Use of Handheld XRF in Gold (Au) Mine Laboratories: Analysis of Pins, Mill Feeds, and Precipitates

Introduction

Evident handheld X-ray Fluorescence (XRF) analyzers provide high-performance, real-time data for rapid elemental analysis of metallic samples such as Gold (Au) pin samples as well as mill feeds, precipitates, and environmental samples within gold mines.

The DELTA handheld XRF analyzer is used by laboratory personnel as a screening tool and in some cases as replacement for fire assay techniques. Advances in XRF detector technology and signal processing have improved the precision, the limits of detection, increased the number of elements that can be measured, and vastly reduced analysis test times.

These analyzers can provide a rapid return on investment in a gold mine site laboratory.

Handheld XRF vs Fire Assay – Au


Handheld XRF vs Fire Assay – Au

Benefits of Handheld XRF are:

Handheld XRF vs Fire Assay – Au


Handheld XRF vs Fire Assay – Au

Handheld XRF vs Fire Assay – Au

Handheld XRF vs Fire Assay – Au

Return on Investment

Evident DELTA Handheld XRF analysis has been used as a screening tool and is now being used in some cases as a replacement technique for Gold (Au) and Silver (Ag) fire assays in gold mine laboratories. Linear regression analysis and other comparison studies (above), demonstrate outstanding agreement between XRF and fire assay techniques for the analysis of Au and Ag content within refinery pin samples. Cost savings are realized from reduced preparation and analytical time, labor cost reduction, and lack of reagent consumption when compared to fire assay analysis. Examples from one mine demonstrate preparation and analysis time can be reduced from 2 hours using traditional fire assay methods to 2 minutes using handheld XRF. Testing with the XRF simply involves rolling (flattening) the pin and performing multiple short tests (10 seconds in some cases) at different places on the pin and calculating the average.

Handheld XRF vs Fire Assay – Au

Improvement in Laboratory Safety, Industrial Hygiene and Environmental Performance

1. Laboratory Safety

2. Industrial Hygiene

3. Environmental Performance

Mill Feeds, Precipitates, and Bullion Penalty Elements

Prodotti per l'applicazione

Analizzatore XRF portatile DELTA

Gli analizzatori XRF portatili DELTA assicurano veloci analisi elementari non distruttive dal Mg all'U, dalle PPM fino al 100%. Usato in campo per ottenere dei risultati immediati, permette di pianificare le operazioni successive quando e dove necessario. È ideale effettuare delle analisi XRF portatili quando il tempo è un fattore limitante o quando il materiale non può essere trasportato, danneggiato o alterato.

DELTA Professional

Il DELTA Professional dotato di un rilevatore SDD e un tubo a raggi X ottimizzato da 4 W, assicura performance superiori per la velocità, i limiti di rilevamento o lo spettro elementare. Permette l'analisi del Mg e degli elementi a maggior numero atomico nelle leghe e nei minerali. Il DELTA Professional rappresenta la soluzione Evident a maggior valore aggiunto per gli analizzatori XRF.

Analizzatori XRF portatili DELTA per il settore minerario e geochimico

Gli analizzatori XRF portatili DELTA per il settore minerario e geochimico DELTA forniscono dei risultati immediati in ausilio all'elaborazione del piano di azione per l'intero processo: esplorazione, controllo del processo e della composizione minerale, della sostenibilità ambientale. Rilevamento dei metalli, dei minerali e dei contaminanti in campo. Funzioni XRF-GPS-GIS per la cartografia istantanea del metallo ed un'economia in termini di tempo e costi.