In-Line ERW High-Temperature Inspection System

This in-line PAUT process-control system is positioned between weld cooling and annealing to inspect ERW tube seams and HAZ. Its unique self-cooling wedge and automatic alarms protect the phased array probe from temperatures up to 100 °C (212 °F).

Fully Automated ERW Tube Process-Control

Overview

In-Line ERW High-Temperature Inspection System

ERW Solutions: In-Line ERW High-Temperature Inspection System

The In-Line ERW High-Temperature Inspection System integrates into the production line between the weld cooling and annealing, where the pipe temperature is 100 °C (212 °F) or lower. A special self-cooling wedge combined with automatic alarms protect the phased array (PA) probe against excessive temperatures.

Using conventional ultrasonic (UT) and PA technology, the system inspects the internal and external surfaces of the ERW seam and the heat-affected zone (HAZ) in pipes ranging from 60.3 mm to 508 mm (2.4 in. to 20 in.) OD. Automatic weld tracking technology connected to servomotor-driven mechanisms helps ensure coverage of the region of interest.

The following typical defects are detected:

  • Longitudinal cracks
  • Through-drilled holes
  • Lamination defects in the HAZ (up to 25 mm (1 in.) on each side of the weld)

Strict Standard Compliance for OCTG Tube Manufacturers

Completely automated, the In-Line ERW High-Temperature System’s phased array probe tracks and records the weld profile and the UT probes detect flaws in the welded area using the automatic positioning. This turnkey system gives ERW pipe manufacturers the tools to meet the inspection requirements of international standards:

Software and Acquisition Unit

Phased Array Acquisition Unit

The QuickScan™ PA 32:256 module meets IP55 standards and is designed to easily integrate into industrial environments.

Easy Setup and Data Management

QuickView™ software makes it easy to configure the system and acquire and manage data. The results are merged and displayed to clearly differentiate between accepted and rejected tubes.

  • Software wizard assists you in creating setups for different tube sizes
  • Quickly access predefined configuration and calibration parameters for each tube diameter
  • Restrict access to certain users to help minimize operator errors
  • Calibration and inspection information are stored for traceability
  • Offers an operating mode that requires minimal human intervention
QSLT

Real-Time Weld Profiling

QuickView software displays a complete weld profile view in real time without mechanical oscillation of the phased array probe.

Weld Profile Top View

Specifications

Standard Product Range Diameter 60.3 mm to 508 mm (2.375 in. to 20 in.)
Wall Thickness 3 mm to 16 mm (0.118 in. to 0.630 in.)
Speed Typically 600 mm/sec (limited by the production line speed)
Coverage 100% weld volume for cracks/TDH and up to 25 mm on each side of weld for lamination detection
Data Presentation Real-Time Inspection Results C-scan, A-scan, B-scan, strip charts, and alarms
Inspection Modes Typical Inspection Modes Longitudinal and lamination
Operating Temperature Up to 100°C
Detection Capabilities for Typical Reference Defects Repeatability Longitudinal notches: <3 dB; 3.2 mm TDH: <4 dB; 1.6 mm TDH: <5 dB; 6.35 mm FBH: <3 dB; 3.2 mm FBH: <4 dB
Standards ISO, API
Reporting and Data Storage Report Types Inspection, calibration, and calibration-check user-configurable reports
Storage Real-time database inspection data storage

System Performance