IPLEX TX II
The ultra-thin IPLEX TX II video borescope is available with a 2.2 mm diameter flexible scope or a 1.8 mm rigid scope. Using the flexible scope, you can obtain a wide field of view in spaces where the opening is very small for faster inspections and easier decision making. Combining high image quality and user comfort, the IPLEX TX II video borescope enables efficient inspection of castings, molds, and other parts with small cavities.
IPLEX TX II Videoscopes and Borescopes
Better Imaging in Small Spaces
The ultra-thin IPLEX TX II video borescope is available with a 2.2 mm diameter flexible scope or a 1.8 mm rigid scope. Using the flexible scope, you can obtain a wide field of view in spaces where the opening is very small for faster inspections and easier decision making. Combining high image quality and user comfort, the IPLEX TX II video borescope enables efficient inspection of castings, molds, and other parts with small cavities.
Repeatable RVI Results
The IPLEX TX II video borescope offers easier insertion to help you reach your target faster as well as improved image quality that supports your decision making.
- Visual Inspection
- Video Borescopes
Unleash the Power of One
IPLEX™ One Videoscope Solution
The 10th generation of the IPLEX videoscope system, IPLEX One is a unified, software-driven platform that empowers you to work faster, see more, and stay ahead. Combining groundbreaking Swoptix 3D measurement technology with viewing and analysis upgrades and modular scalability, IPLEX One redefines what’s possible in remote visual inspection.
IPLEX TX (predecessor)
See More
- 120-degree field of view to observe a wide area at once, helping speed up inspections
- High-pixel CMOS sensor delivers excellent image quality
- Bright LED illumination enables you to see better in large spaces
- Image adjustment methods—like image turning and halation reduction—make it easier to see in reflective areas and capture clear, low-noise images
- Scene mode enables you to create two image setting configurations and toggle between them
IPLEX TX II
Inspect in Smaller Spaces
- Access small openings with the 2.2 mm insertion tube
- Insertion tube with a 2 mm shorter rigid distal end compared to the original IPLEX TX combined with improved hardness and articulation control, making it easier to maneuver in smaller spaces
- The insertion tube’s articulating section has a tungsten outer braid for added protection, while its shortened length help keep it from getting stuck
- The rigid insertion tube's air injector enables you to blow liquid droplets away to obtain clearer images *
*The protection sleeve is required to use the air injector.
Stay Comfortable During Long Inspections
- Ultra-lightweight rigid scope weighs as much as a ballpoint pen, so there’s less strain when you’re holding it for long periods of time
- Extend the grip to grasp the tube closer to the insertion point for finer control
- Images are displayed on a tablet, so you can position it where it’s comfortable
Durable and Flexible
- The flexible insertion tube’s articulation section improves its overall durability
- Metal braiding in the articulation section provides additional protection and wear resistance
- For applications where it’s required, the optional rigid scope enables you to acquire high-quality images and pass through openings as small as 1.8 mm
- With the rigid scope's CMOS imaging sensor, images still transmit to the screen if the tube is slightly damaged
Flexible scope unit
Rigid scope unit
Specifications
Scope Unit
| Model No. | Flexible scope unit: IV10212TF | Rigid scope unit: IV10212TR | |
| Insertion tube | Scope diameter | Φ2.2 mm | Φ1.8 mm |
| Scope length | 1.2 m (3.9 ft) | 180 mm (0.59 ft) | |
| Distal end length*1 | 7.85 mm (0.31 in.) | - | |
| Exterior | High durability metal braid with special processed resin | - | |
| Tube flexibility | Uniform stiffness | - | |
| Optical system | Direction of view | Forward | |
| Field of View | 120° | ||
| Depth of field*2 | 3–80 mm | ||
| Articulation Section | Articulation angle | 135° (up/down) | - |
| Articulation mechanics | Direct manipulation | - | |
Control Unit
| Model No. | IV10200T |
| Weight | 350 g (0.77 lb) |
| Dimensions (L x Φ) | 172 x 52 mm (6.77 × 2 in.) |
| Illumination | High-intensity white LED |
| Power supply | USB power supply |
| USB connector | Type C connector, Version 2.0 standards |
Operation Unit
| Model.NO | IV10-OPERATION |
| Weight | 2.1kg |
| Dimensions (W x H x D) | 300 mm × 230 mm × 49 mm (11.8 in. × 9.1in. × 1.9 in.) (protruding parts not included) |
