SteerROVER Motorized Scanner
Rugged and portable, the SteerROVER™ motorized scanner is an easy-to-operate steerable magnetic scanning solution. Steer the scanner at a distance using the robust handheld remote controller with its easy-to-read touch screen. Leverage the SteerROVER scanner to simplify inspections of large ferromagnetic surfaces, such as pressure vessels and tanks, and achieve reliable phased array (PA) ultrasonic testing of areas that are difficult to reach.
SteerROVER™ Scanner for Weld Inspection and Corrosion Mapping
Rugged and portable, the SteerROVER™ motorized scanner is an easy-to-operate steerable magnetic scanning solution. Steer the scanner at a distance using the robust handheld remote controller with its easy-to-read touch screen. Leverage the SteerROVER scanner to simplify inspections of large ferromagnetic surfaces, such as pressure vessels and tanks, and achieve reliable phased array (PA) ultrasonic testing of areas that are difficult to reach.
Configurations
The SteerROVER scanner can be ordered in different configurations depending on the application (weld or corrosion) and by combining different raster arm and cable length options.
The two-camera RECON kit can be added to the SteerROVER scanner to assist in navigating at a distance, keeping the weld well centered, and helping ensure that the probes remain in contact with the surface.
The SteerROVER scanner and probe holder rack can bend to perform inspection of longitudinal welds.
The SteerROVER scanner, when fitted with a motorized raster arm, is a powerful solution for corrosion inspection in remote locations.
Features
- Steerable scanner comprised of two pods with independent motors and four strong magnetic wheels.
- Touch screen remote with two joysticks; configurable so that scanner movement requires constant user input (jog) or so that one input starts the scanner and a second stops it.
- Two automatic raster scan patterns are available.
- Can be ordered with different choices of motorized raster arms for corrosion inspection or a probe holder rack for weld inspection with four probes (increase to six probes with optional probe holders).
- Emergency-stop buttons located on the scanner and on the power controller.
- Divisible cable conduit umbilical offers cable protection and flexible configurations.
Standard Inclusions
- Steerable motorized scanner.
- Touch screen remote control.
- Power controller.
- Detachable umbilical cables with divisible protection sleeve.
- Encoder cable linking to OmniScan series flaw detectors (current generation) and FOCUS PX instruments.
- Irrigation tubing.
- Carrying case(s).
- Motorized raster arm or probe holder rack (depending on configuration).
Motorized Raster Arm:
- Spring-loaded probe holder compatible with the HydroFORM™ scanner, Dual Linear Array™ corrosion probes, and most phased array wedges equipped with IHC (irrigation, holes, and carbides).
Pivoting Probe Holder Rack:
- Four spring-loaded probe holders.
- Two adjustable yokes to hold phased array probes (up to 57.6 mm wide and 48.5 mm long).
- Two adjustable yokes to hold TOFD-P/E probes (up to 45 mm wide and 36.8 mm long).
RECON Camera System:
- Two cameras (main and satellite).
- Tablet with installed RECON Studio software and charger.
- 30 m cables linking camera to the tablet.
- Short cable to connect the satellite camera to the main camera.
- Bracket to mount the cameras to the SteerROVER scanner.