Vanta Max XRF Analyzer
The Vanta Max model offers the series’ highest analytical capabilities for robust applications, including mineral exploration, academic research, soil testing, and environmental analysis. For rare earth element detection, the Vanta Max 55 kV tungsten tube model provides geologists and exploration teams with the enhanced sensitivity they need.
The Power to Unearth More
Fast, Reliable Geochemical Analysis — Right at the Drill Site
The Vanta Max XRF Analyzer is our most powerful solution for real-time geochemical analysis in exploration, mining, and grade control. Designed for rugged field conditions and engineered for analytical precision, the Vanta Max analyzer empowers geologists and exploration teams to make confident decisions—instantly.
For the detection of rare earth elements and heavy elements, opt for the power of our Vanta Max 55kV tungsten anode tube model. Its enhanced sensitivity enables you to detect these elements and low-level indicators:
Rare Earth Elements Lanthanum (La), cerium (Ce), praseodymium (Pr), neodymium (Nd), samarium (Sm), europium (Eu), gadolinium (GD)
Heavy Elements Trace silver (Ag), cadmium (Cd), tin (Sn), antimony (Sb), barium (Ba)
Built to Last, Proven to Perform
Exploration doesn’t always happen in ideal conditions. That’s why the Vanta Max analyzer is engineered to perform in the world’s toughest environments.
- IP64-rated for dust and water resistance
- Drop-tested to MIL-STD-810G
- Operates in extreme temperatures, from desert heat to alpine cold
Boost Productivity. Reduce Costs. Make Smarter Decisions.
- On-site decision making: With the Vanta Max XRF in your toolkit, your team gains lab-quality results in the field, saving time, reducing sample backlogs, and increasing confidence in every decision.
- Peace of mind: Built on a legacy of rugged XRF analyzers trusted across mining operations, the Vanta Max analyzer is backed by a comprehensive three-year warranty.
- Trusted XRF technology: Vanta series’ proprietary Axon Technology uses ultra-low-noise electronics, enabling a higher X-ray count rate for fast, accurate, and repeatable results.
Applications
Core Applications in Mining
Exploration Drilling
- Screen and prioritize samples for lab analysis
- Identify mineralized zones early in the campaign
Grade Control
- Define ore/waste boundaries with precision
- Optimize blasting and excavation strategies
Environmental Monitoring
- Analyze tailings, soils, and water for heavy metal contamination
Field Mapping
- Generate real-time lithogeochemical maps to guide future drilling
Geochemistry-Optimized Configurations
- Optional geochemical calibration packages available
- Soil Foot and sample cups for consistent, repeatable analysis
(See Accessories for more information about the Soil Foot.)
Standard Mining Kit Includes:
- Vanta Max™ Analyzer with Mining+ Geochem calibration
- Rugged IP64 case
- Field calibration check standard
- 2x batteries and charger
Vanta for Environmental Assessments
Vanta handheld XRF analyzers for soils and sediment analysis provide fast, accurate environmental remediation and assessment data. Simple to use, Vanta analyzers are rugged for the most demanding field applications.
Vanta for Regulatory and Safety Screening
Vanta handheld XRF analyzers are used to ensure compliance with RoHS and local or international regulatory laws. Vanta analyzers provide on-the-spot chemical analysis of consumer products to quickly scan for Pb, Cd, Hg, Cr, and Br.
Software
Software Features That Deliver Fast ROI
In addition to providing elemental measurements in seconds, Vanta Max handheld XRF analyzers’ innovative features maximize the efficiency and efficacy of your data analysis and reporting workflow.
Seamless Workflow and Data Management
- Empirical Mode for advanced analysis
- Embedded GPS: Enables GPS tagging of every analysis for easy mapping
- Wireless connectivity: Bluetooth®, Wi-Fi®, and USB for instant data transfer to the Evident Connect cloud or other devices
- Visual geospatial trends: Compatible with geographic information system (GIS) and 3D-mine modeling software, the Vanta Max analyzer supports identifying mineralization zones more effectively.
- Streamlined reporting: Combine GPS data, XRF test results, and images from the optional 13-megapixel panoramic camera for inclusive archiving and streamlined reporting
The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Evident Corporation is under license.
Customizable for Efficient Fleet Management
Vanta analyzers are designed to enable efficient fleet management in conjunction with Vanta Desktop PC software.
- Customizable UI: Set up the interface the way you want to maximize throughput and efficiency.
- Favorites: Choose what tests or features appear on the analyzer’s home screen.
- Username and password: Managers can create unique usernames and passwords for each user.
- Push custom setups: Easily transfer custom setups and specifications to your entire analyzer fleet.
- Simple data export: Data are quickly and easily exported via a USB flash drive, Wi‑Fi®, or Bluetooth®.
Customizable for Efficient Fleet Management
Vanta analyzers are designed to enable efficient fleet management in conjunction with Vanta Desktop PC software.
- Customizable UI: Set up the interface the way you want to maximize throughput and efficiency.
- Favorites: Choose what tests or features appear on the analyzer’s home screen.
- Username and password: Managers can create unique usernames and passwords for each user.
- Push custom setups: Easily transfer custom setups and specifications to your entire analyzer fleet.
- Simple data export: Data are quickly and easily exported via a USB flash drive, Wi‑Fi®, or Bluetooth®.
Specifications
|
Accessories
Evident offers a suite of optional accessories that help you maximize the efficiency of your Vanta Max analyzer.
Vanta Work Station
The portable Vanta Work Station is battery operated for testing on the go. A fully interlocked lid and 360-degree shielding make it convenient for bagged, prepped, and liquid samples or small objects, including jewelry and circuit boards. In this closed-beam setup, users operate the analyzer using Vanta PC software or the Vanta mobile app.
The portable Vanta Work Station is effective for a variety of applications:
- Geo exploration
- Mining process control
- RoHS/consumer products
- Environmental analysis
The Work Station’s stable platform enables longer test times. It gives you the freedom to start a test in the Work Station and complete other tasks while the Vanta instrument performs the analysis. You can be confident that the sample is stable and its position is reproducible, helping ensure high-quality data and efficient sample throughput.
Easy to Use
- Simply click the Vanta analyzer into place, and release it with the press of a button
- Balanced lid system to prevent slamming
- Easy sample placement—no front wall or lip obstruction
- Control the Vanta analyzer and transfer data wirelessly or via a USB cable
Portable
- Battery or AC powered for benchtop or field use
- Easy to transport and set up
- Chamber and legs separate for easy storage
- Optional carrying case
Designed for Safety
- Fully shielded and interlocked chamber: 107 mm × 178 mm × 179 mm (4.2 in. × 7 in. × 7 in.)
- Radiation warning LEDs are large, clear, and prominent
Small Footprint
- 346 mm X 326 mm (14.4 in. × 13 in.)
Vanta Soil Foot
The Vanta Soil Foot provides a stable three-point support for the Vanta analyzer. This accessory facilitates hands-free analysis, making it convenient when longer test times are required.
Vanta Field Stand
When testing small items, such as samples in cups or bags, the Vanta Field Stand offers a lightweight, mobile test stand and shielded sample chamber. The Field Stand is easy to pack and convenient to use when you are away from your office.
Vanta Holster
Keep your Vanta analyzer safe and secure and within easy reach with the Vanta Holster. The Holster has a strap with a fastener to secure the instrument, MOLLE/PALS webbing for additional attachment options, and brass shielding.
Vanta Carry Case
Rugged, hard-shell case to securely transport your Vanta handheld XRF analyzer.