Application Notes

Contattaci

Using Eddy Current Array to Detect Corrosion Pitting in Stainless Steel Tubing

Corrosion Pitting Detection

For decades, radiography was the primary method used to detect corrosion in the stainless steel pipes on off-shore platforms. As regulations governing the use of X-rays continue to tighten, radiographic testing (RT) is no longer permitted in some countries.

When inspectors use radiography, there are strict rules about how close people can come to the X-ray equipment, and these regulations are very expensive for the industry. Another issue is the use of radiography in environments where inspectors have to use ropes to access the area. In these instances, inspectors cannot stay close to the radiography tube, so the inspector has to travel back and forth between a safe area and the inspection areas. A third problem with RT is that inspectors need to take multiple shots of the pipe in order to accurately measure the depth of any corrosion, adding time and cost to the analysis.

The Benefits of Eddy Current Array for Sub-Surface Inspection as Compared to Radiography:

Using ECA technology for corrosion detection and depth sizing keeps the surface preparation to minimum. Pipes can be inspected very quickly, and the inspector only needs to travel to the pipe once and then make four passes with the instrument to scan each pipe section. The flaw detection is easy to calibrate and the data acquisition speed is very fast. A set up file can be saved and is easily recalled for the next job while data recording enables seamless post-processing analysis and data archiving. Report files can be easily created directly from the instrument.

Equipment Used

ECA solution – Probes

Reliable Corrosion Detection

Depth Corrosion Measurement

A Variety of Familiar Color-Palette Choices

The MXE 3.0 ECA software features a range of color-palette representations that replicate the look of traditional NDT methods and facilitate the intuitive display of ECA signals.

Instant Reporting

The OmniScan MX features built-in reporting at the touch of a key. Reports can also be configured and customized by advanced users.

Easy Archiving

Archiving inspection data files is also very easy; simply press a key during acquisition or analysis to instantly store the data on the instrument’s memory card.

Prodotti per l'applicazione

OmniScan MX ECA/ECT

Progettato per l'ispezione eddy current. La configurazione dell'ispezione supporta 32 bobine della sonda (fino a 64 con un multiplexer esterno) che vengono usati in modalità ponte o trasmissione-ricezione. Le frequenze operative vanno da 20 Hz a 6 MHz con la possibilità di usare frequenze multiple nella stessa acquisizione.