Spot weld transducers are specifically designed to provide optimal performance for nondestructive testing of numerous types of spot welds, including those used in automotive and industrial applications.

Evident IMS ultrasonic spot weld transducers are specifically designed to provide optimal performance for nondestructive testing of numerous types of spot welds, including those used in automotive and industrial applications. Ultrasonic inspection of spot welds involves the analysis of what is known as the "ringdown" of sound within the weld nugget. Unlike many other direct measurement techniques, spot-weld inspection looks at the characteristics of the multiple echoes returned from sound energy ringing within the weld nugget. Echo spacing, sound attenuation, and intermediate echo detection are some of the indicators of weld quality that are analyzed by trained inspectors.

Our transducers have excellent signal-to-noise ratios due to broadband design, which is critical for distinguishing good welds from poor welds. These transducers are available in a multitude of sizes in 0.5 mm increments to ensure that the proper transducers are available for a variety of weld nugget sizes. Element sizes are engraved with both English and metric units for worldwide use. The versatile design of these spot weld transducers allows them to be used with either a soft membrane captive water column or a hard tip delay line. Transducers, delay lines, and water columns are sold separately.

Spot Weld Transducers

Top Row: Transducer, Water Column, Membranes Bottom Row: Transducer, Delay Line, Delay Line Retaining Ring

Frequency
Nominal Element Size
VIDEOSCAN
(MHz)
in.
mm
Part /
Item No.
15
0.118
3
V2330\U8415025
15
0.138
3.5
V2335\U8415026
15
0.157
4
V2340\U8415027
15
0.177
4.5
V2345\U8415028
15
0.197
5
V2350\U8415029
15
0.217
5.5
V2355\U8415030
15
0.236
6
V2360\U8415031
15
0.256
6.5
V2365\U8415032
15
0.315
8
V2380\U8415033
15
0.98
2.5
V2325\U8415024
20
0.098
2.5
V2425\U8415034
20
0.118
3
V2430\U8415035
15
0.138
3.5
V2335\U8415026
20
0.157
4
V2440\U8415037
20
0.177
4.5
V2445\U8415038
20
0.197
5
V2450\U8415039
20
0.217
5.5
V2455\U8415040
20
0.236
6
V2460\U8415041
20
0.256
6.5
V2465\U8415042

Captive Water Column Membranes (Includes O-Rings)

fits DLCW-1003
fits DLCW-2003
fits DLCW-3003
Part Number
Desc. (qty.)
Part Number
Desc. (qty.)
Part Number
Desc. (qty.)
DLCW-1003-MK25
25 Std.
DLCW-2003-MK25
25 Std.
DLCW-3003-MK25
25 Std.
DLCW-1003-MK50
50 Std.
DLCW-2003-MK50
50 Std.
DLCW-3003-MK50
50 Std.
DLCW-1003-MKX25
25 Hvy. Duty
DLCW-2003-MKX25
25 Hvy. Duty
DLCW-3003-MKX25
25 Hvy. Duty
DLCW-1003-MKX50
50 Hvy. Duty
DLCW-2003-MKX50
50 Hvy. Duty
DLCW-3003-MKX50
50 Hvy. Duty