IPLEX TX II

The ultra-thin IPLEX TX II video borescope is available with a 2.2 mm diameter flexible scope or a 1.8 mm rigid scope. Using the flexible scope, you can obtain a wide field of view in spaces where the opening is very small for faster inspections and easier decision making. Combining high image quality and user comfort, the IPLEX TX II video borescope enables efficient inspection of castings, molds, and other parts with small cavities.

IPLEX TX II Videoscopes and Borescopes

Better Imaging in Small Spaces

The ultra-thin IPLEX TX II video borescope is available with a 2.2 mm diameter flexible scope or a 1.8 mm rigid scope. Using the flexible scope, you can obtain a wide field of view in spaces where the opening is very small for faster inspections and easier decision making. Combining high image quality and user comfort, the IPLEX TX II video borescope enables efficient inspection of castings, molds, and other parts with small cavities.

Repeatable RVI Results

The IPLEX TX II video borescope offers easier insertion to help you reach your target faster as well as improved image quality that supports your decision making.

IPLEX TX (predecessor)

IPLEX TX (predecessor)

See More

  • 120-degree field of view to observe a wide area at once, helping speed up inspections
  • High-pixel CMOS sensor delivers excellent image quality
  • Bright LED illumination enables you to see better in large spaces
  • Image adjustment methods—like image turning and halation reduction—make it easier to see in reflective areas and capture clear, low-noise images
  • Scene mode enables you to create two image setting configurations and toggle between them

IPLEX TX II

IPLEX TX II

Inspect in Smaller Spaces

  • Access small openings with the 2.2 mm insertion tube
  • Insertion tube with a 2 mm shorter rigid distal end compared to the original IPLEX TX combined with improved hardness and articulation control, making it easier to maneuver in smaller spaces
  • The insertion tube’s articulating section has a tungsten outer braid for added protection, while its shortened length help keep it from getting stuck
  • The rigid insertion tube's air injector enables you to blow liquid droplets away to obtain clearer images *

*The protection sleeve is required to use the air injector.

Stay Comfortable During Long Inspections

  • Ultra-lightweight rigid scope weighs as much as a ballpoint pen, so there’s less strain when you’re holding it for long periods of time
  • Extend the grip to grasp the tube closer to the insertion point for finer control
  • Images are displayed on a tablet, so you can position it where it’s comfortable
Rigid Scope hold

Durable and Flexible

Flexible scope unit

Rigid scope unit

Rigid scope unit

Specifications

Scope Unit

Model No. Flexible scope unit: IV10212TF Rigid scope unit: IV10212TR
Insertion tube Scope diameter Φ2.2 mm Φ1.8 mm
Scope length 1.2 m (3.9 ft) 180 mm (0.59 ft)
Distal end length*1 7.85 mm (0.31 in.) -
Exterior High durability metal braid with special processed resin -
Tube flexibility Uniform stiffness -
Optical system Direction of view Forward
Field of View 120°
Depth of field*2 3–80 mm
Articulation Section Articulation angle 120° (up/down) -
Articulation mechanics Direct manipulation -

Control Unit

Model No. IV10200T
Weight 350 g (0.77 lb)
Dimensions (L x Φ) 172 x 52 mm (6.77 × 2 in.)
Illumination High-intensity white LED
Power supply USB power supply
USB connector Type C connector, Version 2.0 standards

Operation Unit

Model.NO IV10-OPERATION
Weight 2.1kg
Dimensions (W x H x D) 300 mm × 230 mm × 49 mm (11.8 in. × 9.1in. × 1.9 in.) (protruding parts not included)
LCD Monitor 10.1-inch WUXGA (1920 × 1200), IPS, High contrast
Hard surface and multi-touch interface (10 point), capacitive
Daylight readable display (Optical bonding + AR coating) 1100 NIT-backlight
Video output Type A HDMI 2.0
Headset (microphone in/ audio out) Compatible with Bluetooth® headset/microphone
Data I/O Ports USB Type C Port x3
Power Supply 100 V to 240 V, 50/60 Hz (with supplied AC adaptor), 10.8V (with supplied battery)
Recording media Internal SSD (256 GB) or USB flash memory
Title Text Options 51-character display
Wi-Fi 2.4GHz (802.11 b/g/n/ax) x 2ch (Built in operation unit)
Bluetooth® Bluetooth® 5.2 × 1
IV10000にWiFiドングルを接続する事でIV10000を無線接続可能

