Tube Inspection Systems
Seamless and welded tube inspection system using ultrasonic phased array and X-ray fluorescence spectroscopy technologies.
LSAW Tube Inspection System
Longitudinal submerged arc welded (LSAW) tubes are manufactured by bending and molding steel plate and then joining the edges using a double-sided submerged arc weld. They are commonly used in the oil and gas industry for long-distance hydrocarbon transport pipelines.
TEIS: Tube End Inspection System
The TEIS is a high-quality yet small-footprint PA or UT inspection solution that minimizes untested lengths left by other tube inspection systems. It can be integrated into fully automated systems to meet stringent volume-inspection requirements.
Vanta™ iX In-Line XRF Analyzer
The Vanta iX in-line X-ray fluorescence (XRF) analyzer gives you confidence in your products by automating material analysis and alloy identification on the manufacturing line. Built to operate 24/7 in industrial environments, the system delivers instant results for 100% inspection and continuous quality control.
PipeWIZARD
The PipeWIZARD is an automated girth welding inspection system using phased array and conventional UT techniques (AUT). Specially designed for in-site weld-to-weld inspection in extreme environments, on-shore and off-shore.
RTIS: Rotating Tube Inspection System
The RTIS uses phased array technology to inspect the full body of tubes. The system is based on the “Water Wedge” concept using a membrane to maintain a permanent and stable water chamber providing a fast coupling and short untested length.
ERW Solutions: In-Line ERW Tube Inspection System
This in-line quality-control system uses phased array probes to inspect the weld seam and the heat-affected zone (HAZ) of electric resistance welded (ERW) tubes. The head rotation enables each probe to move independently from –120 to +120° for weld tracking.
ERW Solutions: Off-Line ERW Tube Inspection System
The ERW Off-Line uses phased array technology to inspect weld seams and the heat-affected zone (HAZ) of electrical resistance welded (ERW) tubes. Using only one PA probe on each side of the weld provides wide sector coverage of the HAZ with constant amplitude.
ERW Solutions: In-Line ERW High-Temperature Inspection System
This in-line PAUT process-control system is positioned between weld cooling and annealing to inspect ERW tube seams and HAZ. Its unique self-cooling wedge and automatic alarms protect the phased array probe from temperatures up to 100 °C (212 °F).