Aerospace

Industries

Evident Solutions for Aerospace

During the manufacturing and maintenance of aircraft, critical components are inspected to check that they are operating correctly. Inspectors must be familiar with multiple nondestructive technologies, so having equipment that’s versatile and easy to use is important.

From checking the integrity of aircrafts’ aluminum skin with eddy current flaw detectors to using phased array technology for full volumetric inspection of complex composite parts to looking inside jet engines for cracks and other flaws using remote visual inspection videoscopes, our technology helps inspectors keep aircraft operating safely.

Resources

Vanta for Manufacturing QA/QC

Read more

DELTA Alloys and Metals Handheld RXF Analyzer

Read more

Gas Turbine Inspection Solution

Read more

Composite Inspection Solution

Read more

More Resources

Insights

Waveguide Inspection Techniques Using an Ultra-Thin Video Borescope

Read more

4 Reasons Aviation Companies Check Their Engines with the IPLEX™ NX Videoscope

Read more

Locating Cracks on the Space Station—Eddy Current Flaw Detectors with the Right Stuff

Read more

Caring for the Heart of the Aircraft: Videoscope Inspections Help Enhance Flight Safety

Read more

Built to Spec—Evident Delivers on Customized Sensor Solutions

Read more

Which Phased Array Probe Is Right for Your Total Focusing Method Inspection?

Read more

Ruckus Composites Inspects Thousands of Bikes with One Ultrasonic Thickness Gauge

Read more

How to Confirm Videoscope Measurement Points with Confidence

Read more

5 Reasons Pros Will Value WeldSight Software

Read more

3 Ways the OmniScan X3 Flaw Detector’s Scan Plan Tool Simplifies Your Set Up

Read more

ASNT 2018 Wrap Up

Read more

Touch Down: Eddy Current Wheel Probes Help Ensure a Safe Landing

Read more

ECNDT 2018 Wrap Up Part 3: RVI

Read more

EX Series Flaw Detectors for Use in Explosive Atmospheres: FAQs

Read more

5 Ways to Improve Measurement Accuracy with the Magna-Mike 8600 Thickness Gauge

Read more

How To: Add a Coating Model on Your Vanta Analyzer

Read more

Accurate Alloy Analysis

Read more

This Old Videoscope

Read more

What Goes Up, Must Come Down—the EPOCH 6LT Flaw Detector’s Wild Ride

Read more

Through Thick and Thin: Using XRF to Measure Coating Thickness

Read more

Creating a Highly Portable Flaw Detector from the Ground Up

Read more

How to Get Comfortable Finding the Right Frequency on Your Bond Tester

Read more

Tired of Removing Paint to Inspect Welds?

Read more

Did You Know? We Custom Manufacture Probes for Your Specific Applications

Read more

Out of this World: Evident XRD on Mars

Read more

Did You Know? Crystals Are Essential to NDT Transducers

Read more

Bring the Noise! How Sound Helps Keep Airplanes Safe

Read more

4 New Features of the OmniScan® MXU 4.4 Software that Help Speed-Up Inspections

Read more

Advancements in Remote Video Measurement: Get More Precision from Farther Away

Read more

3 Important Considerations when Using X-ray Fluorescence for Positive Material Identification

Read more

IPLEX NX Videoscope Wins Design Award!

Read more

Get the latest on recent advances in portable phased array

Read more

Safety and Speed: Using Remote Video to Inspect a Supersonic Car

Read more

The Advantages of Using Polarized Light to Identify Wear Debris

Read more

Get the Most Out of Your Thickness Gauge with Instructional Videos

Read more

Vanta Handheld XRF Analyzers Outperform the Competition

Read more

Application Notes

Manual Scanning of Fastener and Bolt Holes Using Eddy Current Testing

Read more

Measuring Coating Thickness on Composite Aircraft: From Total Thickness to Individual Layers

Read more

Fastener Hole Crack Detection Using Adjustable Sliding Probes

Read more

Eddy Current Bolt Hole Inspection Using Smart Filter Adjustment

Read more

VDM Metals Exceeds Client Expectations with Vanta™ Handheld XRF

Read more

Phased Array Inspection of Aerospace Fastener Holes

Read more

Inspecting the Internal Structure of Turbine Blades Using Ultra-Thin Videoscopes

Read more

Analyzing Wear Metals and Additives in Oil and Fuel Using the VCA Model Vanta Analyzer

Read more

Using the Vanta™ XRF Analyzer to Quickly and Accurately Sort Low-Magnesium Aluminum Alloys

Read more

Eddy Current Bolt Hole Inspection Smart Filter Adjustment

Read more

Meeting Strict Standards for Sulfur Content in Fuel with Vanta XRF Analyzers

Read more

Videoscope solution for working at heights when inspecting the main rotors of helicopters

Read more

Borescope inspection of helicopter main gear boxes

Read more

High resolution imaging solution for the remote visual inspection of small gas turbine aircraft engines

