스폿 프로브

두께 및 결함 검사 솔루션

연락처

\

개요

Spot probes are used for discovering flaws both on and below surfaces. Available in a broad frequency range, their diameters are usually large for accommodating lower frequencies or scanning large areas. Because spot probes contain large coil diameters the detectable flaw size is increased and is typically equal to one-half of the probe diameter.

Detachable surface probes are available in a variety of diameters and frequency ranges. They are shielded to provide maximum sensitivity and are used for crack detection, thickness measurement, and conductivity and coating thickness measurements. These probes include a Fischer/LEMO Triax or 7-pin LEMO Powerlink™ quick-release connector.

Corrosion probes (SPO-532x series) are specifically balanced to detect material loss in aluminum structures, and they are configured with reflection absolute coils.

Standard Bridge

Type
Series
Frequency
Diameter
Connector
Part ID
Item #
Spot Probes
Standard Bridge
5 kHz - 100 kHz
6.3 mm (0.25 in.)
Triax Fischer/LEMO
9213546
U8623001
Spot Probes
Standard Bridge
100 kHz - 500 kHz
6.3 mm (0.25 in.)
Triax Fischer/LEMO
9216541
U8623011
Spot Probes
Standard Bridge
1 kHz - 50 kHz
7.9 mm (0.31 in.)
Triax Fischer/LEMO
9213012
U8630003
Spot Probes
Standard Bridge
500 Hz - 40 kHz
11.2 mm (0.44 in.)
Triax Fischer/LEMO
9213547
U8623002
Spot Probes
Standard Bridge
400 Hz - 30 kHz
12.7 mm (0.50 in.)
Triax Fischer/LEMO
9219548
U8629536
Spot Probes
Standard Bridge
300 Hz - 10 kHz
15.7 mm (0.62 in.)
Triax Fischer/LEMO
9213011
U8630002
Spot Probes
Standard Bridge
100 Hz - 2 kHz
19.0 mm (0.75 in.)
Triax Fischer/LEMO
9213549
U8623004
Spot Probes
Standard Bridge
5 kHz - 100 kHz
6.3 mm (0.25 in.)
Powerlink™ / 7-Pin LEMO
9222196
U8626007
Spot Probes
Standard Bridge
1 kHz - 50 kHz
7.9 mm (0.31 in.)
Powerlink™ / 7-Pin LEMO
9222161
U8626004
Spot Probes
Standard Bridge
500 Hz - 40 kHz
11.2 mm (0.44 in.)
Powerlink™ / 7-Pin LEMO
9222456
U8626012
Spot Probes
Standard Bridge
400 Hz - 30 kHz
12.7 mm (0.50 in.)
Powerlink™ / 7-Pin LEMO
9222457
U8629298
Spot Probes
Standard Bridge
300 Hz - 10 kHz
15.7 mm (0.62 in.)
Powerlink™ / 7-Pin LEMO
9222193
U8626006
Spot Probes
Standard Bridge
100 Hz - 2 kHz
19.0 mm (0.75 in.)
Powerlink™ / 7-Pin LEMO
9222192
U8626005

Standard Reflection

Type
Series
Frequency
Diameter
Connector
Part ID
Item #
Spot Probes
Standard Reflection
2 kHz - 200 kHz
6.3 mm (0.25 in.)
Triax Fischer/LEMO
9213550
U8623005
Spot Probes
Standard Reflection
2 kHz - 200 kHz
6.3 mm (0.25 in.)
Triax Fischer/LEMO
9213550
U8623005
Spot Probes
Standard Reflection
700 Hz - 80 kHz
7.9 mm (0.31 in.)
Triax Fischer/LEMO
9213551
U8623006
Spot Probes
Standard Reflection
400 Hz - 60 kHz
11.2 mm (0.44 in.)
Triax Fischer/LEMO
9213552
U8623007
Spot Probes
Standard Reflection
300 Hz - 40 kHz
12.7 mm (0.50 in.)
Triax Fischer/LEMO
9213553
U8623008
Spot Probes
Standard Reflection
100 Hz - 20 kHz
15.7 mm (0.62 in.)
Triax Fischer/LEMO
9213554
U8623009
Spot Probes
Standard Reflection
100 Hz - 5 kHz
19.0 mm (0.75 in.)
Triax Fischer/LEMO
9213555
U8623010
Spot Probes
Standard Reflection
2 kHz - 200 kHz
6.3 mm (0.25 in.)
Powerlink™ / 7-Pin LEMO
9222201
U8626011
Spot Probes
Standard Reflection
700 Hz - 80 kHz
7.9 mm (0.31 in.)
Powerlink™ / 7-Pin LEMO
9222200
U8626010
Spot Probes
Standard Reflection
400 Hz - 60 kHz
11.2 mm (0.44 in.)
Powerlink™ / 7-Pin LEMO
9222199
U8626009
Spot Probes
Standard Reflection
300 Hz - 40 kHz
12.7 mm (0.50 in.)
Powerlink™ / 7-Pin LEMO
9222198
U8626008
Spot Probes
Standard Reflection
100 Hz - 20 kHz
15.7 mm (0.62 in.)
Powerlink™ / 7-Pin LEMO
9222160
U8626003
Spot Probes
Standard Reflection
100 Hz - 5 kHz
19.0 mm (0.75 in.)
Powerlink™ / 7-Pin LEMO
9222458
U8626013

Corrosion Probes

Type
Series
Frequency
Diameter
Connector
Part ID
Item #
Spot Probes
Corrosion Probes
2 kHz - 200 kHz
6.3 mm (0.25 in.)
Triax Fischer/LEMO
9218204
U8629537
Spot Probes
Corrosion Probes
700 Hz - 80 kHz
7.9 mm (0.31 in.)
Triax Fischer/LEMO
9217896
U8633004
Spot Probes
Corrosion Probes
500 Hz - 60 kHz
11.2 mm (0.44 in.)
Triax Fischer/LEMO
9218108
U8633005
Spot Probes
Corrosion Probes
300 Hz - 40 kHz
12.7 mm (0.50 in.)
Triax Fischer/LEMO
9218203
U8629128
Spot Probes
Corrosion Probes
2 kHz - 200 kHz
6.3 mm (0.25 in.)
Powerlink™ / 7-Pin LEMO
9230395
U8629538
Spot Probes
Corrosion Probes
700 Hz - 80 kHz
7.9 mm (0.31 in.)
Powerlink™ / 7-Pin LEMO
9222343
U8633012
Spot Probes
Corrosion Probes
500 Hz - 60 kHz
11.2 mm (0.44 in.)
Powerlink™ / 7-Pin LEMO
9230403
U8629157
Spot Probes
Corrosion Probes
300 Hz - 40 kHz
12.7 mm (0.50 in.)
Powerlink™ / 7-Pin LEMO
9230404
U8633001