Natural Gas Service Line Inspection Using Videoscopes

Natural Gas Service Line Inspection Using Videoscopes

Background:

Natural Gas service lines connect the distribution line, which runs parallel to the road, with the meter on a residential or business property. Older service lines have the potential to corrode that may result in the leaking of natural gas in residential areas. These older lines are currently being replaced with plastic pipelines that have various diameters although the ½ inch (12.7 mm) diameter is most common. The fittings on the plastic pipe are welded by heat fusion. This process can create very large weld joints in the interior of the pipe, thereby dramatically reducing the ID at the bends.

Challenges:

  1. The reduction in ID at the weld joints prevents industrial videoscopes with large diameter insertion tubes scopes from fitting through. This weld joint also requires an articulating scope to navigate over a large weld bead.
  2. As cracks and general signs of wear are the main targets for this inspection, image clarity is crucial.
  3. A videoscopes having a large focal range is required to both see the interior wall and down the length of a pipe for navigation.
  4. Often the entire length of a long service line with limited access points needs to be inspected.
  5. Durability of the scope’s insertion tube and tip is crucial given the tight bends and articulation that is required.

Benefits:

  1. Evident has a 30 meter articulating scope in 8.5 mm (and 6 mm up to 18 m) to ensure the entire line is inspected even if the weld joints have a reduced ID.
  2. The TrueFeel feature (6 mm) and Pneumatic articulation (8.5 mm) provide great maneuverability even at 30 meters.
  3. In order to deliver a very clear and high quality image, LED’s at the tip or the powerful laser located in the base provide maximum light onto the weld area.
  4. Image clarity combined with a very wide focal range enables very efficient inspections of the interior wall as well as effortless navigation in long and curved pipes.
  5. Evident’s insertion tube construction is uncompromised. Despite the long length, you still get full durability to assure maximum uptime.

相关产品


https://main--eds-evident-website--evident-scientific.aem.live/zh/rvi-products/iplex-nx/

IPLEX NX

高端的工业视频内窥镜系统地组合了多种先进功能,使用更具便捷性与耐久性。从高画质检测到外来异物的抓取,多样化的性能带给用户前所未有的体验。


https://main--eds-evident-website--evident-scientific.aem.live/zh/rvi-products/iplex-gair/

IPLEX GAir

IPLEX GAir视频内窥镜可帮助用户快速轻松地到达远距离检查目标。IPLEX GAir视频内窥镜配备30 m(98 ft)和20 m(65 ft)插入管、气动导向、实时图像定位以及能够精确导向并采集高质量图像的其他功能,帮助检查人员快速高效地到达目标。