Automated Surface Inspection Using Eddy Current Array Technology

Introduction

Inspecting the surface of long bars and tubes has been a requirement in the metal manufacturing industry for many years. Material quality and performance requirements are continuously evolving with respect to the various types, orientations, and sizes of surface indications. While different technologies can be used to detect surface defects, eddy current array (ECA) stands out due to its ability to adapt to various geometries and deviations on both ferromagnetic and nonferromagnetic products.

Challenges

The tube and bar manufacturing process can disrupt the optimal product parameters by causing variations in the geometry (ovality, hooks, and bending) and surface conditions (pits, scale, and burrs). The part’s condition has a significant impact on the quality of the inspection. Therefore, the probe’s ability to maintain an optimal position during inspection while adapting to the part’s condition is critical.

Example of the rough surface condition found on many production bars

Solution

Evident ECA probe technology uses printed circuit boards (PCBs), enabling an increase in the lift-off distance while improving the inspection performance. This improvement enabled us to integrate a hard-ceramic face to the probe assembly to shield it from the tube or bar’s rough surface.

The probe’s technology and design enable the detection of longitudinal- and transverse-orientated flaws. Specific probe designs can detect flaws in any 360-degree orientation.

ECA probe with a ceramic face

ECA probe with a ceramic face for in-line tube or bar inspection

Evident ECA smart probes have embedded monitoring and live integrity validation features. They are accessible via the acquisition unit software interface and enable users to get detailed health information and live status updates about the most critical components of the inspection systems. In a turnkey solution, these features can be used to evaluate the probe’s scan-to-scan detection integrity to set or raise alarms that warn of out-of-tolerance conditions during an inspection or to facilitate diagnostics.

Results

Depending on the application, the probe, wedge, and shoe are specifically designed to fit the part being inspected to improve the assembly’s durability.

To test the design, we mounted a probe to a complete mechanical assembly that mimicked the normal operating conditions for in-line tube and bar inspection.

Example of a mechanical assembly

Example of a mechanical assembly

Over 3000 km (1864 miles) of long metal parts were inspected at various speeds of up to 2 meters/second. Only minor damage, mostly scratches, could be seen on the probe’s ceramic face. No performance variation or degradation were measured when comparing inspection results from before and after the test.

Ceramic face of an ECA probe showing minor abrasions post testing

Ceramic face of an ECA probe showing minor abrasions post testing

Conclusion

This next-generation ECA probe’s rugged design offers durability and versatility for manufacturing inspection applications.

The use of eddy current array brings many advantages to surface inspection, including:

BIS ECA: Bar Inspection System—Eddy Current Array

This BIS uses eddy current array (ECA) technology to inspect the entire surface of round and square bars. The system’s actuators automatically adapt the ECA probe positions to the product shape and size and accommodate any surface irregularities. Robust wear shoes protect the probes from shocks and abrasion.

RBIS: Rotating Bar Inspection System

The RBIS combines phased array and eddy current array technologies to inspect the full volume and surface of large round bars called billets. The inspection is carried out during the rotation of the billet and the linear movement of the carriage supporting inspection head.

RTIS: Rotating Tube Inspection System

The RTIS uses phased array technology to inspect the full body of tubes. The system is based on the “Water Wedge” concept using a membrane to maintain a permanent and stable water chamber providing a fast coupling and short untested length.