용접 프로브

두께 및 결함 검사 솔루션

연락처

Overview

Weld probes offer a cost effective method to inspect in-service ferrous welds. The inspection method is a clean, non-hazardous alternative over magnetic particle inspection, which does not require the removal of coatings such as paint or oxidation. Weld probes offer sensitivity to flaws in varying orientations and may also be used as a general purpose surface probe on any ferrous material.
Rotating Scanner Probe

Probes

Type
Series
Frequency
Tip Diameter
Overall Length
Connector
Part ID
Item Number
Weld Probe
Straight Weld probe
100 kHz - 600 kHz
5.0 mm (0.196 in.)
6.1 mm (2.4 in.)
4-Pin LEMO
WLD-5-63
U8690018
Weld Probe
Straight Weld probe
100 kHz - 600 kHz
8.0 mm (0.314 in.)
5.5 mm (2.16 in.)
4-Pin LEMO
WLD-8-55
U8690019
Weld Probe
Right Angle Weld Probe
100 kHz - 600 kHz
5.0 mm (0.196 in.)
5.0 mm (1.96 in.)
4-Pin LEMO
WLD901-5-50
U8690022
Weld Probe
Right Angle Weld Probe
100 kHz - 600 kHz
8.0 mm (0.314 in.)
5.0 mm (1.96 in.)
4-Pin LEMO
WLD901-8-50
U8690023
Weld Probe
Paint Thickness Probe
5 kHz – 250 kHz
6.35 mm (0.25 in.)
10.1 mm (4.0 in.)
4-Pin LEMO
NEC-2236
U8690035
Weld Probe
Straight Weld probe
100 kHz - 600 kHz
5.0 mm (0.196 in.)
6.1 mm (2.4 in.)
Powerlink™ / 7-Pin LEMO
9403362
U8629270
Weld Probe
Straight Weld probe
100 kHz - 600 kHz
8.0 mm (0.314 in.)
5.5 mm (2.16 in.)
Powerlink™ / 7-Pin LEMO
9403356
U8690033
Weld Probe
Right Angle Weld Probe
100 kHz - 600 kHz
5.0 mm (0.196 in.)
5.0 mm (1.96 in.)
Powerlink™ / 7-Pin LEMO
9403373
U8629539
Weld Probe
Right Angle Weld Probe
100 kHz - 600 kHz
8.0 mm (0.314 in.)
5.0 mm (1.96 in.)
Powerlink™ / 7-Pin LEMO
9403374
U8690038
Weld Probe
NECP-1152 SS W/45° Probe Tip
100 kHz - 1 MHz
7.9 mm (0.312 in.)
14.0 mm (5.5 in.)
Powerlink™ / 7-Pin LEMO
9231109
U8629540
Weld Probe
SPO-4376 Straight Weld Probe
100 kHz - 1 MHz
8.3 mm (0.330 in.)
8.2 mm (3.25 in.)
Powerlink™ / 7-Pin LEMO
SPO-4376L
U8629541
Weld Probe
Paint Thickness Probe
100 kHz - 600 kHz
6.35 mm (0.25 in.)
10.1 mm (4.0 in.)
Powerlink™ / 7-Pin LEMO
9403361
U8629269
Weld Probe
Straight Weld probe
100 kHz - 600 kHz
5.0 mm (0.196 in.)
6.1 mm (2.4 in.)
Triax Fischer/LEMO
WLD-5-63-TF
U8690046
Weld Probe
Straight Weld probe
100 kHz - 600 kHz
8.0 mm (0.314 in.)
5.5 mm (2.16 in.)
Triax Fischer/LEMO
WLD-8-55-TF
U8690047
Weld Probe
Right Angle Weld Probe
100 kHz - 600 kHz
5.0 mm (0.196 in.)
5.0 mm (1.96 in.)
Triax Fischer/LEMO
WLD901-5-50-TF
U8629542
Weld Probe
Right Angle Weld Probe
100 kHz - 600 kHz
8.0 mm (0.314 in.)
5.0 mm (1.96 in.)
Triax Fischer/LEMO
WLD901-8-50-TF
U8690048
Weld Probe
NECP-1152 SS W/45° Probe Tip
100 kHz - 1 MHz
7.9 mm (0.312 in.)
14.0 mm (5.5 in.)
Triax Fischer/LEMO
9231110
U8629184
Weld Probe
SPO-4376 Straight Weld Probe
100 kHz - 1 MHz
8.3 mm (0.330 in.)
8.2 mm (3.25 in.)
Triax Fischer/LEMO
9218631
U8629543
Weld Probe
Paint Thickness Probe
5 kHz – 250 kHz
6.35 mm (0.25 in.)
10.1 mm (4.0 in.)
Triax Fischer/LEMO
NEC-2236-TF
U8629544