BondMasterプローブキット

非破壊検査ソリューション

メールでのお問い合わせ

製品の在庫状況は地域によって異なります。 詳細については、オリンパスの営業所までお問い合わせ下さい。

概要

BondMasterプローブ&標準キット

製品型番
アイテムナンバー
内容
9323977
Q6700011
BondMaster Starter Probe and Reference Sample Kit. Contains: External Alarm Booster, VGA Cable, Screen Protectors (10 Pack), 600 Series Soft Instrument & Accesory Case, Couplant, Backing Foam, Probe, Pitch/Catch: S-PC-P14, Probe, MIA: S-MP-3, Probe, Resonance: S-PR-5, Reference Standard: NEC-6433, Reference Standard: NEC-6407, Reference Standard: NEC-6382, Reference Standard: NEC-6384, Teflon Tape (1 inch wide), Cable, Model SBM-CR-P6, Cable, Model SBM-CPM-P11, B600 Kit Case, capable of storing instrument with protective soft cover installed.
BM-KIT-PC1
U8010069
BondMaster probe and Standard Kit for Pitch-Catch Inspections, Contains: NEC-6407 Reference Standard with S-PC-P14 Ptich Catch probe and cable.
BM-KIT-PC2
U8010070
BondMaster probe and Standard Kit for Pitch-Catch Inspections, Contains: NEC-6407 Reference Standard with S-PC-P14 and SPO-5629PHV Pitch Catch probes and cable.
BM-KIT-MIA
U8010071
BondMaster Probe and Standard Kit for MIA Inspections, Contains: Contains: NEC-6407 Reference Standard with S-MP-3 MIA Probe and BMM-H Spring Holder and cable.
BM-KIT-RES-C
U8010072
BondMaster Probe and Standard Kit for Resonance Inspections, Contains: NEC-6382 Compositive Reference Standard with S-PR-4 Resonance probe, couplant and cable.
BM-KIT-RES-A
U8010073
BondMaster Probe and Standard Kit for Resonance Inspections, Contains: NEC-6384 Aluminum Reference Standard with S-PR-4, couplant and cable.
BM-KIT-PMR
U8010074
BondMaster Probe and Standard Kit for Pitch-Catch, MIA and Resonance Inspections, Contains: NEC-6407 Reference Standard, S-PC-P14 and SPO-5629PHV Pitch-Catch Probes, S-MP-3 MIA Probe with BMM-H Spring Holder, NEC-6382 Composite Reference Standard, NEC-6384 Aluminum Reference Standard S-PR-4 REsonance probe, couplant and cables.
Basic Probe Kit
9317813
Contains: S-MP-3 Standard size tip; BMM-H Probe housing; S-PC-P11 Pitch-catch probe; S-PR-4 165 kHz resonance probe; SBM-CPM-P11 Cable (P-C and MIA); SBM-CR-P6 Cable (resonance); Couplant (4 oz) for use with resonance probes; Probe case
Probe Kit
9317814
Contains: S-MP-3 Standard size MIA probe; S-MP-4 Small MIA probe; BMM-H probe housing; S-PC-P11 Pitch-catch probe; S-PR-3 110 kHz resonance probe; S-PR-5 250 kHz resonance probe; SBM-CR-P6 Cable (resonance); Couplant (4 ox) For use with resonance probes; Probe case
Deluxe Probe Kit
9322158
Contains: S-MP-3 Standard size MIA probe; S-MP-4 Small MIA probe; BMM-H Probe housing; S-PC-P11 Pitch-catch probe; S-PC-P12 Pitch-catch probe; S-PR-3 110 kHz resonance probe; S-PR-5 250 kHz resonance probe; SBM-CPM-P11 Cable (P-C and MIA); SBM-CR-P6 Cable (resonance); Probe case
Air Force Probe Kit
9322078
Contains: S-PR-1 35 kHz Resonance probe, S-PR-2 65 kHz Resonance probe, S-PR-3 110 kHz Resonance probe, S-PR-4 165 Resonance probe, S-PR-5 250 kHz Resonance probe, S-PR-6 330 kHz Resonance probe, S-PC-P1 Pitch-catch probe, low voltage; S-PC-P12 Pitch-catch probe, high voltage; S-MP-5 Internal spring MIA probe; SBM-CPM-P11 Cable (P-C and MIA), SBM-CR-P6 Cable (Resonance); Teflon Tape 1/4 in. wide roll; Couplant 4 oz. (For use with Resonance probes)