概览
TER - Detachable
The eddy current Airgun probes are extremely lightweight. It is designed to work with the MPP04-01 Airgun probe pusher-puller. It features a grooved design to reduce pushing force in tube end and to improve durability. It is ideal for steam condensers, coolers, and heat exchangers.
Recommendations
TER probes are designed be used with the Airgun scanner to speed up ECT inspection (4 m/s to 6 m/s push speed, and 2 m/s encoded pull speed).
The MPP04-01 Airgun
Features
- Extra lightweight.
- Designed to work with the MPP04-01 Airgun probe pusher-puller.
- Grooved design to reduce pushing force in the tube end and improve durability.
- Ideal for steam condensers, coolers, and heat exchangers.
Standard/Custom Probes (Made to Order)
Use the nomenclature and the chart below to configure your part number.
| Probe Type | Probe Diameter (use mm in part ID) |
Center Frequency | Cable Length** | |
| mm | in. | |||
| TER: Airgun probe Use with a TEZ-BBG cable.** |
Standard 14 mm to 31.6 mm by 0.2 mm Custom*** 11.4 mm to 13.8 mm |
Standard 0.551 in. to 1.244 in. by 0.008 in. Custom*** 0.449 in. to 543 in. |
15 (Low) 050 (Mid) 250 (High) 600 (Very High |
20 m (65 ft) 30 m (100 ft) |
| **TEZ Kevlar cable information for TER probes is available in the Tube Inspection Probe Catalog. ***Custom TER probes with diameters below 14 mm require the AEIX0818 custom nozzle. |
||||