Inspecting small-diameter pipes can be challenging. One common application where NDT technicians can have a difficult time is inspecting flow iron. Flow iron is a type of flowback pipe used in certain mining applications. Phased array technology is a preferred method of corrosion inspection in flow iron pipes because of its speed and accuracy. However, when the flow iron pipe has a small diameter, it’s difficult to detect corrosion on the inside diameter (ID).

A customer asked us to develop a solution for inspecting for corrosion in 2 in. and 2.39 in. outside diameter (OD) pipes. Our Dual Linear Array™ (DLA) probes are a good choice for this application because of their large beam coverage, fast scan speed, C-scan imaging with a high data-point density, and removable wedges.

DLA probe being used to inspect a piece of flow iron for corrosion.

When using phased array probes to scan for corrosion on small-diameter pipes, coupling can become an issue—it can be difficult for the probe to maintain good contact with the pipe’s surface. Since the DLA probes have removable wedges, we were able to custom manufacture 2 in. and 2.3 in. OD wedges for the customer. Attaching these wedges to a DLA probe provided excellent coupling with no probe rocking.

The benefits of using DLA probes for inspecting small-diameter pipes include:

This example demonstrates that DLA probes with removable wedges are an effective solution for corrosion inspection on small-diameter pipes. Check out this video to learn more about what DLA probes can do.

Post Author's Photo

Sarah Williams

전속 작가

Sarah Williams는 거의 10년 동안 방송 산업에서 연구자 및 카피라이터로 일했습니다. 이제 Sarah는 작가 및 편집자로서 역량을 발휘하여 Evident의 다양한 비파괴 검사(NDT) 솔루션과 관련된 주제에 관해 흥미롭고 뛰어난 자료를 작성하고 있습니다. 그녀는 최신 원격 육안, 현미경, 초음파, 와전류 및 위상 배열 기술에 관한 글을 씁니다. 또한 이러한 기술의 응용 현황과 더불어 우리의 삶의 질과 세상의 안전을 향상하는 데 이러한 기술이 어떻게 기여하는지를 탐구합니다. Sarah는 파트너인 David 및 세 자녀 Sophie, Anouk 그리고 Éloi와 함께 퀘벡에 있는 사무실에서 근무하고 있습니다.