Benchtop XRF Analyzers

Contact Us

Benchtop X-ray fluorescence (XRF) analyzers are compact and stylish for the consumer showroom environment. Our benchtop XRF analyzers include precious metal analyzers for proving the purity and composition of gold, silver, jewelry, coins, watches, and other valuable objects.

Benchtop XRF analyzers are used by jewelry stores and pawn shops to accurately price the valuables they buy and sell. Using a simple and safe testing process, these analyzers deliver precious metal content, karatage, and fineness in seconds without damaging valuables. Verify authentic jewelry made of gold, silver, palladium, platinum, and other precious metals on the spot.

Another option for benchtop XRF is our dedicated XRF work station. This stable platform turns our analyzers into a benchtop system, providing you with the flexibility to perform hands-free analysis or handheld testing.

Showroom and Benchtop XRF Analyzers

Vanta™ GX Precious Metal Analyzer

Buy and sell gold, jewelry, coins, and other valuables with the highest level of confidence using the Vanta™ GX XRF analyzer. Accurate, easy to use, and nondestructive, this benchtop instrument is a simple and affordable way to determine the purity and composition of gold and other precious metals. Get showroom-ready results at the push of a button.

Learn more about Vanta GX

Benchtop XRF Resources

5 Reasons to Test Jewelry with the Vanta GX Precious Metal Analyzer

Testing jewelry for precious metal content, purity, and karatage should be simple and fast. Our Vanta GX precious metal analyzer takes the guesswork out of jewelry analysis so you can buy and sell gold, jewelry, coins, and other valuables with confidence.

Comparing Gold Testing Methods to Maximize Profits: XRF vs. Acid Scratch vs. Conductivity Testing

Discover the most effective methods for analyzing precious metals such as gold and silver.

Precious Metal Analyzer FAQs

What does a precious metal analyzer cost?
The price of a precious metal analyzer starts at US$ 15,000 and can vary depending on your testing needs. Please contact your local sales representative for more information about our precious metal analyzer models.
What types of items can be tested with a precious metal analyzer?
A precious metal analyzer can test many items, including gold, silver, platinum, palladium, rings, watches, bracelets, brooches, and earrings.
Will the test from a precious metal analyzer damage my items?
No, precious metal analyzers use nondestructive X-ray fluorescence (XRF) testing, a safe and trusted elemental analysis method that will not harm or damage your items. Learn more in our XRF FAQs.
How accurate is XRF testing for metals?

XRF testing is a highly precise and thorough technique used to assess the precious metal content and purity of valuable metals. By emitting X-rays into a metal sample, an XRF analyzer can measure the energy released by excited electrons, enabling it to identify the composition of the material and deliver results within seconds. The accuracy and precision of XRF are demonstrated in the table below:

Vanta GX PIN model (15-second test time, %)

Element Test 1 Test 2 Test 3 Test 4 Test 5 Vanta GX Average (%) FLUXANA 0732-16 Certified Value (%)
Gold (Au) 33.50 33.40 33.39 33.38 33.42 33.42 33.33
Silver (Ag) 58.30 58.41 58.36 58.29 58.41 58.36 58.61
Copper (Cu) 8.2 8.2 8.25 8.32 8.17 8.23 8.06