Vanta Max XRF Analyzer

The Vanta Max model offers the series’ highest analytical capabilities for robust applications, including mineral exploration, academic research, soil testing, and environmental analysis. For rare earth element detection, the Vanta Max 55 kV tungsten tube model provides geologists and exploration teams with the enhanced sensitivity they need.

The Power to Unearth More

Fast, Reliable Geochemical Analysis — Right at the Drill Site

Request Quote

The Vanta Max XRF Analyzer is our most powerful solution for real-time geochemical analysis in exploration, mining, and grade control. Designed for rugged field conditions and engineered for analytical precision, the Vanta Max analyzer empowers geologists and exploration teams to make confident decisions—instantly.

For the detection of rare earth elements and heavy elements, opt for the power of our Vanta Max 55kV tungsten anode tube model. Its enhanced sensitivity enables you to detect these elements and low-level indicators:

Rare Earth Elements Lanthanum (La), cerium (Ce), praseodymium (Pr), neodymium (Nd), samarium (Sm), europium (Eu), gadolinium (GD)

Heavy Elements Trace silver (Ag), cadmium (Cd), tin (Sn), antimony (Sb), barium (Ba)

Built to Last, Proven to Perform

Exploration doesn’t always happen in ideal conditions. That’s why the Vanta Max analyzer is engineered to perform in the world’s toughest environments.

  • IP64-rated for dust and water resistance
  • Drop-tested to MIL-STD-810G
  • Operates in extreme temperatures, from desert heat to alpine cold

Boost Productivity. Reduce Costs. Make Smarter Decisions.

  • On-site decision making: With the Vanta Max XRF in your toolkit, your team gains lab-quality results in the field, saving time, reducing sample backlogs, and increasing confidence in every decision.
  • Peace of mind: Built on a legacy of rugged XRF analyzers trusted across mining operations, the Vanta Max analyzer is backed by a comprehensive three-year warranty.
  • Trusted XRF technology: Vanta series’ proprietary Axon Technology uses ultra-low-noise electronics, enabling a higher X-ray count rate for fast, accurate, and repeatable results.

Applications

Core Applications in Mining

Exploration Drilling

  • Screen and prioritize samples for lab analysis
  • Identify mineralized zones early in the campaign

Grade Control

  • Define ore/waste boundaries with precision
  • Optimize blasting and excavation strategies

Environmental Monitoring

  • Analyze tailings, soils, and water for heavy metal contamination

Field Mapping

  • Generate real-time lithogeochemical maps to guide future drilling

Geochemistry-Optimized Configurations

  • Optional geochemical calibration packages available
  • Soil Foot and sample cups for consistent, repeatable analysis
    (See Accessories for more information about the Soil Foot.)

Standard Mining Kit Includes:

  • Vanta Max™ Analyzer with Mining+ Geochem calibration
  • Rugged IP64 case
  • Field calibration check standard
  • 2x batteries and charger

Picture 1648129961, Picture

Vanta for Environmental Assessments

Vanta handheld XRF analyzers for soils and sediment analysis provide fast, accurate environmental remediation and assessment data. Simple to use, Vanta analyzers are rugged for the most demanding field applications.

View Product

Picture

Vanta for Regulatory and Safety Screening

Vanta handheld XRF analyzers are used to ensure compliance with RoHS and local or international regulatory laws. Vanta analyzers provide on-the-spot chemical analysis of consumer products to quickly scan for Pb, Cd, Hg, Cr, and Br.

View Product

Software

Software Features That Deliver Fast ROI

In addition to providing elemental measurements in seconds, Vanta Max handheld XRF analyzers’ innovative features maximize the efficiency and efficacy of your data analysis and reporting workflow.

Seamless Workflow and Data Management

  • Empirical Mode for advanced analysis
  • Embedded GPS: Enables GPS tagging of every analysis for easy mapping
  • Wireless connectivity: Bluetooth®, Wi-Fi®, and USB for instant data transfer to the Evident Connect cloud or other devices
  • Visual geospatial trends: Compatible with geographic information system (GIS) and 3D-mine modeling software, the Vanta Max analyzer supports identifying mineralization zones more effectively.
  • Streamlined reporting: Combine GPS data, XRF test results, and images from the optional 13-megapixel panoramic camera for inclusive archiving and streamlined reporting

The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Evident Corporation is under license.

Customizable for Efficient Fleet Management

Vanta analyzers are designed to enable efficient fleet management in conjunction with Vanta Desktop PC software.

  • Customizable UI: Set up the interface the way you want to maximize throughput and efficiency.
  • Favorites: Choose what tests or features appear on the analyzer’s home screen.
  • Username and password: Managers can create unique usernames and passwords for each user.
  • Push custom setups: Easily transfer custom setups and specifications to your entire analyzer fleet.
  • Simple data export: Data are quickly and easily exported via a USB flash drive, Wi‑Fi®, or Bluetooth®.

Customizable for Efficient Fleet Management

Vanta analyzers are designed to enable efficient fleet management in conjunction with Vanta Desktop PC software.

