Calibration of an Entire Range of Oblique Defects with the Gapless Method

Introduction

The seamless tube manufacturing process can generate flaws in various angles around the longitudinal axis of a tube. These flaws, introduced primarily during the lamination or heat treatment process, can cause the tube to fail while in use, potentially leading to catastrophic economic and social impacts.

Challenges

To ensure the integrity of their products, seamless tube manufacturers must maintain stringent quality standards. For this reason, they need to use the most reliable and precise inspection methods available. However, many conventional automated phased array ultrasonic testing (PAUT) tube inspection systems assume that the manufacturing process generates flaws at certain discrete angles, which is not always the case.

Commonly used firing and receiving angles for oblique inspection


Commonly used firing and receiving angles for oblique inspection

With the current PAUT method, to ensure inspection coverage for a range of oblique angles, the reference standard used for calibration would need to contain several notches at different angles, and each of them would need to be calibrated individually.

Solution

The gapless inspection solution provided by the Evident Rotating Tube Inspection System (RTIS) manages to overcome the hurdle of calibrating for flaw detection without a reference notch for each oblique orientation. The gapless method uses only one transmitting angle for a range of oblique reference notches but covers the target area completely with a higher number of receiving channels.

Gapless firing and receiving for continuous oblique inspection


Gapless firing and receiving for continuous oblique inspection

Using the same pipe map used today to calibrate discrete oblique orientation, the gapless method takes a highresolution scan of each artificial flaw and creates a powerful scan for every angle, enabling extrapolation of the missing notches. From each curve, shape parameters are extracted and compared to create the normalization curve in the figure below. This curve gives us the virtual notch response for each angle of the range.

High-resolution scan for standard calibration notch (before normalization)

High-resolution scan for standard calibration notch (before normalization)

Calibration targets for each receiving channel are automatically updated when setup parameters change, so the calibration sequence and the results displayed remain unchanged compared to existing discrete oblique inspection using phased array.

Results

In the figure to the right, the normalization curve (solid black line) is set at a constant calibration level, setting the offset gain required for each receiving channels. Calibration targets are also displayed, using the maximum point where a notch curve (solid line) crosses the Rx channel position (red dotted line).

High-resolution scan for standard calibration notch (before normalization)

High-resolution scan for standard calibration notch (before normalization)

Calibration of each receiving channel is performed using the existing notches and can be displayed in 2D using the RTIS Top Turn device. This 2D visualization reduces calibration time as it enables the manufactured defects to be located at the same axial position.

Using this method, calibration results can be predicted and then validated with simple tests; for example, when scanning an intermediate notch (not used for calibration), the normalization curve level can be confirmed.

Oblique notch detection for intermediate angles (scrolling views and 2D mapping data, alarms)

Oblique notch detection for intermediate angles (scrolling views and 2D mapping data, alarms)

Conclusion/Key Benefits

Because the gapless solution offered by the Evident RTIS is just as simple to perform as the current calibration method, even medium-skilled operators can do it. It is systematized, automated, and repeatable.

Evident’ proven QuickScan™ LT hardware already has the capability to perform gapless inspection, so existing systems can be easily upgraded to this new technology. Users can also choose whether or not to activate the gapless function, according to the strictness and precision level required for a particular pipe batch.