Application Notes
Thickness Gaging of Fiberglass Boat Hulls
Ultrasonic thickness measurements are particularly useful with fiberglass mat or roving lay-ups. Variations in layer thickness make it necessary to periodically check thickness. Sometimes boat hulls are made of fiberglass skins sandwiched around an inner core of balsa wood, cork, or foam. In those cases, the core material does not transmit ultrasound, making it impossible to take total hull thickness measurements. However, the outer fiberglass layers can be measured very effectively with ultrasonic equipment.
Equipment Used for Fiberglass Thickness Measurements of Boat Hulls
The 39DL PLUS™ and 45MG thickness gauges with the High Penetration software option are capable of making digital thickness measurements on fiberglass. They are commonly used with an M2008 transducer (500 kHz) to maximize the penetration of ultrasound in thick or attenuating fiberglass, providing an approximate thickness measurement range of 0.15 in. to 3 in. (4 mm to 75 mm), depending on the type of fiberglass.
In especially challenging cases, the 39DL PLUS thickness gauge with the high penetration transducer option and large waveform display is recommended. This configuration enables operators to adjust setup parameters on-site. Transducers such as the M1036 (2.25 MHz) or M109 (5 MHz) can measure down to approximately 0.05 in. (1.25 mm) in fiberglass.
Procedure for Measuring Fiberglass Hull Thickness
The 39DL PLUS and 45MG thickness gauges with the High Penetration option both have pre-programmed default setups for the two transducers commonly used for fiberglass measurement: the M2008 and M1036. In many cases, these default setups can be used with no further adjustment, just the two-point velocity and zero calibration that is recommended for all ultrasonic thickness measurements.
The fiberglass used in boat construction is generally of high quality. Unlike some other fiberglass laminates, it usually does not produce high amplitude internal reflections that can cause false readings. However, if false readings are observed in a particular case, the situation can usually be corrected by small adjustments of the initial gain and TDG slope as outlined in the gauge operating manuals. The 39DL PLUS thickness gauge waveforms below show a typical hang up on internal reflections and a correct reading of total hull thickness following a simple gain adjustment.
False reading due to a hang up on internal reflections
Correct reading following gain adjustment
Any delaminations that may occur in the hull will appear as strong, well-defined reflectors accompanied by a complete loss of the back wall echo. While ultrasonic flaw detection should always be performed with instruments specifically designed for that purpose, such as the EPOCH™ series, a trained operator can use the waveform display of the 39DL PLUS and 45MG gauges to make initial judgments about the presence of delaminations in a hull.
Gelcoat measurement: A closely related application is measuring the smooth gelcoat applied over fiberglass. For detailed information on ultrasonic measurement of gelcoat thickness, please refer to our application note, Measurement of Fiberglass Gelcoat.
Related products
39DL PLUS
The 39DL PLUS™ gauge is field-proven and reliable for virtually every ultrasonic thickness inspection. It works as a precision or corrosion thickness gauge to meet the challenges of demanding applications across industries, including maintenance, manufacturing, and energy production. With world-class ultrasonic capability, fast scanning speeds, and fully integrated wireless connectivity, this handheld gauge delivers results you can trust in a seamless workflow.
72DL PLUS
The 72DL PLUS™ advanced ultrasonic thickness gauge delivers precision thickness measurements at high speed in a portable, easy-to-use device. Compatible with single element transducers up to 125 MHz, this innovative instrument is ideally suited to measure the thickness of ultra-thin materials, including multilayer paint, coatings, and plastic. It can simultaneously display the thickness of up to 6 layers.
45MG
The handheld 45MG ultrasonic thickness gauge is packed with measurement features and software options. This unique instrument is compatible with the complete range of Evident dual element and single element transducers, making this gauge an all-in-one solution for virtually every thickness gauge application.