Application Notes

Contattaci

Non-Destructive Gold Assay Karat ID

gold assay XRF product

Get fast, accurate, analysis results with Handheld XRF. Within seconds, DELTA handheld XRF provides alloy chemistry and karat classification with one non-destructive and non-intrusive test.

With the current high value of gold, quantifying its fineness and purity is more critical than ever. Whether importing precious metals, selling or producing jewelry, fabricating metal, or recycling scrap metal, you need a fast, highly accurate way to determine karatage (gold content) for quality control, pricing, and usage purposes.

The DELTA Classic handheld XRF analyzer not only provides these qualities, but is a non-destructive, cost-effective method to check for gold content and verify alloy chemistry.

XRF is a widely-used, proven and accepted method to generate a complete analysis of gold samples, including purity and fineness. On-the-spot analysis of your gold products and materials is an easy way to boost customer confidence and ensure dealer reliability.

Critical Applications

The DELTA Classic is ideal for the jewelry industry, museums, archaeological sites,
pawn shops, coin collectors, cash-for-gold operations, scrap recycling.

Handsfree testing chamberr Delta Gold XRF
Optional hands-free WorkStation - provides optimal testing conditions for jewelry analysis.
Includes PC software for benchtop-syle analyzer controls.

Features

Performance You Can Count On

In an economic environment where fast AND accurate results are more important than ever, the DELTA Classic handheld XRF provides superior precision and accuracy.

While you benefit from the convenience of easy, on-the-spot analysis with Handheld XRF, you can feel confident in results that will help assure maximum profit for your gold assets.

Gold Data Chart

Repeat Analyses of Gold Alloys

DELTA Classic, 30 sec analysis time

Repeat Analyses of Gold Alloys

Testing screen for Delta

In Focus and On Target for Every Shot

The DELTA Classic is available with optional integrated camera and smalll spot collimation. A CMOS camera records sample images to memory with analysis results for report generation. X-ray beam collimation is utilized for measurement of small components and samples. A simple press of a button activates 3mm diameter collimation; an on-screen indicator shows the operator exactly where the analysis spot is focused. Collimation can be easily reverted to 10mm spot diameter for standard, bulk analyses.

gold assay soft shot karat
gold assay soft shot karat element

Prodotti per l'applicazione

Gli analizzatori XRF portatili DELTA per le leghe e i metalli

Gli analizzatori XRF portatili DELTA PMI realizzano delle analisi non distruttive di leghe per identificare le qualità di lega e misurare la composizione dei metalli in modo rapido e preciso. Eseguono delle ispezioni PMI e delle analisi QA/QC in pochi secondi: dalla semplice identificazione della qualità di lega al controllo qualità di dettaglio, dall'ispezione del materiale in ricevimento alla verifica del prodotto finale.

Analizzatore XRF portatile DELTA per gli scarti metallici

Gli analizzatori XRF portatili DELTA per gli scarti metallici identificano in modo affidabile la maggior parte delle qualità di lega e di metalli puri in un paio di secondi o addirittura meno. Sono progettati per resistere agli ambienti più difficili. È possibile effettuare la cernita di leghe e analisi affidabili per numerosi materiali ferrosi e non ferrosi in qualche secondo.

DELTA Element

Il DELTA Element è un analizzatore a raggi X a fluorescenza (XRF) portatile ed economico, ottimizzato per la cernita di scarti metallici, l'Identificazione positiva dei materiali (PMI), le operazioni di QA/QC delle leghe e le analisi di metalli preziosi.

DELTA Professional

Il DELTA Professional dotato di un rilevatore SDD e un tubo a raggi X ottimizzato da 4 W, assicura performance superiori per la velocità, i limiti di rilevamento o lo spettro elementare. Permette l'analisi del Mg e degli elementi a maggior numero atomico nelle leghe e nei minerali. Il DELTA Professional rappresenta la soluzione Evident a maggior valore aggiunto per gli analizzatori XRF.