  • Customizable UI: Set up the interface the way you want to maximize throughput and efficiency.
  • Favorites: Choose what tests or features appear on the analyzer’s home screen.
  • Username and password: Managers can create unique usernames and passwords for each user.
  • Push custom setups: Easily transfer custom setups and specifications to your entire analyzer fleet.
  • Simple data export: Data are quickly and easily exported via a USB flash drive, Wi‑Fi®, or Bluetooth®.

Specifications

Dimensions (W x H x D) 10.4 × 29.6 × 24.1 cm (4.1 × 11.6 × 9.5 in.)
Weight 1.9 kg (4.17 lb) with battery, 1.67 kg (3.67 lb) without battery
Excitation Source

X-ray tube with an application-optimized anode material.

Vanta Max option 1: 4 W with 8–50 kV rhodium anode

Vanta Max option 2: 55 kV with tungsten anode

Primary Beam Filtration 8-position autoselected filter per beam per mode; optional collimation to 3 mm diameter beam spot
Detector Silicon drift detector with a high-sensitivity graphene window
Power Removable 14.4 V Li-ion battery with hot-swap capability or 18 V power transformer 100–240 VAC, 50–60 Hz, 70 W max
Display 800 × 480 (WVGA) LCD with capacitive touch screen supporting gesture control
Operating Environment Temperature range: -10 °C to 50 °C (14 °F to 122 °F), and continuous full duty cycle with optional fan
Humidity: 10% to 90% relative humidity non-condensing
Drop Test Military Standard 810-G 4-foot (1.2 m) drop test
IP Rating and Detector Shutter

IP54* dust protected and protected against water splashing from all directions

Solid detector shutter to help prevent detector damage
*In-use position

Pressure Correction Built-in barometer for automatic altitude and air density correction
GPS Embedded GPS / GLONASS receiver
Operating System

Linux

Cloud enabled with user fleet manager capability

Data Storage microSD slot with removable 1 GB industrial SD card included
USB (2) USB 2.0 Type-A ports for accessories such as Wi-Fi, Bluetooth, and USB flash drives
(1) USB 2.0 Type Mini-B port for connection to computer
Wi-Fi® Supports an 802.11 b/g/n (2.4 GHz) cable optional USB adapter
Bluetooth® Supports Bluetooth with an optional USB adapter
Aiming Camera Optional full VGA CMOS camera
Panorama Camera 13-megapixel CMOS camera with autofocus lens (optional)
Warranty Three-year warranty
Selected Optional Accessories Field Stand, Soil Foot, Holster, Work Station, Weld Mask, Hot Heel, and Probe Shield

Accessories

Evident offers a suite of optional accessories that help you maximize the efficiency of your Vanta Max analyzer.

Vanta Work Station

The portable Vanta Work Station is battery operated for testing on the go. A fully interlocked lid and 360-degree shielding make it convenient for bagged, prepped, and liquid samples or small objects, including jewelry and circuit boards. In this closed-beam setup, users operate the analyzer using Vanta PC software or the Vanta mobile app.

The portable Vanta Work Station is effective for a variety of applications:

  • Geo exploration
  • Mining process control
  • RoHS/consumer products
  • Environmental analysis

The Work Station’s stable platform enables longer test times. It gives you the freedom to start a test in the Work Station and complete other tasks while the Vanta instrument performs the analysis. You can be confident that the sample is stable and its position is reproducible, helping ensure high-quality data and efficient sample throughput.

Easy to Use

  • Simply click the Vanta analyzer into place, and release it with the press of a button
  • Balanced lid system to prevent slamming
  • Easy sample placement—no front wall or lip obstruction
  • Control the Vanta analyzer and transfer data wirelessly or via a USB cable

Portable

  • Battery or AC powered for benchtop or field use
  • Easy to transport and set up
  • Chamber and legs separate for easy storage
  • Optional carrying case

Designed for Safety

  • Fully shielded and interlocked chamber: 107 mm × 178 mm × 179 mm (4.2 in. × 7 in. × 7 in.)
  • Radiation warning LEDs are large, clear, and prominent

Small Footprint

  • 346 mm X 326 mm (14.4 in. × 13 in.)
Picture

Vanta Soil Foot

The Vanta Soil Foot provides a stable three-point support for the Vanta analyzer. This accessory facilitates hands-free analysis, making it convenient when longer test times are required.

Picture

Vanta Field Stand

When testing small items, such as samples in cups or bags, the Vanta Field Stand offers a lightweight, mobile test stand and shielded sample chamber. The Field Stand is easy to pack and convenient to use when you are away from your office.

Vanta Holster

Keep your Vanta analyzer safe and secure and within easy reach with the Vanta Holster. The Holster has a strap with a fastener to secure the instrument, MOLLE/PALS webbing for additional attachment options, and brass shielding.

Picture

Vanta Carry Case

Rugged, hard-shell case to securely transport your Vanta handheld XRF analyzer.

Picture

Resources

Application Notes

Case Studies

Insights

Product Resources