Small Diameter Tube and Pipe Inspection with Time-of-Flight Diffraction (TOFD)

Introduction

Small diameter tube and pipe inspection can be difficult. Challenges include the fact that pipe-to-pipe clearance is typically very small; access to the pipe is limited to only one side; and the wall thickness and diameter are quite small, making typical phased array (PA) probes unusable. Because of the size of the probes and scanners, radiography was typically preferred over phased array and conventional ultrasound methods.

Phased array offers several advantages over radiography when it comes to inspecting small diameter tubes and pipes. Often, a series consecutive inspections are required, so the system that is being used must be able to provide repeatable results one inspection after the other. Small diameter tube and pipe inspection systems also must fast and capable of quickly moving from one inspection area to the next. The Evident COBRA® scanner was optimized to overcome the traditional limitations of phased array inspection for small diameter tubes and pipes with features including:

Solution

The COBRA scanner phased array solution offers a fast, practical system for small diameter pipe and tube inspection. By using ultrasonic technology, users can avoid the inherent difficulties and disadvantages that accompany radiographic inspection, such as safety concerns, regulatory issues, the technique’s slow speed, and the need to clear people out of the inspection area during testing.

Evident’ 80° TOFD wedges further enhance the capabilities of the COBRA solution. While keeping the advantages of the COBRA scanner discussed above, the TOFD technique is a cost-effective solution that is very sensitive to volumetric defects in small diameter pipes.

TOFD is a well-established technique that has a long history of use for general weld inspections. It has proven to be a fast and easily deployable method with an excellent capacity for sizing. One of the inherent strengths of TOFD for detection and sizing purposes is its relative indifference to the orientation of defects because of its primary use of diffracted versus reflected energy.

Ultrasonic transducers are positioned on each side of the weld; one transducer sends the ultrasonic signal into the material and the other receives reflected and diffracted ultrasound from discontinuities and geometric reflectors. TOFD provides a wide area of coverage with a single beam by exploiting ultrasonic beam spread theory inside the wedge and the inspected material. When the ultrasound signal comes in contact with the tip of a flaw, or crack, diffracted energy is cast in all directions. Measuring the time of flight of the diffracted beams enables accurate and reliable flaw detection and sizing, even if the crack is off-oriented to the initial beam direction.

The kit of COBRA TOFD wedges includes one pair of flat wedges plus nine pairs of curved wedges to cover pipes with an OD range of 1.05 in. to 4.5 in. The wedges are designed to fit ST1 probes with 3 mm diameter elements. Note that the use of these wedges will increase the minimum clearance required for the use of the COBRA scanner compared with the phased array option.

Equipment Used

Conclusion

The COBRA scanner with TOFD technology provides a cost-effective, efficient, and reliable testing method capable of meeting the challenges associated with inspecting small diameter tubes and pipes. When paired with the OmniScan SX UT flaw detector, the end result is a comprehensive record of inspection data conveniently stored in an electronic format that can be re-opened and analyzed at any time. The evolution of the discontinuities encountered during an inspection can be monitored over time, enabling inspectors to determine a trend and plan for preventive maintenance.

Although radiography is the most commonly used technique for this application, the ultrasound techniques discussed here offer many advantages in terms of safety, the probability of detection, and the speed of inspection.

Summary of key benefits

TomoView Software

TomoView is a powerful and flexible PC-based software used for design, data acquisition, visualization, and analysis of ultrasonic signals.

OmniPC 4 Software

This software is the most efficient and affordable option for OmniScan MX2 and SX data analysis, and features the same analysis tools provided in the MX2 and SX onboard software, with the added flexibility of running on a personal computer.

OmniScan SX

The single group, lightweight OmniScan SX flaw detector features an easy-to-read 8.4-inch (21.3 cm) touch screen and provides cost-effective solutions. The OmniScan SX comes in two models: the SX PA and SX UT. The SX PA is a 16:64PR unit, which, like the UT-only SX UT, is equipped with a conventional UT channel for P/E, P-C, or TOFD inspections.

COBRA Scanner

The COBRA™ manual scanner combined with the OmniScan X3 flaw detector is used to perform circumferential welding inspections on small-diameter pipes. The COBRA small-diameter scanning unit can hold two PA probes to inspect pipes with ODs ranging from 0.84 to 4.5 in.