| LCD Monitor | 10.1-inch WUXGA (1920 × 1200), IPS, High contrast Hard surface and multi-touch interface (10 point), capacitive Daylight readable display (Optical bonding + AR coating) 1100 NIT-backlight |
| Video output | Type A HDMI 2.0 |
| Headset (microphone in/ audio out) | Compatible with Bluetooth® headset/microphone |
| Data I/O Ports | USB Type C Port x3 |
| Power Supply | 100 V to 240 V, 50/60 Hz (with supplied AC adaptor), 10.8V (with supplied battery) |
| Recording media | Internal SSD (256 GB) or USB flash memory |
| Title Text Options | 51-character display |
| Wi-Fi | 2.4GHz (802.11 b/g/n/ax) x 2ch (Built in operation unit) |
| Bluetooth® | Bluetooth® 5.2 × 1 |
Software Functions - IPLEX One App
| Image manipulations | 2x digital zoom, 12-step manual or 8-step auto brightness control | |
| Gain control | 2-step adjustable gain control (manual or auto) | |
| Sharpness control | 3-step adjustable sharpness control | |
| Saturation control | 3-mode adjustable color saturation (monotone, natural, vivid) | |
| Overlay | 51 character title, Zoom,Bright, Light date/time, Scene, Logo, Socpe serial | |
| Still image recording | Resolution | H512 x V512 (Pixel)* *When Print Screen is on, the resolution becomes H1280 × V800. |
| Recording format | Compressed JPEG format, PNG format | |
| Video recording | Resolution | H392 x V392 (Pixel)* *When Print Screen is on, the resolution becomes H1280 × V800. |
| Recording format | MPEG4 AVC/H.264 (.MP4 file) | |
| Frame rate | 30 | |
| Plan | Displays the folder tree and lists thumbnails within the folders | |
| File | Copy, rename, delete, add mark, add title for file Create, copy, rename, delete for folder USB and internal flash storage Inspection data synchronization with Evident Coneect using WiFi |
|
Operating Environment
| Operating temperature | Insertion tube | In air: -25 to 80 °C (-13 to 176 °F), In water: 10 to 30 °C (50 to 86 °F) |
| Other parts | In air: -10 to 40 °C | |
| Relative humidity | All parts | 15 to 90% (Relative Humidity) |
| Liquid resistance | All parts | Operable when exposed to machine oil, light oil, or 5% saline solution. |
| Waterproofing | Insertion tube | Operable underwater up to a water pressure equivalent to a depth of 1.2 m. |
| Other parts | Operable in blowing rain conditions; not operable under water |
*1 Indicates the length of the rigid portion at the scope's distal end.
*2 Indicates the viewing distance with optimal focus.
Accessories
Protection Braid for IV10212TF
| Model No. | MAJ-2537 |
| Weight | 5.6 g |
| Outer diameter | φ2.8 mm (0.1 in.) |
| Braid length | Approx. 1 m (3.3 ft) |
Protection Sleeve for IV10212TR
| Model No. | MAJ-2538 |
| Weight | 2.85 kg (6.3 lb) |
| Outer diameter | φ2.3 mm (0.09 in.) |
| Sleeve length | 160 mm (0.5 ft) |
| Air tube outer diameter | 4 mm |
| Maximum air pressure | 0.7 Mpa |
Grip Extender for IV10212TR
| Model No. | MAJ-2540 |
| Weight | 53 g (total of three) |
| Dimensions (L x Φ) | 30 × 14 mm (1.2 × 0.6 in.), 48 × 14 mm (1.9 × 0.6) |
Protection Box
| Model No. | MAJ-2536 |
| Dimensions (W × D × H) | 400 x 150 x 300 mm (excluding protrusion) |
| Weight | 2.85 kg (6.3 lb) |
| Waterproofing | IP52 dustproof and splashproof |
Carrying Case
| Dimensions (W × D × H) | 455 x 185 x 330 mm (excluding protrusion) |
| Weight | 2.1 kg (5 lb) |
*Indicates the viewing distance with optimal focus.
*The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.
*Evident Corporationuses these trade markes and logos under license. All other trademarks and registered trademarkes are the property of their respective owners.
Tablets Tested for Compatibility
· May not work when combined with other software.
· If you are going to use the IPLEX TX II software with a tablet other than those listed above, please refer to the recommended tablet specifications below.
· If you have any questions, please contact your local Evident representative.
Recommended Tablet Specifications
· We do not guarantee that the IPLEX TX II software will work on all tablets that meet the above criteria.
Software
ViSOL™ Visual Inspection Workflow Solution
Connecting You with More
Streamline your visual inspections with ViSOL. Designed to intuitively organize, analyze, and report inspection data, ViSOL delivers actionable insights with advanced analytics, clear visualization, and seamless collaboration. A fully scalable cloud software solution, ViSOL supports digital transformations for individuals and organizations at any scale.