ECA 표면 균열 감지

Evident propels eddy current technology into uncharted territory in the aerospace industry, with an innovative surface crack detection solution for lap-splice inspection. The structure of an aircraft contains thousands of fasteners, so ensuring their integrity can be an arduous process. Conventional inspection techniques are typically very time consuming and the probability of detection is highly dependant on operator skill. Nevertheless, for over a decade the technology has remained relatively stagnant ... until now.

Using eddy current array considerably reduces the duration of an inspection, and detection probability is increased. This solution not only saves man-hours, but its streamlined inspection process helps minimize the possibility for error.

Features

High Resolution Scan

The recommended ECA probe, the SBBR-026-300-032, is 26 mm (1 in.) wide and features 32 coils arranged in two rows. This configuration provides increased resolution and clear imagery, which is suitable for very high resolution scans. Its small coils (1.6 mm diameter) and high frequency (80–1000 kHz) allows operators to detect very minute cracks. It can also be used to scan through thin coatings, including standard paint thicknesses. Crack orientation is irrelevant for this probe, as its detection is omnidirectional. Scanning is also effective over ferromagnetic fasteners.

Sonde_CFA_SBBR026_05.psd

SBBR026-ENC probe kit

Scan Through Thick Coating

Another probe is available that can scan fasteners through thick non-conductive coating: the SEB-064-005-032. Though it does not provide high resolution like the SBBR-026-300-032, its low-frequency range (0.5–50 kHz) and bigger coils can scan through thicker, nonconductive coatings like paint, stickers, and rubber. Due to its large coverage (64 mm), two rows of fasteners can be scanned at one time. And, cracks do not have to be oriented in a specific direction, as this probe is also omnidirectional.

Intuitive imagery

Sample with EDM notch

C-Scan

Performance for different notch lengths

Omnidirectional detection

OS_ECA_Rivetcrack_23B.psd

OS_ECA_Rivetcrack_22.psd

No coating

OS_ECA_Rivetcrack_22.psd

2.5 mm of nonconductive coating

Sonde_CFA_SAB064_04.psd

SEB064-ENC probe kit

이 애플리케이션에 사용되는 제품


https://main--eds-evident-website--evident-scientific.aem.live/ko/omniscan-eca/

옴니스캔 MX ECA/ECT

와전류 배열 시험 검사를 수행합니다. 테스트 구성은 브리지 또는 송수신 모드에서 작동하는 32개의 센서 코일(외부 멀티플렉서 사용 시 최대 64개)을 지원합니다. 동작 주파수는 20Hz에서 6MHz까지이며, 동일한 수집에서 여러 주파수를 사용할 수 있습니다.