Delay Line Transducers

Thickness and Flaw Inspection Solutions

Contact Us

A replaceable delay line transducer is a single element contact transducer designed specifically for use with a replaceable delay line.

Advantages:

  • Heavily damped transducer combined with the use of a delay line provides excellent near surface resolution
  • Higher transducer frequency improves resolution
  • Improves the ability to measure thin materials or find small flaws while using the direct contact method
  • Contouring available to fit curved parts

Applications:

  • Precision thickness gaging
  • Straight beam flaw detection
  • Inspection of parts with limited contact areas
  • Replaceable Delay Line Transducers
  • Each transducer comes with a standard delay line and retaining ring
  • High temperature and dry couple delay lines are available
  • Requires couplant between transducer and delay line tip

Delay Line Transducers

Frequency

Element Size

Colspan=2

Transducer
Part Numbers
MHz
inches
mm
2.25
0.25
6
V204-RM
5.0
0.50
0.25
13
6
V206-RM
V201-RM
10
0.25
0.125
6
3
V202-RM
V203-RM
15
0.25
6
V205-RM
20
0.125
3
V208-RM

Replaceable Delay Line Options

Nominal Element Standard
Delay Line
High Temperature Dry Couple
Delay Line
Spare
Retaining
Ring
Spring
Loaded
Holders
350°F Max
(175°C)
500°F Max
(260°C)
900°F Max
(480°C)
inches mm
0.50 13 DLH-2 DLHT-201 DLHT-2 DLHT-2G DLS-2 DRR-2 2130
0.25 6 DLH-1 DLHT-101 DLHT-1 DLHT-1G DLS-1 DRR-1 2127 & DRR-1H
0.125 3 DLH-3 DLHT-301 DLHT-3 DLHT-3G DLS-3 DRR-3 2133 & DRR-3H

Sonopen

Sonopen® Replaceable Delay Line Transducer

  • Focused replaceable delay line
  • Extremely small tip diameter may improve performance on curved surfaces and small indentations
  • Handle for easier positioning of transducer head

Frequency Nominal
Element
Size
Transducer
Part Numbers
MHz inches mm Straight
Handle
Right Angle
Handle
45°
Handle
15 0.125 3 V260-SM V260-RM V260-45

Sonopen Replaceable Delay Lines

Tip diameter Part Number
inches mm
0.080 2.0 DLP-3
0.060 1.5 DLP-302
0.080 2.0 DLP-301*

Spring Loaded Holder

SLH-V260-SM*

Harisonic Pencil

Harisonic Pencil Transducers

These high frequency, focused delay line transducers are compatible with any ultrasonic instrument capable of displaying a return echo at depths as low as .010 inches in steel. The typical range is approximately from .010 inches to 0.250 inches in steel. The 0.060 inches circular contact face enables readings to be taken on curved surfaces. Typical applications for these transducers include the inspection of turbine blades, small diameter tubing and concave areas in small parts. Both transducers utilize replaceable delay tips. For best performance, a short cable (such as MB type, 6') should be used. These models, indicated by a part number ending with an "L", incorporate PowerLink™ Technology to assure optimal performance when used with a Sonic ultrasonic instrument.

The HC-876 ultrasonic transducer operates at high frequency (20 MHz) with a broad bandwidth and small contact surface. Its chief application is thickness measuring of critical components such as jet engine blades. It is fitted with a Microdot connector.

Replaceable Delay Line

Frequency Nominal Element Size Part Number
(MHz) in. mm Straight Handle Right Angle Handle
10 0.125 3 HC-398-RDL-L HC-398-RA-RDL-L
Replacement Tips (10 ms) HAX-398 HAX-398

HC-398-RDL-L Straight Handle

HC-398-RA-RDL-L Right Angle Handle

Permanent Delay Line
Frequency Nominal Element Size Part Number
(MHz) in . mm Straight Handle Right Angle Handle
20 0.125 3 HC-876-L HC-876*
HC-876-RA-L
Permanent Tip Delay (10 ms) *Not PowerLink compatible.

HC-876-L Straight Handle

HC-876-RA-L Right Angle Handle

HC-876*Right Angle Handle

Permanent Delay Line

Permanent Delay Line Transducers with Handle Assembly

These transducers are used to reach into areas of limited access such as adjacent turbine blades. The swivel head improves contact in tight areas.

Frequency Nominal
Element Size
Delay Line
Length
Transducer
Part Number
MHz inches mm µsec
20 0.125 3 1.5 M2054
20 0.125 3 4.5 M2055
20 0.125 3 4.0 V2034