Wedges for Angle Beam Probes

Thickness and Flaw Inspection Solutions

Contact Us

Overview

Advantages

Wedge Specifications and Dimensions

Part Number
Probe Type
Nominal Refracted Beam Angle
(in Steel)
Recommended Sweep (°)
Probe Orientation
Wedge Dimensions (mm)
L
W
W*
H
SA00-0L
A00
0° LW
−30 to 30
Normal
16
12
N/A
12
SA00-N60S
A00
60° SW
40 to 70
Normal
21
14
N/A
13
SA0-0L
A0
0° LW
−30 to 30
Normal
23
12
N/A
11
SA0-N60S
A0
60° SW
40 to 70
Normal
32
18
N/A
21
SA1-0L
A1
0° LW
−30 to 30
Normal
29
30
30
20
SA1-N60S
A1
60° SW
40 to 70
Normal
30
30
40
16
SA1-N60L
A1
60° LW
40 to 70
Normal
28
30
40
21
SA2-0L
A2
0° LW
−30 to 30
Normal
65
30
40
20
SA2-N60L
A2
60° LW
40 to 70
Normal
79
30
40
50
SA2-N55S
A2
55° SW
40 to 70
Normal
69
30
40
43
SA3-0L
A3
0° LW
−30 to 30
Normal
38
37
50
20
SA3-N45S
A3
45° SW
40 to 60
Normal
55
37
50
30
SA3-N45L
A3
45° LW
30 to 60
Normal
55
37
50
49
SA3-N60S
A3
60° SW
40 to 70
Normal
58
37
50
32
SA3-N60L
A3
60° LW
40 to 70
Normal
53
37
50
40
SA4-0L
A4
0° LW
−30 to 30
Normal
59
47
55
20
SA4-N45S
A4
45° SW
40 to 60
Normal
90
47
55
51
SA4-N45L
A4
45° LW
30 to 60
Normal
88
47
55
85
SA4-N60S
A4
60° SW
40 to 70
Normal
86
47
55
45
SA4-N60L
A4
60° LW
40 to 70
Normal
83
47
55
68
SA5-0L
A5
0° LW
−30 to 30
Normal
38
45
55
20
SA5-N45S
A5
45° SW
40 to 60
Normal
57
47
55
37
SA5-N60S
A5
60° SW
40 to 70
Normal
46
43
55
25
SA5-N60L
A5
60° LW
40 to 70
Normal
39
50
55
41
SA10-0L
A10
0° LW
−30 to 30
Normal
25
23
40
20
SA10-N55S
A10
55° SW
40 to 70
Normal
23
23
40
14
SA10-N60L
A10
60° LW
40 to 70
Normal
26
23
40
30
SA11-0L
A11
0° LW
−30 to 30
Normal
35
23
40
23
SA11-N55S
A11
55° SW
40 to 70
Normal
41
23
40
29
SA11-N60L
A11
60° LW
40 to 70
Normal
43
23
40
53
SA12-0L
A12
0° LW
−30 to 30
Normal
58
23
40
20
SA12-N55S
A12
55° SW
40 to 70
Normal
73
23
40
45
SA12-N60L
A12
60° LW
40 to 70
Normal
61
23
40
53
SA14-0L
A14
0° LW
−30 to 30
Normal
80
23
40
20
SA14-N55S
A14
55° SW
40 to 70
Normal
96
23
40
49
SA15-N60S
A15
60° LW
40 to 70
Normal
18
22
N/A
12
SA16-N55S
A16
55° SW
40 to 70
Normal
85
31
40
44
SA31-0L
A31
0° LW
-30 to 30
Normal
40
30
40
20
SA31-N55S
A31
55° SW
40 to 70
Normal
49
30
40
32
SA31-N60L
A31
60° LW
40 to 70
Normal
39
30
40
31
SA32-0L
A32
0° LW
-30 to 30
Normal
50
30
40
20
SA32-N55S
A32
55° SW
40 to 70
Normal
62
30
40
33
SA32-N60L
A32
60° LW
40 to 70
Normal
56
30
40
43
SAWS1-N60S
AWS1
60° SW
40 to 70
Normal
45
38
N/A
32
SAWS1-0L
AWS1
0° LW
-30 to 30
Normal
38
38
N/A
40
SNW1-0L
NW1
0° LW
N/A
Normal
66
32
32
22
SNW1-0L-AQ25
NW1
0° LW
N/A
Normal
71
40
40
37
SNW1-0L-AQ25-WR
NW1
0° LW
N/A
Normal
93
40
40
39
SNW1-0L-IHC-C
NW1
0° LW
N/A
Normal
66
32
32
22
SNW2-0L
NW2
0° LW
N/A
Normal
26
32
32
22
SNW2-0L-AQ25
NW1
0° LW
N/A
Normal
31
40
40
37
SNW2-0L-AQ25-WR
NW1
0° LW
N/A
Normal
53
40
40
39
SNW3-0L
NW3
0° LW
N/A
Normal
130
32
32
22
SNW3-0L-AQ25
NW1
0° LW
N/A
Normal
135
40
40
37
SNW3-0L-AQ25-WR
NW1
0° LW
N/A
Normal
157
40
40
39
SPWZ1-0L
PWZ1
0° LW
-30 to 30
Normal
75
30
40
20
SPWZ1-N55S
PWZ1
55° SW
40 to 70
Normal
87
30
40
45
SPWZ3-0L
PWZ3
0° LW
-30 to 30
Normal
40
30
40
20
SPWZ3-N55S
PWZ3
55° SW
40 to 70
Normal
65
30
40
38
SPWZ3-N60L
PWZ3
60° LW
40 to 70
Normal
64
30
40
35
* Width with IHC wedge option

