5 XRF Accessories for Your Mining and Geochemical Analysis Field Kit
Handheld XRF analyzers can provide immediate, on-site elemental measurements for a range of mining and geochemical analysis applications, including mineral exploration, ore grade control, and environmental monitoring.
While these XRF analyzers may come with everything you need to start testing at the mines or field site (as shown in our Vantaâ„¢ unboxing video), they can be enhanced with optional accessories. Here are five practical XRF accessories for mining and geochemical analysis:
1. Vanta Work Station
The Vanta Work Station is a fully interlocked system that enables you to set up your handheld XRF analyzer on a benchtop or as a portable field laboratory. Simply power on the system, click the analyzer into place, close the lid, and start the test through a wireless connection or USB. While the test runs, you can perform other tasks and stay productive.
This setup is useful for mining and geochemistry applications that may require longer test times, such as mining process control, geological exploration, and environmental analysis. Other benefits include:
- Works on battery or AC power for benchtop or field testing
- Convenient for bagged, prepped, and liquid samples or small objects
- Consistent sample positioning
- Easy storage and transport: the chamber and legs separate, and an optional carry case is available
The Vanta Work Station
See how it works in this video:
2. Vanta Soil Foot
Another helpful tool for hands-free analysis is the Vanta Soil Foot, which provides a stable three-point support for your XRF analyzer. This compact, cost-effective accessory is useful for the longer test times required in some mining and geochemical analysis applications.
The Vanta Soil Foot supports the XRF analyzer as it rests on the ground
3. Vanta Field Stand
If you need to test small items such as samples in cups or bags, then look no further than the Vanta Field Stand. The lightweight, portable test stand and shielded sample chamber are easy to set up, use, and pack away in just a few steps.
The Vanta Field Stand for testing small samples
To see how easy it is to set up the Field Stand, Soil Foot, and related accessories, watch the video below:
4. Vanta Holster
Keep your XRF analyzer securely by your side and ready when you need it with the Vanta Holster. This practical fashion accessory includes:
- A strap with a fastener to secure the instrument
- MOLLE/PALS webbing to provide additional attachment options
- Brass shielding to protect against X-ray exposure
The Vanta Holster offers hands-free transport of your XRF analyzer
5. Vanta Transport Case
All Vanta handheld XRF analyzers come with a rugged, hard-shell transport case that can endure tough mining and field conditions.
Explore XRF Accessories for Mining and Geochemical Analysis
If these XRF accessories look useful for your application, you can easily order them online at our webstore. For more mining and geochemistry tips, be sure to check out our Vanta geochem technical tutorial series.