Videoscope solution for working at heights when inspecting the main rotors of helicopters

Videoscope solution for working at heights when inspecting the main rotors of helicopters

Application—Borescope inspection of helicopter main rotors

During maintenance of helicopters, inspectors use industrial borescopes to check for any damage or cracks in the strap pack located at the base of the main rotor. As the main rotor of the helicopter is located at the top part of the airframe, inspectors often use scaffolding or a platform to access it. If the instrument is small enough, inspectors can place it on the platform or scaffolding. Sometimes they rest the instrument on top of the airframe, but depending on the helicopter model, there may not be enough room. Limited space often forces inspectors to hold the inspection instrument in one hand and maneuver the borescope in the other. However, holding it in one hand can be cumbersome and even painful if the instrument is heavy.

Evident’ IPLEX G Lite videoscope in use on a platform
Evident’ IPLEX G Lite videoscope in use on a platform

Solution Using the IPLEX G Lite Industrial Videoscope

Evident’ IPLEX G Lite industrial videoscope was designed for one-handed operation. It enables inspectors to perform remote visual inspection of motor rotors in restrictive workspaces where their only choice is to hold the instrument for the entire duration.

IPLEX G Lite videoscope
IPLEX G Lite videoscope

  1. You can hold it comfortably with one hand for extended periods.
    The touch screen and control unit of an IPLEX G Lite videoscope is not only lightweight but also optimally weight balanced, so the load is easier to bear.
  2. All operations can be easily performed with one hand.
    The IPLEX G Lite videoscope is equipped with ambidextrous controls that enable you to perform all operations with one hand, including image recording/playing, articulating the tip of the scope, as well as other menu prompts.
  3. The only cable is the insertion unit.
    The videoscope controls are integrated into the handheld unit along with the touch-screen monitor. It is battery operated, so no power cable is required.

Conclusion

The IPLEX G Lite videoscope can be held easily with one hand during the entire duration of remote-visual inspections of helicopter rotor motors, enabling inspectors to get reliable and accurate images and results, even in the restrictive and elevated working conditions of scaffolding and platforms.

Productos para la aplicación


https://main--eds-evident-website--evident-scientific.aem.live/es/rvi-products/iplex-nx/

IPLEX NX

Este sistema videoscópico industrial de última generación engloba portabilidad, funciones avanzadas, facilidad de uso y durabilidad. Desde imágenes de alta calidad hasta operaciones de subsanación, la versatilidad de este videoscopio proporciona varios beneficios que van más allá de la experiencia.

IPLEX G Lite/G Lite-W

El videoscopio industrial IPLEX G Lite ofrece potentes capacidades de procesamiento de imágenes en una estructura pequeña y robusta. Gracias a su estructura ligera y diseño que permiten llevarlo a casi cualquier lugar, los usuarios que trabajan en aplicaciones complejas pueden ahora contar con una herramienta de inspección visual que ofrece calidad de imagen y facilidad de uso para ejecutar su trabajo apropiadamente.

Si está inspeccionado los reducidos intersticios de un chasis (chasises) principal de aerogenerador, su trabajo podría ser mucho más fácil gracias a la versión eólica del videoscopio IPLEX G Lite que combina portabilidad y potentes funciones de procesamiento de imágenes.