Standard Wedge Curvature Values

External Pipe Diameter

in.

Curvature Range
Minimum
mm (in.)
Maximum
mm (in.)
Wedge Type: SA1, SA2, SA3, SA4, SA5, SPWZ1, SPWZ3, SI1, SI2, SI3
2
45.7 (1.8)
50.8 (2)
2.25
50.8 (2)
57.1 (2.25)
2.5
57.1 (2.25)
63.5 (2.5)
3
63.5 (2.5)
76.2 (3)
3.25
76.2 (3)
82.5 (3.25)
3.5
82.5 (3.25)
88.9 (3.5)
4
88.9 (3.5)
101.6 (4)
4.5
101.6 (4)
114.3 (4.5)
5
114.3 (4.5)
127.0 (5)
6
127.0 (5)
152.4 (6)
7
152.4 (6)
177.8 (7)
8
177.8 (7)
203.2 (8)
10
203.2 (8)
254.0 (10)
12
254.0 (10)
304.8 (12)
16
304.8 (12)
406.4 (16)
22
406.4 (16)
555.8 (22)
30
558.8 (22)
762.0 (30)
Flat
762.0 (30)
up to flat
Wedge Type: SA10*, SA11*, SA12*, SA14*, SA31, SA32
2.375
50.8 (2)
60.3 (2.375)
2.875
60.3 (2.375)
73.0 (2.875)
3.5
73.0 (2.875)
88.9 (3.5)
4
88.9 (3.5)
101.6 (4)
4.5
101.6 (4)
114.3 (4.5)
5.563
114.3 (4.5)
141.3 (5.563)
6.625
141.3 (5.563)
168.3 (6.625)
8.625
168.3 (6.625)
219.0 (8.625)
10.75
219.0 (8.625)
273.0 (10.75)
12.75
273.0 (10.75)
323.8 (12.75)
16
323.8 (12.75)
406.4 (16)
24
406.4 (16)
609.6 (24)
Flat
609.6 (24)
up to flat
Wedge Type: ST and SPE
2
44.4 (1.75)
50.8 (2)
2.25
50.8 (2)
51.7 (2.25)
2.5
57.1 (2.25)
63.5 (2.5)
3
63.5 (2.5)
76.2 (3)
3.5
76.2 (3)
88.9 (3.5)
4
88.9 (3.5)
101.6 (4)
5
101.6 (4)
127.0 (5)
6
127.0 (5)
152.4 (6)
8
152.4 (6)
203.2 (8)
12
203.2 (8)
304.8 (12)
16
304.8 (12)
406.4 (16)
22
406.4 (16)
558.8 (22)
Flat
555.8 (22)
up to flat
* Below 4 in., IHC are integrated in the Rexolite and wedges are not compatible with IHC rings. Flat wedge can be used for pipes greater than 12.75 in. OD.

Options

Wedge Offset Parameters

How to Find the Wedge Parameters

  1. Find the appropriate wedge in either the OmniScan or TomoView Wedge Database. Parameters are automatically set once the wedge model is chosen.
  2. If the wedge is not already in the database, you may download the latest database update from the Service & Support section of https://ims.evidentscientific.com/.
  3. Enter the parameters manually using the values provided on the Wedge Specification Sheet accompanying the wedge.
  4. Call your local sales representative.

Wedge Curvature Conventions

Wedge parameters with OmniScan
X
Primary offset
Y
Secondary offset (0 when probe is centered)
Z
Height
Wedge parameters with TomoView
X T
Primary axis offset of the middle of the first element (mm)
Y
Secondary axis offset of the middle of the first element (mm) (measured from the side of the wedge)
Z
Height at the middle of the first element (mm)