Portable XRD for Bauxite: Exploration, Mining, and Extraction
Benefits of Evident
The benefits of Evident' innovative pXRD analyzers include:
- Small sample: requires only 15 mg of material
- Easy sample preparation: does not require a skilled technician
- Fast acquisition time: obtain results in few minutes
- Portability: battery operated, rugged design with no moving parts
- Stand-alone instrument: no need for water cooling or a large, external power source
- No ongoing servicing requirements: XRD can be performed regularly without minimal downtime
Exploration
Bauxite comprises numerous aluminum-bearing minerals (e.g. boehmite, gibbsite, diaspore, kaolin) that exhibit varying degrees of metal recovery. Aluminum that can be recovered during processing is referred to as available alumina. Silica that consumes acid during processing is called reactive silica.
Knowing the amount of available alumina and reactive silica is integral to running an efficient and productive operation. By utilizing an Evident pXRD instrument, the geologist can quickly determine available alumina and reactive silica in the field to assess the viability of a bauxite deposit (Figure 1).
Figure 1. Excellent correlation between available alumina and reactive silica as measured by a lab compared to estimates from quantitative pXRD.
Mineral Processing and Extraction
Although important, the bomb digest method (used to determine the amount of available alumina and reactive silica) does not tell you exactly how ore will perform during the refining process. Ore and gangue mineralogy have a large impact on the amount of alumina recovered at the refinery.
Detailed mineralogical modelling and blending strategies can deliver significant project optimization, helping ensure that the best ore product is delivered to the refinery.
Marketing Bauxite Ore
Extraction processes at every refinery are slightly different, so many bauxite producers work to differentiate themselves from competitors. Regular quantitative mineralogical analysis using pXRD can be used as a marketing tool for potential buyers.
Evident pXRD — Data quality and runtime performance
While Evident pXRD analyzers provide the convenience of quantitative mineralogy onsite, without the need for complicated sample preparation procedures, users can also be confident in the results they obtain. To illustrate the quantitative capabilities of Evident pXRD analyzers, we compared results obtained using a large, 4 kW, conventional lab-based instrument. Figure 2 and Table 1 (below) illustrate this these results and show excellent agreement between our pXRD instrument and a lab-based instrument.
Runtime analysis was also carried out to assess the performance of the Evident pXRD analyzers at varying runtimes, and this is shown in Figures 3 and 4 below.
Figure 2. Excellent correlation between mineral percentages via XRD from a lab-based, 4 kW XRD instrument and Evident pXRD with 20 minute runtimes.
Figure 3. XRD traces obtained from a lab-based, 4 kW XRD instrument and Evident pXRD at varying collection times. Please refer to the legend in Figure 4.
Figure 4. Comparisons between mineral percentages deduced from the XRD traces in Figure 3. Note the excellent relationship between the Evident pXRD and labbased instrument, even at short runtimes.