Software Functions - IPLEX One App

Image manipulations 2x digital zoom, 12-step manual or 8-step auto brightness control
Gain control 2-step adjustable gain control (manual or auto)
Sharpness control 3-step adjustable sharpness control
Saturation control 3-mode adjustable color saturation (monotone, natural, vivid)
Overlay 51 character title, Zoom,Bright, Light date/time, Scene, Logo, Socpe serial
Still image recording Resolution H512 x V512 (Pixel)*
*When Print Screen is on, the resolution becomes H1280 × V800.
Recording format Compressed JPEG format, PNG format
Video recording Resolution H392 x V392 (Pixel)*
*When Print Screen is on, the resolution becomes H1280 × V800.
Recording format MPEG4 AVC/H.264 (.MP4 file)
Frame rate 30
Plan Displays the folder tree and lists thumbnails within the folders
File Copy, rename, delete, add mark, add title for file
Create, copy, rename, delete for folder
USB and internal flash storage
Inspection data synchronization with Evident Coneect using WiFi

Operating Environment

Operating temperature Insertion tube In air: -25 to 80 °C (-13 to 176 °F), In water: 10 to 30 °C (50 to 86 °F)
Other parts In air: -10 to 40 °C
Relative humidity All parts 15 to 90% (Relative Humidity)
Liquid resistance All parts Operable when exposed to machine oil, light oil, or 5% saline solution.
Waterproofing Insertion tube Operable underwater up to a water pressure equivalent to a depth of 1.2 m.
Other parts Operable in blowing rain conditions; not operable under water

*1 Indicates the length of the rigid portion at the scope's distal end.
*2 Indicates the viewing distance with optimal focus.

Accessories

Protection Braid for IV10212TF

Model No. MAJ-2537
Weight 5.6 g
Outer diameter φ2.8 mm (0.1 in.)
Braid length Approx. 1 m (3.3 ft)

Protection Sleeve for IV10212TR

Model No. MAJ-2538
Weight 2.85 kg (6.3 lb)
Outer diameter φ2.3 mm (0.09 in.)
Sleeve length 160 mm (0.5 ft)
Air tube outer diameter 4 mm
Maximum air pressure 0.7 Mpa

Grip Extender for IV10212TR

Model No. MAJ-2540
Weight 53 g (total of three)
Dimensions (L x Φ) 30 × 14 mm (1.2 × 0.6 in.), 48 × 14 mm (1.9 × 0.6)

Protection Box

Model No. MAJ-2536
Dimensions (W × D × H) 400 x 150 x 300 mm (excluding protrusion)
Weight 2.85 kg (6.3 lb)
Waterproofing IP52 dustproof and splashproof

Carrying Case

Dimensions (W × D × H) 455 x 185 x 330 mm (excluding protrusion)
Weight 2.1 kg (5 lb)

*Indicates the viewing distance with optimal focus.

*The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.

*Evident Corporationuses these trade markes and logos under license. All other trademarks and registered trademarkes are the property of their respective owners.

Tablets Tested for Compatibility

Microsoft Surface Pro9
Intel Core i5, 8 GB RAM, Windows 11 Pro (64 bit)
Panasonic FZ-G2
Intel Core i5, 8 GB RAM, Windows 11 Pro (64 bit)

· May not work when combined with other software.
· If you are going to use the IPLEX TX II software with a tablet other than those listed above, please refer to the recommended tablet specifications below.
· If you have any questions, please contact your local Evident representative.

CPU
Intel Core i5
RAM
8 GB or larger (dual channel)
HDD
8 GB free space or more
Display resolution
1280 × 800 or more
External terminal
USB TypeC
OS
Windows 11 Pro (64bit)
Others
IEC/EN60950-1 or IEC/EN62368-1 compliant

· We do not guarantee that the IPLEX TX II software will work on all tablets that meet the above criteria.

Software

ViSOL™ Visual Inspection Workflow Solution

Picture, Picture

Connecting You with More

Streamline your visual inspections with ViSOL. Designed to intuitively organize, analyze, and report inspection data, ViSOL delivers actionable insights with advanced analytics, clear visualization, and seamless collaboration. A fully scalable cloud software solution, ViSOL supports digital transformations for individuals and organizations at any scale.

Learn More

Resources

Insights

Product Resources