0.157 in. to 2.95 in.)
WT/OD
< 0.3
Length
6 m to 15 m (20 ft. to 50 ft.)
Speed
60.3 mm (2 3/8 in.) : 1 m/s (200 ft./min)
244.4 mm (9 5/8 in.) : 0.25 m/s (50 ft./min)
406.4 mm (16 in.) : 0.15 m/s (30 ft./min)
Inspection Coverage
Axial Pulse Density (APD)
Configurable (0 to > 50% overlap)
Radial Pulse Density (RPD)
Configurable (1.0 mm to 2.0 mm)
Data Presentation
Real-Time Inspection Results
C-scan, strip charts, and alarms
Parameter Setup
A-scan, B-scan
Inspection Layout
20 different user-configurable layouts
Inspection Modes
Typical Inspection Modes
Longitudinal, transverse, oblique, lamination, and wall thickness measurement
Firing Modes
Pulse-echo
Inspection Mode Configuration
Several inspection modes can be performed simultaneously on the same PA probe.
Detection Capabilities for Typical Reference Defects
API References
12.7 mm/25.4 mm N10 and N5, ID and OD longitudinal, traverse, and oblique notches;
3.2 mm and 1.6 mm through-drilled hole (TDH), 6.35 mm flat bottom hole (FBH)
Signal-to-Noise Ratio (SNR)
> 12 dB
Repeatability
L notches: < 2 dB
T and Ob notches: < 3 dB
TDH 3.2 mm and FBH 6.35 mm: < 4 dB
Reporting and Data Storage
Report types
Inspection, calibration, and calibration-check user-configurable reports
Storage
Real-time database inspection data storage