Notas de aplicación

Contacta con nosotros

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Carbon Steel Weld Inspection

Magnetic particle inspection is used to help monitor the integrity of welded pipes and pressure vessels. This method was used for decades, primarily because of its portability and ease of use. It is a common industry practice to use specifically-designed oil and water-based carriers for magnetic particles, adding extra cost for chemicals and chemical waste disposal. In addition, this method also requires paint removal and repainting, adding additional cost to the inspection.

Eddy current inspection is an economical, nondestructive alternative to magnetic particle inspection. Eddy current inspection is fast, reliable, easy to use, and can inspect directly through painted surfaces. With eddy current, inspectors no longer have to strip and repaint pipes and vessels. As an added feature, eddy current makes it easy to record the defect length and depth.

Benefits of Eddy Current Array for Weld Inspection Compared to Magnetic Particle:

The inspection process using eddy current technology is fast, and the preparation is kept to a minimum—no intensive cleaning or paint removal is required. Eddy current inspection is also effective in most weather conditions including rain, heat, and cold. For easy post-processing analysis and data archiving, setup files can be saved and recalled for the next job. In addition, report files can be easily created directly from the instrument.

New Software Designed for Weld Applications

Eddy Current Array (ECA) Solution — OmniScan® Instruments




Figure 1: The Omniscan MX flaw detector with the MagnaFORM probe.

New ECA Probes Using Dynamic Lift-Off Compensation Technology

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 2: The MagnaFORM probe.




Figure 3: The MagnaFORM probe unassembled.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 4: The probe’s interchangeable wedges.

Ready for Scanners

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 5: Image of MagnaFORM probe mounted on scanner

New Defect Depth Evaluation Tool

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 6: A screen shot of the flaw detector’s measurement tools.

Reliable Defect Detection

The probe’s flexible PCB technology combined with dynamic lift-off compensation technology enables the solution to detect defects in all areas of the weld.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds


Figure 7: The defects located during a weld inspection.

Instant Reporting

The OmniScan MX flaw detector features built-in reporting at the touch of a key. Reports can also be configured and customized by advanced users.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Figure 8: An example of the first page of an OmniScan report.

Eddy Current as an Alternative to Magnetic Particle Inspection for Carbon Steel Welds

Figure 9: The second page of an OmniScan report.

Easy Archiving

Archiving inspection data files is easy, simply press a key during acquisition or analysis to store the data on the instrument’s memory card.




Figure 7: The defects located during a weld inspection.

Productos relacionados

OmniScan X3 Series

Cada detector de defectos de la serie OmniScan™ X3 es una completa caja de herramientas por ultrasonido multielemento (Phased Array). Las innovadoras y avanzadas técnicas TFM y PA permiten identificar defectos con confianza, mientras que las potentes herramientas de software y los sencillos flujos de trabajo mejoran su productividad.

Sondas de corrientes de Foucault multielementos (ECA)

Las sondas de corrientes de Foucault multielementos están destinadas a la detección de corrosión, la inspección de soldaduras por fricción y a la detección superficial y subsuperficial para acelerar el proceso de inspección.

OmniScan MX ECA/ECT

Este equipo efectúa inspecciones por corrientes de Foucault multielementos. La configuración para ensayos soporta hasta 32 bobinas sensoriales (hasta 64 usando un multiplexor externo) bajo los modos de puente o emisión-recepción. La frecuencia de funcionamiento varía entre 20 Hz y 6 MHz, con la posibilidad de utilizar múltiples frecuencias en el curso de una misma adquisición.