Active Pharmaceutical Ingredient (API) Confirmation with X-ray Diffraction



Evident X-ray diffraction (XRD) analyzers can be used to identify pharmaceuticals and unknown substances such as narcotics and counterfeit medication. Evident XRD analyzers can be used in the field or a controlled laboratory environment for safe, fast analysis of hazardous materials.
Fast results with Evident technology
Evident XRD instruments use leading-edge and reliable technology employed in NASA’s Curiosity Rover, part of the successful NASA Mars Science Laboratory program.
While the TERRATM and BTX-II analyzers use identical powder-XRD technology to identify compounds. The BTX-II is a small benchtop unit for laboratory investigation. The Terra actually operates both as electric, or battery-operated for up to five hours. Both analyzers are equipped with a unique, patented powder-handling system that utilizes small powder quantities with little sample preparation (less than 15 mg).
Comparison plots of XRD patterns
Advantages of XRD
- Detect and identify narcotics, counterfeits, and unknown materials
- Safe, fast analysis of hazardous material
- Easy-to-use instruments for field or lab analysis
- Closed beam operation for user safety
- Portable or benchtop diffractometer
Identifying Unknown Compounds
Pharmaceuticals: Detecting Counterfeits
- Rapid identification of counterfeit pharmaceuticals
- Detect the presence of active and inactive ingredients as well as foreign and substitute materials
- Help ensure patient safety and safeguard pharmaceutical manufacturer’s branding

XRD data analysis reveals the presence of filler materials (gypsum and basanite) in a blue pill expected to contain a popular name brand drug
Customs: Narcotics Identification
Police and legal teams need a fast, conclusive method to detect illegal substances. Evident XRD analyzers provide rapid compound identification of unknown substances. Narcotics have unique XRD fingerprints that can be used to identify suspect materials.
- Fast, easy sample preparation and analysis for rapid results
- Sample spinner cell is safe for analyzing potentially hazardous materials
- Sealed cell enables samples to be archived for future analysis
Safe and Easy Sample Preparation
Our unique sample spinner design enables safe, easy handling of hazardous substances.
- Small sample size—approximately 15 mg
- Minimal preparation—no additional grinding required
- Sealed sample cell—safe for volatiles
- Archivable samples—sealed sample cells can be stored for future evidence