Eddy Current Titanium Probes
Overview
TEE/TEF - Attached/Detachable
The eddy current titanium probes offer ultimate durability with titanium protective cover for the coils and stainless steel wear guides at front and rear ends. They are ideal for heaters, coolers, and heat exchangers.
Features
- Ultimate durability.
- Titanium protective cover for coils.
- Stainless steel wear guides at the front and rear ends.
- Ideal for heaters, coolers, and heat exchangers.
Faster is better - Available for shortest delivery times
The probes listed below are regularly stocked for quick delivery. If the probe you require is not indicated, consider the alternate options with slight diameter and frequency variations, which won't affect the quality of your results. (See the Faster is Better sections on pp. 7 and 9 for more details.)
Part ID
Item Number
Diameter
Center Frequency
(kHz)
(kHz)
TEE-140-050-N20
U8280463
14mm
0.551in.
50 (Mid)
TEE-140-250-N20
U8280464
14mm
0.551in.
250 (High)
TEE-148-005-N20
U8280411
14.8mm
0.583 in.
5 (Very Low)
TEE-148-050-N20
U8280465
14.8mm
0.583 in.
50 (Mid)
TEE-148-250-N20
U8280466
14.8mm
0.583 in.
250 (High)
TEE-156-015-N20
U8280403
15.6mm
0.614 in.
15 (Low)
TEE-156-250-N20
U8280467
15.6mm
0.614 in.
250 (High)
TEE-182-015-N20
U8280620
18.2mm
0.717 in.
15 (Low)
TEE-182-050-N20
U8280621
18.2mm
0.717 in.
50 (Mid)
TEE-200-015-N20
U8280631
20mm
0.787 in.
15 (Low)
TEE-204-015-N20
U8280468
20.4mm
0.803 in.
15 (Low)
TEE-204-250-N20
U8280632
20.4mm
0.803 in.
250 (High)
Standard/Custom Probes (Made to Order)
Use the following nomenclature and the chart below to configure your part number.
Probe Type
Probe Diameter *†
(use mm in part ID)
(use mm in part ID)
Center Frequency
Cable Length
(TEE only)**
(TEE only)**
TEE: Attached
TEF: Detachable
Use with TEZ-BBS or TEZ-BBK cables.**
TEF: Detachable
Use with TEZ-BBS or TEZ-BBK cables.**
Standard
TEE: 9.6 mm to 50 mm
TEF: 11 mm to 50 mm
by 0.2 mm
Custom (TEE only)
50.2 mm to 100 mm
TEE: 9.6 mm to 50 mm
TEF: 11 mm to 50 mm
by 0.2 mm
Custom (TEE only)
50.2 mm to 100 mm
Standard
TEE: 0.378 in. to 1.969 in.
TEF: 0.433 in. to 1.969 in.
by 0.008 in.
Custom (TEE only):
1.976 in. to 3.937 in.
TEE: 0.378 in. to 1.969 in.
TEF: 0.433 in. to 1.969 in.
by 0.008 in.
Custom (TEE only):
1.976 in. to 3.937 in.
001 (Very Low)
015 (Low)
050 (Mid)
250 (High)
600 (Very High)
015 (Low)
050 (Mid)
250 (High)
600 (Very High)
15 m (50 ft)
20 m (65 ft)
30 m (100 ft)
20 m (65 ft)
30 m (100 ft)
**TEZ cable information for TEF probes is available in the Tube Inspection Probe Catalog.
† Note that probes with a diameter over 25.4 mm (1.00 in.) come with a stainless steel 316-grade protective cover for the coils instead of a titanium protective cover.
† Note that probes with a diameter over 25.4 mm (1.00 in.) come with a stainless steel 316-grade protective cover for the coils instead of a titanium protective cover.