Stream Live Waveforms with the 39DL PLUS Streaming PC Application
In nondestructive testing (NDT) environments, a 'second opinion' shouldn’t have hurdles. The free 39DLP Streaming PC application removes the barriers to collaboration, allowing users to stream, troubleshoot, and document measurements directly on their PC in real-time.
The 39DLP Streaming PC application is a free collaboration software tool designed to extend the capabilities of the 39DL PLUS™ thickness gauge by enabling real-time waveform streaming directly to a PC.
Whether supporting field inspections, troubleshooting applications, or training team members, this application helps streamline communication and improve decision-making without requiring additional hardware.
Watch the tutorial video to learn more about the 39DL Plus Streaming PC Application
Real-Time Waveform Streaming to Your PC
The 39DLP Streaming PC application enables live waveform viewing from the 39DL PLUS thickness gauge directly on a computer. Users can connect:
- Via a standard USB cable
- Wirelessly using the instrument’s built-in Wi-Fi
Because the software does not require external video conversion hardware, setup is straightforward. Any 39DL PLUS thickness gauge user with a PC and a standard USB connection can begin streaming quickly and efficiently.
Remote Control for Enhanced Collaboration
In addition to waveform viewing, the application enables remote control of the 39DL PLUS thickness gauge from the connected PC. Users can adjust most keypad functions (including Gain, Blanking, Measurement and Application parameters) remotely ensuring optimal application setup.
This capability supports collaboration across multiple locations. For example, a field technician can join a video conference, share their PC screen, and allow a colleague to view live data and make real-time adjustments to their instrument.
This functionality is well suited for:
- Remote application troubleshooting
- Cross-site collaboration
- Internal knowledge sharing
- Technical support from Evident
Full Transducer Adjustment Control
The 39DLP Streaming PC application supports full transducer adjustment control when using:
- Single-element transducers
- Dual-element transducers
This flexibility supports a wide range of thickness measurement applications, including corrosion monitoring, maintenance inspections, and quality control processes.
Dual-element transducer adjustment control on the 39DLP Streaming PC application
Designed for Application Support and Training
The 39DLP Streaming PC application is particularly useful for application support and operator training due to its video conferencing capability. It supports:
- Remote technical assistance from Evident
- Mentoring by experienced team members
- Training new operators
- Multi-site inspection coordination
Rapid and Complete Data Management
Waveforms and screen captures can be saved directly from the PC, simplifying documentation for reports, quality records, and further analysis.
- Key Features at a Glance
- Real-time live waveform streaming to a PC
- Remote control of the 39DL PLUS thickness gauge
- On-screen keypad for instrument operation
- Direct saving of waveform and screen captures
- No additional video hardware required
- Free download from the Evident website
Improve Efficiency with Remote Thickness Gauge Streaming
By combining the portability of the 39DL PLUS thickness gauge with the connectivity of the 39DLP Streaming PC application, teams can reduce downtime, improve communication, and strengthen application support capabilities.
To download the 39DLP Streaming PC application, visit the Evident website and begin streaming measurements in real time.