Bobbin Probes
두께 및 결함 검사 솔루션
개요
TEA/TEB - Attached/Detachable
The eddy current bobbin probes are lightweight, economical, but solidly built probes with the coils protected with a plastic sleeve and stainless steel wear guides at front and rear ends. They are ideal for the inspection of heaters, coolers, and heat exchangers.
Features
- Lightweight, solidly built.
- Coils protected by a plastic sleeve.
- An economical solution.
- Stainless steel wear guides at front and rear ends.
- Ideal for heaters, coolers, heat exchangers, and more.
Faster is better - Available for shortest delivery times
The probes listed below are regulary stocked for quick delivery. If the probe you require is not indicated, consider the alternate options with slight diameter and frequency variations, which won't affect the quality of your results.
TEA (Attached) Stock Probes
| Part ID | Item Number | Diameter | Center Frequency kHz |
|
| mm | in. | |||
| TEA-118-015-N20 | U8280510 | 11.8 | 0.465 | 15 (Low) |
| TEA-118-050-N20 | U8280623 | 11.8 | 0.465 | 50 (Mid) |
| TEA-122-050-N20 | U8280614 | 12.2 | 0.480 | 50 (Mid) |
| TEA-126-015-N20 | U8280615 | 12.6 | 0.496 | 15 (Low) |
| TEA-140-005-N20 | U8280446 | 14 | 0.551 | 5 (Very Low) |
| TEA-140-050-N20 | U8280447 | 14 | 0.551 | 50 (Mid) |
| TEA-140-250-N20 | U8280214 | 14 | 0.551 | 250 (High) |
| TEA-148-005-N20 | U8280616 | 14.8 | 0.583 | 5 (Very Low) |
| TEA-148-050-N20 | U8280439 | 14.8 | 0.583 | 50 (Mid) |
| TEA-148-250-N20 | U8280212 | 14.8 | 0.583 | 250 (High) |
| TEA-156-015-N20 | U8280474 | 15.6 | 0.614 | 15 (Low) |
| TEA-156-250-N20 | U8280624 | 15.6 | 0.614 | 250 (High) |
| TEA-158-015-N20 | U8280625 | 15.8 | 0.622 | 15 (Low) |
| TEA-158-050-N20 | U8280450 | 15.8 | 0.622 | 50 (Mid) |
| TEA-158-250-N20 | U8280451 | 15.8 | 0.622 | 250 (High) |
| TEA-162-050-N20 | U8280626 | 16.2 | 0.638 | 50 (Mid) |
| TEA-180-050-N20 | U8280618 | 18 | 0.709 | 50 (Mid) |
| TEA-188-050-N20 | U8280452 | 18.8 | 0.740 | 50 (Mid) |
| TEA-200-050-N20 | U8280453 | 20 | 0.787 | 50 (Mid) |
| TEA-200-250-N20 | U8280218 | 20 | 0.787 | 250 (High) |
| TEA-208-050-N20 | U8280454 | 20.8 | 0.819 | 50 (Mid) |
| TEA-208-250-N20 | U8280216 | 20.8 | 0.819 | 250 (High) |
| TEA-228-600-N20 | U8280627 | 22.8 | 0.898 | 600 (Very High) |
TEB (Detachable*) Stock Probes
| Part ID | Item Number | Diameter Frequency | Center Frequency kHz |
|
| mm | in. | |||
| TEB-132-250 | U8280455 | 13.2 | 0.520 | 250 kHz (High) |
| TEB-134-050 | U8280457 | 13.4 | 0.528 | 50 kHz (Mid) |
| TEB-140-050 | U8280566 | 14 | 0.551 | 50 kHz (Mid) |
| TEB-148-015 | U8280459 | 14.8 | 0.583 | 15 kHz (Low) |
| TEB-148-050 | U8280628 | 14.8 | 0.583 | 50 kHz (Mid) |
| TEB-158-015 | U8280461 | 15.8 | 0.622 | 15 kHz (Low) |
| TEB-158-250 | U8280629 | 15.8 | 0.622 | 250 kHz (High) |
Standard/Custom Probes (Made to Order)
Use the nomenclature and the chart below to configure your part number.
| Probe Type | Probe Diameter (use mm in part ID) |
Center Frequency | Cable Length (TEA only)** |
|
| mm | in. | |||
| TEA: Attached TEB: Detachable (Use with a TEZ-BBS or TEZ-BBK cable.**) |
Standard TEA: 9.6 mm to 50 mm TEB: 11 mm to 50 mm by 0.2 mm Custom (TEA only) 6.6 mm to 9.4 mm 50.2 mm to 100 mm |
Standard TEA: 0.378 in. to 1.969 in. TEB: 0.433 in. to 1.969 in. by 0.008 in. Custom (TEA only): 0.260 in. to 0.370 in. 1.976 in. to 3.937 in. |
001 (Very Low) 015 (Low) 050 (Mid) 250 (High) 600 (Very High) |
15 m (50 ft) 20 m (65 ft) 30 m (100 ft) |
**TEZ cable information for TEB probes is available in the Tube Inspection Probe Catalog.