Immersion transducer accessories aid in immersion applications and techniques. Accessories include bubblers, immersion tanks, reflective mirrors and search tubes.
Reflective Mirrors
- Directs sound beam when a straight-on inspection is not possible
- Standard mirrors provide a 90° reflection of the sound beam
| Case Style | Incident Angle | Part Numbers |
| (°) | ||
| Standard | 45 | F102 |
| Slim Line | 45 | F132 |
| Pencil | 45 | F198 |
Note: Contact us for other reflected angles.
Bubblers (RBS, Handheld)
- Allows for immersion testing when complete immersion of parts is not desirable or possible
- Designed to maintain a consistent, low volume flow of water
| Part Numbers | Diameter Opening | Water Path | Case Style | Nominal Element Size | Opening Type | |||
| inches | mm | inches | mm | inches | mm | |||
| MPF-B-0.5 | 0.300 | 7.6 | 1.00 | 25.4 | Standard SU | 0.125 | 3 | flat |
| 0.25 | 6 | flat | ||||||
| B103 | 0.350 | 8.9 | 0.775 | 19.7 | Standard SU | 0.125 | 3 | V-notch |
| 0.25 | 6 | V-notch | ||||||
| B103A | 0.350 | 8.9 | 0.475 | 12.1 | Standard SU | 0.125 | 3 | flat |
| 0.25 | 6 | flat | ||||||
| B103W | 0.550 | 14 | 0.775 | 19.7 | Standard SU | 0.375 | 10 | V-notch |
| 0.50 | 13 | V-notch | ||||||
| B103AW | 0.550 | 14 | 0.475 | 12.1 | Standard SU | 0.375 | 0.375 | flat |
| 0.50 | 13 | flat | ||||||
| B116 | 0.100 | 2.5 | variable, min. of: | Fits SU/RM case style | 0.125 | 3 | flat | |
| 0.075 | 1.9 | 0.25 | 6 | flat | ||||
| B117 | 1.375 | 34.4 | 1.400 | 35.6 | Large Diameter | 1.00 | 25.4 | V-notch |
RBS-1 Immersion Tank
RBS-1 immersion tank is designed to simplify testing measurements using immersion techniques. It consists of a clear acrylic tank, a submersible pump and a transducer fixture in a single, portable unit. The pump feeds an adjustable stream of water to a bubbler mounted in the fixture, providing a water column to couple sound from an immersion transducer into the test piece. It is ideal for offline thickness measurements on metal, glass and plastic products such as small containers, pipe or tubing, sheets or plates or machined parts.
Clear Acrylic Tank
- 5.5 x 12 x 8 inches (140 x 305 x 200 mm)
- 0.83 gallon (3.1 liter) capacity
Pump
- Up to 0.25 gallons (0.9 liters) per minute
- 115 or 230 V, 30 Watt (voltage range 90 to 135 VAC), 50 to 60 Hz
- Submersible (ground fault interrupter circuit recommended)
Handheld Bubbler Transducer Assembly
Handheld bubbler transducers are available in either 20 MHz (V316B) or 10 MHz (V312B). They are immersion transducers that screw onto a bubbler assembly (B120) which has a replaceable stainless steel tip and a water feed tube. They offer high resolution and easy access inspection of thin materials. The V316B and bubbler combination can resolve thicknesses down to 0.008" (0.2 mm).
| Frequency | Nominal Element Size | Focal Length | Transducer Part Number | Bubbler Assembly | Replacement Tip | Flexible Tip | ||
| MHz | inches | mm | inches | mm | ||||
| 10 | 0.25 | 25 | 1.00 | 25 | V312B-RM | B120 | B120-TIP | B120-FLEX-TIP |
| 20 | 0.125 | 3 | 0.75 | 19 | V316B-RM | B120 | B120-TIP | B120-FLEX-TIP |
Immersion Search Tubes
- Provides a quick and easy way to fixture and manipulate immersion transducers
---
| Part Numbers | Length | Fits Connector Styles | Outside Diameter | ||
| inches | mm | inches | mm | ||
| F112 | 1.5 | 38 | UHF to UHF | 0.738 | 18.75 |
| F113 | 2 | 51 | UHF to UHF | 0.738 | 18.75 |
| F114 | 3 | 76 | UHF to UHF | 0.738 | 18.75 |
| F115 | 6 | 152 | UHF to UHF | 0.738 | 18.75 |
| F116 | 8 | 203 | UHF to UHF | 0.738 | 18.75 |
| F117 | 12 | 305 | UHF to UHF | 0.738 | 18.75 |
| F118 | 18 | 457 | UHF to UHF | 0.738 | 18.75 |
| F119 | 24 | 610 | UHF to UHF | 0.738 | 18.75 |
| F120 | 30 | 762 | UHF to UHF | 0.738 | 18.75 |
| F211 | 12 | 305 | Microdot ® to Microdot | 0.312 | 7.92 |