Thickness Measurements on Rubber Sheets and Coatings

Rubber sheets and coatings can be difficult to gauge with conventional mechanical thickness measurement techniques. However, ultrasonic thickness gauging enables measurements on any point on the surface of a rubber sheet—not just the edges—without contacting the opposite side. Ultrasound waves travel through the rubber coating and reflect from the acoustic interface of the rubber and the substrate. This acoustic interface can be air, rubber steel, rubber composite, or other materials as long as the outside surface of the rubber is available for probe coupling.

It is important to fully understand the application before taking thickness measurements. Rubber coating on certain materials may require special setups to maintain accurate thickness readings.

Ultrasonic Equipment Used for Thickness Measurements on Rubber Sheets

Ultrasonic thickness measurements on rubber sheets can be performed using precision thickness gauges, such as the 39DL PLUS™ gauge and the 45MG gauge with Single Element software. When combined with the appropriate transducers between 2.25 MHz and 20 MHz, these handheld gauges can typically measure rubber materials in the range of 0.008 to 0.250 in. (0.2 to 6 mm). This range will vary depending on the transducer and setup being used. Thick or attenuating rubber materials will require the High Penetration software option for the 39DL PLUS and 45MG gauges.

The 72DL PLUS™ gauge offers a larger touch-screen display and a higher measurement update rate (up to 2 KHz). This gauge is available in a high-frequency version (up to 125 MHz) for measuring very thin rubber coatings. It can measure much thinner materials than conventional ultrasonic thickness gauges.


https://main--eds-evident-website--evident-scientific.aem.live/en/39dl-plus/

39DL PLUS

The 39DL PLUS™ gauge is field-proven and reliable for virtually every ultrasonic thickness inspection. It works as a precision or corrosion thickness gauge to meet the challenges of demanding applications across industries, including maintenance, manufacturing, and energy production. With world-class ultrasonic capability, fast scanning speeds, and fully integrated wireless connectivity, this handheld gauge delivers results you can trust in a seamless workflow.


https://main--eds-evident-website--evident-scientific.aem.live/en/72dl-plus/

72DL PLUS

The 72DL PLUS™ advanced ultrasonic thickness gauge delivers precision thickness measurements at high speed in a portable, easy-to-use device. Compatible with single element transducers up to 125 MHz, this innovative instrument is ideally suited to measure the thickness of ultra-thin materials, including multilayer paint, coatings, and plastic. It can simultaneously display the thickness of up to 6 layers.


https://main--eds-evident-website--evident-scientific.aem.live/en/45mg/

45MG

The handheld 45MG ultrasonic thickness gauge is packed with measurement features and software options. This unique instrument is compatible with the complete range of Evident dual element and single element transducers, making this gauge an all-in-one solution for virtually every thickness gauge application.


https://main--eds-evident-website--evident-scientific.aem.live/en/magna-mike8600/

Magna-Mike 8600

The Magna-Mike™ 8600 Hall-effect thickness gauge uses a magnetic probe to accurately measure the thickness of nonferrous and thin materials such as plastic bottles.