Evident' DELTA range of Portable X-Ray Fluorescence (XRF) Analyzers continue to lead the way in real time, in-field geochemical analysis. Custom built for exploration and mining specific applications, the DELTA hosts a powerful 4W X-ray Tube coupled with an application optimized anode and silicon drift detector providing the lowest possible Limits of Detection (LOD's) in the shortest possible analysis times. With a workable LOD of 2-4 ppm for both Uranium Thorium, the DELTA provides unparalleled performance for the Uranium Explorer with quantification at or below the same level as the average crustal abundance for Uranium (typically around 2-4 ppm U)

The DELTA's 3-Beam Soil Mode provides both the power and flexibility to tailor your analytical requirements in line with the geochemical signatures of the deposit style you are searching for, with access to a range of over 30 analytes. Whether you are exploring for Calcretes, Phosphorites or Unconformity-related style Uranium mineralization, the DELTA arrives configured with an effective pathfinder element suite which includes P, V, Ni, As, Mo Base Metals plus the ability to analyze Light Elements with the addition of 2-Beam Mining Mode. This added versatility enables analysis of Whole Rock Litho-Geochemistry and Alteration assemblages and can include Mg, Al, Si, P, S, K, Ca in addition to standard Mining Mode elements.

Delta Handheld XRF Analyzer testing a rock outside
Summary Geochemical Signatures
Deposit Type Geochemical Signatures
Unconformity-related Nl, Pb, Co, As, B, Mo
Sandstone Mo, Se, Ti, S, Fe
Breccia Complex (IOCG) Fe, Cu, Au, Ag, Ba, F & REE
Quartz-Pebble Conglomerate Ti, Au, Ag, REE, Fe, S, PGE, Ni, Co
Calcretes (Surficial) V
Phosphorite P, F
Other Uranium Deposit Types Include: Vein, Intrusive, Volcanic & Caldera-related, Metasomatic, Collapsed Breccia Pipe, Lignite & Black Shales
Table Source: ioGlobal Geochemistry Workshop - Oct 2008

Data sample result graphs

관련 제품


https://main--eds-evident-website--evident-scientific.aem.live/ko/xrf-xrd/delta-handheld/delta-prof/

DELTA 프로페셔널

실리콘 드리프트 검출기(SDD)와 4W 최적화된 X선 튜브를 결합한 DELTA 프로페셔널은 속도, LOD 및 원소 범위에서 뛰어난 성능을 제공합니다. 합금 및 광업에 대해 Mg 등을 분석합니다. DELTA 프로페셔널은 Evident의 휴대용 XRF를 위한 최고의 가치를 지닌 솔루션입니다.


https://main--eds-evident-website--evident-scientific.aem.live/ko/xrf-xrd/delta-handheld/delta-mining/

DELTA 광업 및 지구화학용 휴대용 XRF 분석기

DELTA 광업 및 지구 화학용 휴대용 XRF 분석기는 즉각적인 결과를 제공하여 탐사, 광석 등급/공정 제어, 환경 지속 가능성 등 전체 프로세스에 대한 다음 작업 과정을 결정하는 데 도움이 되는 결과를 제공합니다. 현장의 금속, 광물 및 오염물질 탐지, 즉각적인 금속 매핑, 시간 및 비용 절감을 위한 GPS-GIS-XRF.