Read more

A Tip to Save Time in Wind Turbine Inspection

Read more

Corrosion Mapping on Carbon Steel Using the RollerFORM Scanner

Read more

Laminar Cracking in Fiberglass

Read more

Phase Shift Test for Bond Integrity

Read more

Ringdown Test for Bond Integrity

Read more

Videoscope Inspection Using Ultraviolet Dye Penetrant

Read more

Scaling and Corrosion Residue Identification with X-ray Diffraction

Read more

Flexible Ultrasonic Phased-Array Probe for Complex Shape Inspection

Read more

Immersion Flat with Radius (IFWR) Phased Array Probes

Read more

High-Speed Phased Array Ultrasound Inspection of Aerospace Composite Parts

Read more

Manual Phased Array Ultrasound as a Complement to Radiographic Inspections

Read more

Automatic Fastener Hole Inspection in Aircraft

Read more

Measuring Manufactured Plastic Pipes

Read more

ECA Subsurface Crack Detection

Read more

ECA Subsurface Corrosion Detection

Read more

ECA Surface Crack Detection

Read more

Visual Inspections of Commercial Jet Engines

Read more

Void Detection in Molded Plastic Parts

Read more

Reducing the edge effects in turbine component inspections using flexible printed circuit board (PCB) based eddy current array probes.

Read more

Measuring the Quantity of Magnetic Debris Using the Evident Debris Tester

Read more

Inspection of Composite Radii

Read more

Automated QC / PMI Analyzer - For Fast, 100% Testing of Tubes

Read more

Automated Alloy Sorting - Stainless Steel & Specialty Alloys

Read more

Handheld XRF for Light Elements Phosphorus (P) in Steel

Read more

Measuring the Wall Thickness of Small-Diameter Metal and Plastic Tubing

Read more

Aircraft Skin Inspection with Phased Array Lateral Scanning

Read more

Nondestructive Bond Testing for Aircraft Composites

Read more

Aircraft Composite Inspection with 35RDC Ramp Damage Checker

Read more

Corrosion Detection and Measurement Using Eddy Current Methods

Read more

Inspecting Areas Close To Edges

Read more

Ultrasonic Testing in the Foundry Industry

Read more

Ultrasonic Testing of Aluminum and Nonferrous Castings

Read more

Measuring Thickness of Wax Molds for Precision Castings

Read more

Measuring Nodularity in Cast Iron Using Ultrasonic Testing

Read more

Thickness Measurements of Fiberglass Plates, Pipes, and Storage Tanks

Read more

Thickness Measurement of Aerospace Composites

Read more

Measuring Fiberglass Gelcoat Thickness

Read more

Inspection of Composite Rocket Nozzle

Read more

Thickness Measurements on Rubber Hoses and Tubing

Read more

Thickness Measurements on Rubber Sheets and Coatings

Read more

Measuring the Thickness of Rubber Tires

Read more

Measuring the Thickness of Glass Products and Coatings

Read more

Measuring the Wall Thickness of Turbine Blades

Read more

High-Temperature Ultrasonic Testing

Read more

Thickness Measurement of Coextruded Cap Layers

Read more

Thickness Measurements of Polymer Aircraft Windshields

Read more

Inspection of Landing Gear

Read more

Corrosion Thickness Gauging with Dual Element Transducers

Read more

Phased-array Examination of Friction Stir Welds

Read more

Turbine Dovetail Inspection Using Eddy Current Arrays

Read more

Inspection Of Titanium Castings Using Ultrasound Phased Array

Read more

Measuring Metal Thickness through Paint

Read more

Wall Thickness Measurements of Metal Pipes and Tubes

Read more

Ultrasonic Thickness Measurements of Hot Metals

Read more

Measuring Wall Thickness of Gun Drilled Metal

Read more

Metal Coils Thickness Inspection

Read more

Case Studies

Taking Flight with an NDT Level III—Aircraft Inspection Using Eddy Current Testing

Read more

Ruckus Composites Inspects Thousands of Bikes with One Ultrasonic Thickness Gage

Read more

Solutions

Aerospace Inspections Solutions

Read more

Gas Turbine Inspection Solutions

Read more

Corrosion Inspection Solutions

Read more

Vanta for Manufacturing QA/QC

Read more

Composite Inspection Solutions

Read more

Weld Inspection Solutions

Read more

OmniScan MX ECA/ECT

Read more

Phased Array CFRP Inspection

Read more

DELTA Alloys and Metals Handheld XRF Analyzer

Read more

Friction Stir Weld Inspection

Read more

Automated Composite Part Inspection Systems

Read more

White Papers

Use of the Total Focusing Method with the Envelope Feature

Read more

Increasing the Brightness of Industrial Videoscopes

Read more

Multi-mode Adhesive Bond Testing

Read more

Application Considerations in Specifying High Frequency Ultrasonic Transducers

Read more

What are Industrial Videoscopes?

Read more

How to choose optical tip adapters for the industrial videoscopes

Read more

Tutorials

Ultrasonic Flaw Detection Tutorial

Read more

Phased Array Tutorial

Read more

Eddy Current Array Tutorial

Read more

Ultrasonic Thickness Gauge Tutorial

Read more

FAQs

Frequently Asked Transducer Questions

Read more

Product Resources